9,000 BTU mini-split heat pump · 4DH SERIES
Armstrong Air 4DHV2S09S-1L
Below average cooling and heating efficiency for a 9,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #292 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $264 a year to run in a mixed climate like Atlanta.
- SEER2
- 21.5 Cooling efficiency over a seasonBelow average · beats 39%
- HSPF2
- 9.1 Heating efficiency over a seasonBelow average · beats 13%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- 7,000 BTU/h70% of its 47°F outputVery good · beats 74%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 7,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 13 certified pairings.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
- You mainly need heat - its HSPF2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Armstrong Air |
| Also sold as | ALLIED, Ducane, Concord, AIREASE |
| Outdoor unit model | 4DHV2S09S-1L |
| Series | 4DH SERIES |
| Type | Mini-split heat pump |
| Nominal size | 9,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 1, 2022 |
| Last certified | May 12, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 21.5 (range 21.5) |
| EER2Efficiency at 95°F outdoors | 12.5 |
| Cooling capacity | 9,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.1 |
| Capacity at 47°F | 10,000 BTU/h |
| Capacity at 17°F | 6,300 BTU/h |
| Capacity at 5°F | 7,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.16 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with DWH209S4-*L at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| DWH209S4-*L · cold climate | 21.5 | 12.5 | 9.1 | 7,000 | 211034539 |
| DWH209S4-*L Allied · cold climate | 21.5 | 12.5 | 9.1 | 7,000 | 211034513 |
| DWH209S4-1L · cold climate | 21.5 | 12.5 | 9.1 | 7,000 | 208106740 |
| DWH209S4-1L CONCORD · cold climate | 21.5 | 12.5 | 9.1 | 7,000 | 208106751 |
| DWH209S4-1L Allied · cold climate | 21.5 | 12.5 | 9.1 | 7,000 | 208106707 |
| DWH209S4-1L · cold climate | 21.5 | 12.5 | 9.1 | 7,000 | 208106740 |
| DWH209S4-1L AirEase · cold climate | 21.5 | 12.5 | 9.1 | 7,000 | 208106729 |
| DWH209S4-1L DUCANE · cold climate | 21.5 | 12.5 | 9.1 | 7,000 | 208106718 |
| DWH209S4-1L Allied · cold climate | 21.5 | 12.5 | 9.1 | 7,000 | 208106707 |
| DWH209S4-*L AirEase · cold climate | 21.5 | 12.5 | 9.1 | 7,000 | 211034487 |
| DWH209S4-*L CONCORD · cold climate | 21.5 | 12.5 | 9.1 | 7,000 | 211034565 |
| DWH209S4-*L DUCANE · cold climate | 21.5 | 12.5 | 9.1 | 7,000 | 211034591 |
| DWH209S4-1L DUCANE · cold climate | 21.5 | 12.5 | 9.1 | 7,000 | 208106718 |
Yearly running cost in 10 large cities
- Phoenix, AZ$263/yr
- Miami, FL$199/yr
- Houston, TX$237/yr
- Atlanta, GA$264/yr
- Los Angeles, CA$263/yr
- New York, NY$662/yr
- Chicago, IL$543/yr
- Denver, CO$456/yr
- Seattle, WA$284/yr
- Minneapolis, MN$567/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Armstrong Air 4DHV2S09S-1L?
- The Armstrong Air 4DHV2S09S-1L is rated at up to 21.5 SEER2 and 12.5 EER2 for cooling and up to 9.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Armstrong Air 4DHV2S09S-1L good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 7,000 BTU/h at 5°F with a COP of 2.16, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
- How much does the Armstrong Air 4DHV2S09S-1L cost to run per year?
- At its rated efficiency it costs about $199-$662 a year in electricity in large U.S. cities, depending on climate and local rates - for example $263 in Phoenix and $567 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Armstrong Air 4DHV2S09S-1L?
- ENERGY STAR lists 13 certified combinations for this outdoor unit. The highest-rated ones use DWH209S4-*L, Allied DWH209S4-*L, DWH209S4-1L.
- What refrigerant does the Armstrong Air 4DHV2S09S-1L use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 9,000 BTU models
- Arcoaire D5CERAH09AAJ · cold climate21.5 SEER2 · 9.1 HSPF2
- Carrier 37MHRAQ09AA1 · cold climate21.5 SEER2 · 9.1 HSPF2
- MDV MOX230-09HFN1-MT0W-L · cold climate21.5 SEER2 · 9.4 HSPF2
- Cooper&Hunter CH-NY09MIA-115VO · cold climate21.5 SEER2 · 9.1 HSPF2
- Midea MO1BS-H09B-2A · cold climate21.6 SEER2 · 9.4 HSPF2
- Kepler ODUMOX230-09HFN1-BS5W · cold climate21.5 SEER2 · 9.1 HSPF2
- CanAir 4C22SCH09H21 · cold climate21.6 SEER2 · 9.4 HSPF2
- Lennox MHB009S4S-1L · cold climate21.5 SEER2 · 9.1 HSPF2
See all 395 9,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 12, 2026. How we use the data.