9,000 BTU mini-split heat pump · A-VHP Series
Comfort-Aire A-VHP09SA-1
Excellent cooling and heating efficiency for a 9,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #65 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $184 a year to run in a mixed climate like Atlanta.
- SEER2
- 27.4 Cooling efficiency over a seasonExcellent · beats 96%
- HSPF2
- 13.8 Heating efficiency over a seasonExcellent · beats 97%
- EER2
- 15.4 Cooling efficiency on a 95°F dayExcellent · beats 93%
- Heat at 5°F
- 11,900 BTU/h96% of its 47°F outputBelow average · beats 20%
A good fit if…
- You want low cooling bills - its SEER2 beats 96% of mini-splits.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 11,900 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 97% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Comfort-Aire |
| Also sold as | Century |
| Outdoor unit model | A-VHP09SA-1 |
| Series | A-VHP Series |
| Type | Mini-split heat pump |
| Nominal size | 9,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 11, 2024 |
| Last certified | May 28, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 27.4 (range 20.5-27.4) |
| EER2Efficiency at 95°F outdoors | 14.0-15.4 |
| Cooling capacity | 9,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.9-13.8 |
| Capacity at 47°F | 9,000-12,000 BTU/h |
| Capacity at 17°F | 9,000-12,000 BTU/h |
| Capacity at 5°F | 10,600-11,900 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-1.85 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with B-VHP09SA-1 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| B-VHP09SA-1 COMFORT-AIRE · cold climate | 27.4 | 15.4 | 12.5 | 11,500 | 216097105 |
| B-VHP09SA-1 Comfort Aire · cold climate | 27.4 | 15.4 | 12.5 | 11,500 | 217101902 |
| B-VHP09SA-1 CENTURY · cold climate | 27.4 | 15.4 | 12.5 | 11,500 | 218425154 |
| B-VHP09WA-1 Comfort Aire · cold climate | 27.2 | 15.1 | 10.9 | 11,300 | 217482440 |
| B-VHP09WA-1 CENTURY · cold climate | 27.2 | 15.1 | 10.9 | 11,300 | 217482457 |
| B-VHP09WA-1 COMFORT-AIRE · cold climate | 27.2 | 15.1 | 10.9 | 11,300 | 217618222 |
| B-VHP091A-1 Comfort Aire · cold climate | 24.0 | 14.6 | 12.1 | 10,600 | 217482438 |
| B-VHP091A-1 CENTURY · cold climate | 24.0 | 14.6 | 12.1 | 10,600 | 217482455 |
| B-VHP091A-1 COMFORT-AIRE · cold climate | 24.0 | 14.6 | 12.1 | 10,600 | 217618220 |
| B-VHP09CA-1 Comfort Aire · cold climate | 22.6 | 14.0 | 12.1 | 11,000 | 217482439 |
| B-VHP09CA-1 CENTURY · cold climate | 22.6 | 14.0 | 12.1 | 11,000 | 217482456 |
| B-VHP09CA-1 COMFORT-AIRE · cold climate | 22.6 | 14.0 | 12.1 | 11,000 | 217618221 |
| B-VHP09DA-1 Comfort Aire · cold climate | 20.5 | 14.0 | 13.8 | 11,900 | 217482441 |
| B-VHP09DA-1 CENTURY · cold climate | 20.5 | 14.0 | 13.8 | 11,900 | 217482458 |
| B-VHP09DA-1 COMFORT-AIRE · cold climate | 20.5 | 14.0 | 13.8 | 11,900 | 217618223 |
Yearly running cost in 10 large cities
- Phoenix, AZ$196/yr
- Miami, FL$155/yr
- Houston, TX$176/yr
- Atlanta, GA$184/yr
- Los Angeles, CA$181/yr
- New York, NY$449/yr
- Chicago, IL$366/yr
- Denver, CO$306/yr
- Seattle, WA$189/yr
- Minneapolis, MN$379/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Comfort-Aire A-VHP09SA-1?
- The Comfort-Aire A-VHP09SA-1 is rated at up to 27.4 SEER2 and 15.4 EER2 for cooling and up to 13.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 15 certified matchups SEER2 ranges from 20.5-27.4.
- Is the Comfort-Aire A-VHP09SA-1 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 11,900 BTU/h at 5°F with a COP of 1.85, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the Comfort-Aire A-VHP09SA-1 cost to run per year?
- At its rated efficiency it costs about $155-$449 a year in electricity in large U.S. cities, depending on climate and local rates - for example $196 in Phoenix and $379 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Comfort-Aire A-VHP09SA-1?
- ENERGY STAR lists 15 certified combinations for this outdoor unit. The highest-rated ones use COMFORT-AIRE B-VHP09SA-1, Comfort Aire B-VHP09SA-1, CENTURY B-VHP09SA-1.
- What refrigerant does the Comfort-Aire A-VHP09SA-1 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 9,000 BTU models
- Capella CPPB-H09A-O · cold climate27.4 SEER2 · 13.8 HSPF2
- Custom Comfort CCOXHBSZ09HP · cold climate27.4 SEER2 · 13.8 HSPF2
- CanAir 4C28SCH09H21 · cold climate27.4 SEER2 · 13.8 HSPF2
- DIRECT AIR DIRM4-09HXPRO28-1Z · cold climate27.4 SEER2 · 13.8 HSPF2
- ACIQ ACIQ-09ZPL-HP230C · cold climate27.4 SEER2 · 13.8 HSPF2
- ECO-AIR EDSO-09H · cold climate27.4 SEER2 · 13.8 HSPF2
- AIR-CON ABZCI4H4S09 · cold climate27.5 SEER2 · 10.5 HSPF2
- Innovair MOS09H2BH0A · cold climate27.4 SEER2 · 13.8 HSPF2
See all 395 9,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 28, 2026. How we use the data.