15,000 BTU mini-split heat pump · M-Series
American Standard / Mitsubishi Electric NAXSPB15B112A
Average cooling efficiency and below average heating efficiency for a 15,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #22 of 62 15,000 BTU mini-splits for cooling efficiency, and costs about $391 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.3 Cooling efficiency over a seasonAverage · beats 53%
- HSPF2
- 9.9 Heating efficiency over a seasonBelow average · beats 35%
- EER2
- 14.0 Cooling efficiency on a 95°F dayVery good · beats 82%
- Heat at 5°F
- 19,400 BTU/h121% of its 47°F outputAverage · beats 48%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 19,400 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You mainly need heat - its HSPF2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | American Standard / Mitsubishi Electric |
| Outdoor unit model | NAXSPB15B112A |
| Series | M-Series |
| Type | Mini-split heat pump |
| Nominal size | 15,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | December 1, 2022 |
| Last certified | March 13, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.3 (range 22.3) |
| EER2Efficiency at 95°F outdoors | 14.0 |
| Cooling capacity | 14,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.9 |
| Capacity at 47°F | 16,000 BTU/h |
| Capacity at 17°F | 10,000 BTU/h |
| Capacity at 5°F | 19,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NAXWPH15B112AA at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| NAXWPH15B112AA · cold climate | 22.3 | 14.0 | 9.9 | 19,400 | 206195827 |
Yearly running cost in 10 large cities
- Phoenix, AZ$392/yr
- Miami, FL$298/yr
- Houston, TX$352/yr
- Atlanta, GA$391/yr
- Los Angeles, CA$388/yr
- New York, NY$976/yr
- Chicago, IL$801/yr
- Denver, CO$672/yr
- Seattle, WA$418/yr
- Minneapolis, MN$835/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the American Standard / Mitsubishi Electric NAXSPB15B112A?
- The American Standard / Mitsubishi Electric NAXSPB15B112A is rated at up to 22.3 SEER2 and 14.0 EER2 for cooling and up to 9.9 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the American Standard / Mitsubishi Electric NAXSPB15B112A good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 19,400 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the American Standard / Mitsubishi Electric NAXSPB15B112A cost to run per year?
- At its rated efficiency it costs about $298-$976 a year in electricity in large U.S. cities, depending on climate and local rates - for example $392 in Phoenix and $835 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the American Standard / Mitsubishi Electric NAXSPB15B112A?
- ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses NAXWPH15B112AA.
- What refrigerant does the American Standard / Mitsubishi Electric NAXSPB15B112A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 15,000 BTU models
- Mitsubishi Electric MUZ-FS15NA · cold climate22.3 SEER2 · 10.4 HSPF2
- Mitsubishi Electric MUZ-FS15NAH · cold climate22.3 SEER2 · 9.9 HSPF2
- Midea MO1HS-H15B-2A · cold climate22.2 SEER2 · 11.5 HSPF2
- Panasonic CU-XZ15AKUAC · cold climate22.4 SEER2 · 12.0 HSPF2
- Mitsubishi Electric MUZ-GX15NL · cold climate22.2 SEER2 · 11.0 HSPF2
- Panasonic CS-XZ15AKUAW/CU-XZ15AKUAC · cold climate22.4 SEER2 · 12.0 HSPF2
- Mitsubishi Electric MUFZ-KJ15NAHZ22.2 SEER2 · 10.7 HSPF2
- Mainline ML15HP230NEXH-O · cold climate22.7 SEER2 · 10.2 HSPF2
See all 62 15,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 13, 2025. How we use the data.