Heat pump ratings explained

Four numbers decide how much a heat pump costs to run. Here is what each one measures, and where certified models actually land.

SEER2: seasonal cooling efficiency

Cooling output over a typical season divided by the electricity used, in BTU per watt-hour. A 20 SEER2 unit uses about 28% less electricity for the same cooling as a 14.3 SEER2 unit.

Federal minimum (split heat pump)14.3
Bottom quarter of certified models17.5 or less
Median certified model20.0
Top 10%25.0 or more

EER2: cooling efficiency on a hot day

Measured at a single 95°F outdoor condition. It matters most in hot, dry climates where the system runs flat out through the afternoon, and for utilities worried about peak demand.

HSPF2: seasonal heating efficiency

Heating output over a season divided by electricity used. The test assumes a moderate climate, so it says little about performance during a cold snap.

Federal minimum (split heat pump)7.5
Bottom quarter of certified models8.8 or less
Median certified model9.7
Top 10%11.5 or more

Capacity and COP at 5°F

A heat pump loses capacity as it gets colder outside. Capacity at 5°F tells you how much heat is left; COP at 5°F tells you how efficiently it is made (a COP of 2 is twice as efficient as a baseboard heater). ENERGY STAR's cold-climate label requires a COP of at least 1.75 and at least 70% of rated capacity at 5°F.

See the cold-climate models

Why one unit has many ratings

Ratings belong to a matched system - an outdoor unit plus a specific indoor unit, and sometimes a furnace. The same condenser can be certified with dozens of indoor units, each with its own SEER2 and HSPF2. Every certified combination has an AHRI reference number; ask your installer for it.

Questions3
What is a good SEER2 rating?
Across all ENERGY STAR heat pumps in our database, the median is 20.0 SEER2 and the top 10% reach 25.0 or more. The federal minimum for split-system heat pumps is 14.3 SEER2.
What is a good HSPF2 rating?
The median certified heat pump is rated 9.7 HSPF2 and the top 10% reach 11.5 or more. The federal minimum for split systems is 7.5 HSPF2.
What is the difference between SEER and SEER2?
SEER2 replaced SEER in January 2023. The M1 test procedure behind it uses higher external static pressure, closer to real ductwork, so the same unit scores lower: roughly SEER2 ≈ SEER × 0.95 for ducted systems.