HVAC Rated

48,000 BTU mini-split heat pump · ACIQ

ACIQ ACIQ-48ZPL-HP230B

Below average cooling efficiency and very good heating efficiency for a 48,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #136 of 146 48,000 BTU mini-splits for cooling efficiency, and costs about $1,271 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Below average · beats 2%
HSPF2
12.0 Heating efficiency over a season
Very good · beats 89%
EER2
14.0 Cooling efficiency on a 95°F day
Very good · beats 82%
Heat at 5°F
50,000 BTU/h96% of its 47°F output
Average · beats 59%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 50,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 89% of mini-splits.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 15 certified pairings.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications48,000 BTU, R-410A
General
BrandACIQ
Also sold asDIYCOOL, 1HVAC, PolarWave, STEALTH
Outdoor unit modelACIQ-48ZPL-HP230B
SeriesACIQ
TypeMini-split heat pump
Nominal size48,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceOctober 1, 2022
Last certifiedMay 28, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 16.8-17.0)
EER2Efficiency at 95°F outdoors8.2-14.0
Cooling capacity48,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.8-12.0
Capacity at 47°F51,000-53,000 BTU/h
Capacity at 17°F35,000-50,000 BTU/h
Capacity at 5°F48,000-50,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-2.02
ENERGY STAR cold climateYes
Heating output as it gets colder96% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ACIQ-48CD-HH-MB at the standard test temperatures, in BTU/h:

Certified matchups15 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
ACIQ-48CD-HH-MB 1HVAC17.014.012.050,000210857302
ACIQ-48CD-HH-MB STEALTH17.014.012.050,000212316192
ACIQ-48CD-HH-MB DIYCOOL17.014.012.050,000210857342
ACIQ-48CD-HH-MB17.014.012.050,000210857322
ACIQ-48CD-HH-MB PolarWave17.014.012.050,000212316106
ACIQ-48FM-HH-MB · cold climate17.08.29.849,000210857325
ACIQ-48FM-HH-MB DIYCOOL · cold climate17.08.29.849,000210857345
ACIQ-48FM-HH-MB 1HVAC · cold climate17.08.29.849,000210857305
ACIQ-48FM-HH-MB PolarWave · cold climate17.08.29.849,000212316109
ACIQ-48FM-HH-MB STEALTH · cold climate17.08.29.849,000212316195
ACIQ-48CC-HH-MB DIYCOOL · cold climate16.88.310.748,000210857340
ACIQ-48CC-HH-MB · cold climate16.88.310.748,000210857320
ACIQ-48CC-HH-MB 1HVAC · cold climate16.88.310.748,000210857300
ACIQ-48CC-HH-MB PolarWave · cold climate16.88.310.748,000212316104
ACIQ-48CC-HH-MB STEALTH · cold climate16.88.310.748,000212316190
Yearly running cost in 10 large cities$1,154-$2,893

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the ACIQ ACIQ-48ZPL-HP230B?
The ACIQ ACIQ-48ZPL-HP230B is rated at up to 17.0 SEER2 and 14.0 EER2 for cooling and up to 12.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 15 certified matchups SEER2 ranges from 16.8-17.0.
Is the ACIQ ACIQ-48ZPL-HP230B good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 50,000 BTU/h at 5°F with a COP of 2.02, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the ACIQ ACIQ-48ZPL-HP230B cost to run per year?
At its rated efficiency it costs about $1,154-$2,893 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,536 in Phoenix and $2,350 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the ACIQ ACIQ-48ZPL-HP230B?
ENERGY STAR lists 15 certified combinations for this outdoor unit. The highest-rated ones use 1HVAC ACIQ-48CD-HH-MB, STEALTH ACIQ-48CD-HH-MB, DIYCOOL ACIQ-48CD-HH-MB.
What refrigerant does the ACIQ ACIQ-48ZPL-HP230B use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,479/yrYou save $1,061/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump ACIQ ACIQ-48ZPL-HP230B
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,479
Current system, per year
$2,540
You save per year
$1,061
Payback
17.0 years
Net after 10 years
-$7,388

Cooling $994Heating $485Electricity used: 9,245 kWhSaved vs. a minimum-efficiency heat pump: $479

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 48,000 BTU models

See all 146 48,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 28, 2026. How we use the data.