2-ton central heat pump · A7SCP18V Series
Armstrong Air A7SCP18V24P-**A
Very good cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.
Ranks #87 of 331 2 ton central heat pumps for cooling efficiency, and costs about $652 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.5 Cooling efficiency over a seasonVery good · beats 77%
- HSPF2
- 10.0 Heating efficiency over a seasonVery good · beats 84%
- EER2
- 12.3 Cooling efficiency on a 95°F dayVery good · beats 76%
- Heat at 5°F
- 23,400 BTU/h92% of its 47°F outputBelow average · beats 12%
A good fit if…
- You want low cooling bills - its SEER2 beats 77% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 23,400 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Armstrong Air |
| Also sold as | AIREASE |
| Outdoor unit model | A7SCP18V24P-**A |
| Series | A7SCP18V Series |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 25, 2024 |
| Last certified | July 16, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.5 (range 15.2-18.5) |
| EER2Efficiency at 95°F outdoors | 11.0-12.3 |
| Cooling capacity | 23,200-24,200 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.5-10.0 |
| Capacity at 47°F | 23,800-24,800 BTU/h |
| Capacity at 17°F | 18,000-20,200 BTU/h |
| Capacity at 5°F | 20,000-23,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.75-1.85 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7AH2AE30PX- at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 268 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 7AH2AE30PX- · cold climate | - | 18.5 | 12.3 | 9.8 | 22,000 | 216705378 |
| 7AH2AE30PX- · cold climate | - | 18.5 | 12.3 | 9.8 | 22,000 | 216705385 |
| 7AH1AV24PX- · cold climate | - | 18.0 | 11.7 | 10.0 | 23,000 | 216010755 |
| 7AH1AV24PX- · cold climate | - | 18.0 | 11.7 | 10.0 | 23,000 | 216013460 |
| 7AH2AV30PXC- · cold climate | - | 18.0 | 12.0 | 9.5 | 22,600 | 216619019 |
| 7AH2AV30PXC- · cold climate | - | 18.0 | 12.0 | 9.5 | 22,600 | 216618963 |
| 7AH1RE30DX- · cold climate | - | 17.9 | 11.8 | 9.9 | 22,600 | 218636337 |
| 7AH1RE18DX- · cold climate | - | 17.9 | 11.9 | 9.9 | 22,600 | 218636335 |
| 7AH1RE30DX- · cold climate | - | 17.9 | 11.8 | 9.9 | 22,600 | 218636328 |
| 7AH1RE18DX- · cold climate | - | 17.9 | 11.9 | 9.9 | 22,600 | 218636326 |
| 7EH30AX-**+TDR · cold climate | A80UH2E045A12* | 17.9 | 12.0 | 9.5 | 20,600 | 217188679 |
| 7EH30AX-**+TDR · cold climate | A80UH2E045A12* | 17.9 | 12.0 | 9.5 | 20,600 | 217188929 |
| 7AH1RE24DX- · cold climate | - | 17.8 | 11.8 | 9.9 | 22,600 | 218636336 |
| 7AH1RE24DX- · cold climate | - | 17.8 | 11.8 | 9.9 | 22,600 | 218636327 |
| 7E[C,U]36AX-**+TDR · cold climate | A80UH2E045A12* | 17.8 | 12.0 | 9.4 | 20,600 | 217188647 |
| 7E[C,U]36AX-**+TDR · cold climate | A80UH2E045A12* | 17.8 | 12.0 | 9.4 | 20,600 | 217188897 |
| 7E[C,U]36BX-**+TDR · cold climate | A97US2V040B12X* | 17.8 | 12.0 | 9.0 | 20,600 | 216769635 |
| 7E[C,U]36BX-**+TDR · cold climate | A97US2V040B12X* | 17.8 | 12.0 | 9.0 | 20,600 | 216769636 |
| 7E[C,U]36BX-**+TDR · cold climate | A80US2V090B12* | 17.8 | 12.0 | 9.0 | 20,600 | 217450111 |
| 7E[C,U]36BX-**+TDR · cold climate | A80US2V090B12* | 17.8 | 12.0 | 9.0 | 20,600 | 217450293 |
| 7EH24BX-**+TDR · cold climate | A97US2V040B12X* | 17.7 | 12.0 | 9.0 | 20,800 | 216769644 |
| 7EH30BX-**+TDR · cold climate | A97US2V040B12X* | 17.7 | 12.0 | 9.0 | 20,800 | 216769651 |
| 7EH30BX-**+TDR · cold climate | A97US2V040B12X* | 17.7 | 12.0 | 9.0 | 20,800 | 216769652 |
| 7EH24BX-**+TDR · cold climate | A97US2V040B12X* | 17.7 | 12.0 | 9.0 | 20,800 | 216769643 |
| 7EH30BX-**+TDR · cold climate | A80US2V090B12* | 17.7 | 12.0 | 9.0 | 20,800 | 217450130 |
| 7EH24BX-**+TDR · cold climate | A80US2V090B12* | 17.7 | 12.0 | 9.0 | 20,800 | 217450121 |
| 7EH30BX-**+TDR · cold climate | A80US2V090B12* | 17.7 | 12.0 | 9.0 | 20,800 | 217450312 |
| 7EH24BX-**+TDR · cold climate | A80US2V090B12* | 17.7 | 12.0 | 9.0 | 20,800 | 217450303 |
| 7EH30AX-**+TDR · cold climate | A80UH1E040A12X* | 17.6 | 11.7 | 9.5 | 20,800 | 217188676 |
| 7EH30AX-**+TDR · cold climate | A80UH1E060A12X* | 17.6 | 11.7 | 9.5 | 21,000 | 217188677 |
| 7EH30AX-**+TDR · cold climate | A80UH1E040A12X* | 17.6 | 11.7 | 9.5 | 20,800 | 217188926 |
| 7EH30AX-**+TDR · cold climate | A80UH1E060A12X* | 17.6 | 11.7 | 9.5 | 21,000 | 217188927 |
| 7AH1AE24PX- · cold climate | - | 17.5 | 12.0 | 9.5 | 23,000 | 216619015 |
| 7AH1AE24PX- · cold climate | - | 17.5 | 12.0 | 9.5 | 23,000 | 216618959 |
| 7AH1AV18PX- · cold climate | - | 17.5 | 11.7 | 9.4 | 23,400 | 216619013 |
| 7AH1AE30PX- · cold climate | - | 17.5 | 12.0 | 9.4 | 23,200 | 216619016 |
| 7AH1AV30PX- · cold climate | - | 17.5 | 12.0 | 9.4 | 23,200 | 216619017 |
| 7AH1AV18PX- · cold climate | - | 17.5 | 11.7 | 9.4 | 23,400 | 216618957 |
| 7AH1AE30PX- · cold climate | - | 17.5 | 12.0 | 9.4 | 23,200 | 216618960 |
| 7AH1AV30PX- · cold climate | - | 17.5 | 12.0 | 9.4 | 23,200 | 216618961 |
| 7E[C,U]36BX-**+TDR · cold climate | A98USMV070B12S* | 17.5 | 12.0 | 9.0 | 20,600 | 217188651 |
| 7E[C,U]36BX-**+TDR · cold climate | A98USMV070B12S* | 17.5 | 12.0 | 9.0 | 20,600 | 217188901 |
| 7E[C,U]36BX-**+TDR · cold climate | A97US2V070B12S* | 17.5 | 12.0 | 9.0 | 20,600 | 216769641 |
| 7E[C,U]36BX-**+TDR · cold climate | A97US2V070B12S* | 17.5 | 12.0 | 9.0 | 20,600 | 216769642 |
| 7E[C,U]30BX-**+TDR · cold climate | A97US2V040B12X* | 17.5 | 11.7 | 9.0 | 20,800 | 216769627 |
| 7E[C,U]30BX-**+TDR · cold climate | A97US2V040B12X* | 17.5 | 11.7 | 9.0 | 20,800 | 216769628 |
| 7EH24BX-**+TDR · cold climate | A97US2V070B12S* | 17.5 | 12.0 | 9.0 | 20,800 | 216769650 |
| 7EH24BX-**+TDR · cold climate | A97US2V070B12S* | 17.5 | 12.0 | 9.0 | 20,800 | 216769649 |
| 7E[C,U]30AX-**+TDR · cold climate | A80UH2E045A12* | 17.5 | 12.0 | 9.0 | 20,600 | 217188635 |
| 7EH24BX-**+TDR · cold climate | A98USMV070B12S* | 17.5 | 12.0 | 9.0 | 20,800 | 217188671 |
| 7E[C,U]36AX-**+TDR · cold climate | A80UH1E040A12X* | 17.5 | 11.7 | 9.0 | 20,800 | 217188644 |
| 7E[C,U]36AX-**+TDR · cold climate | A80UH1E060A12X* | 17.5 | 11.7 | 9.0 | 20,800 | 217188645 |
| 7E[C,U]30AX-**+TDR · cold climate | A80UH2E045A12* | 17.5 | 12.0 | 9.0 | 20,600 | 217188885 |
| 7EH24BX-**+TDR · cold climate | A98USMV070B12S* | 17.5 | 12.0 | 9.0 | 20,800 | 217188921 |
| 7E[C,U]36AX-**+TDR · cold climate | A80UH1E040A12X* | 17.5 | 11.7 | 9.0 | 20,800 | 217188894 |
| 7E[C,U]36AX-**+TDR · cold climate | A80UH1E060A12X* | 17.5 | 11.7 | 9.0 | 20,800 | 217188895 |
| 7EH30AX-**+TDR · cold climate | A80UH1E045A12* | 17.4 | 11.7 | 9.5 | 20,800 | 217188681 |
| 7EH30AX-**+TDR · cold climate | A80UH1E045A12* | 17.4 | 11.7 | 9.5 | 20,800 | 217188931 |
| 7EH30BX-**+TDR · cold climate | A97US2V070B12S* | 17.4 | 12.0 | 9.0 | 20,800 | 216769657 |
| 7EH30BX-**+TDR · cold climate | A97US2V070B12S* | 17.4 | 12.0 | 9.0 | 20,800 | 216769658 |
Yearly running cost in 10 large cities
- Phoenix, AZ$738/yr
- Miami, FL$608/yr
- Houston, TX$661/yr
- Atlanta, GA$652/yr
- Los Angeles, CA$631/yr
- New York, NY$1,538/yr
- Chicago, IL$1,245/yr
- Denver, CO$1,032/yr
- Seattle, WA$631/yr
- Minneapolis, MN$1,275/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Armstrong Air A7SCP18V24P-**A?
- The Armstrong Air A7SCP18V24P-**A is rated at up to 18.5 SEER2 and 12.3 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 268 certified matchups SEER2 ranges from 15.2-18.5.
- Is the Armstrong Air A7SCP18V24P-**A good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 23,400 BTU/h at 5°F with a COP of 1.85, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the Armstrong Air A7SCP18V24P-**A cost to run per year?
- At its rated efficiency it costs about $608-$1,538 a year in electricity in large U.S. cities, depending on climate and local rates - for example $738 in Phoenix and $1,275 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Armstrong Air A7SCP18V24P-**A?
- ENERGY STAR lists 268 certified combinations for this outdoor unit. The highest-rated ones use 7AH2AE30PX-, 7AH1AV24PX-, 7AH2AV30PXC-.
- What refrigerant does the Armstrong Air A7SCP18V24P-**A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Trane/American Standard 5HCL6024A1000A · cold climate18.6 SEER2 · 8.6 HSPF2
- Concord 7SCP18V24P-**A · cold climate18.5 SEER2 · 10.0 HSPF2
- NOVAIR LEA24CEN36-O · cold climate18.6 SEER2 · 10.0 HSPF2
- GE Appliances NS18H24HA5 · cold climate18.5 SEER2 · 10.0 HSPF2
- MRCOOL UHP18024-O · cold climate18.6 SEER2 · 10.0 HSPF2
- Haier 1U24T3PS*HE · cold climate18.5 SEER2 · 10.0 HSPF2
- KEEN Home KEENHYDHP24AA · cold climate18.6 SEER2 · 10.0 HSPF2
- Lennox EL18KSLV-024-230A · cold climate18.5 SEER2 · 10.0 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.