18,000 BTU mini-split heat pump · A-series
Comfort-Aire A-VMH18DV-1
Average cooling efficiency and below average heating efficiency for a 18,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #228 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $508 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.0 Cooling efficiency over a seasonAverage · beats 48%
- HSPF2
- 9.8 Heating efficiency over a seasonBelow average · beats 33%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- 19,700 BTU/h99% of its 47°F outputBelow average · beats 27%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 19,700 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You mainly need heat - its HSPF2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Comfort-Aire |
| Also sold as | Century |
| Outdoor unit model | A-VMH18DV-1 |
| Series | A-series |
| Type | Mini-split heat pump |
| Nominal size | 18,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | December 18, 2019 |
| Last certified | June 13, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.0 (range 19.0-22.0) |
| EER2Efficiency at 95°F outdoors | 12.0-12.5 |
| Cooling capacity | 19,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.3-9.8 |
| Capacity at 47°F | 20,000 BTU/h |
| Capacity at 17°F | 15,000-16,000 BTU/h |
| Capacity at 5°F | 19,000-19,700 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.85-1.90 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - COMFORT-AIRE · cold climate | 22.0 | 12.5 | 9.8 | 19,700 | 207657610 |
| - CENTURY · cold climate | 22.0 | 12.5 | 9.8 | 19,700 | 212940821 |
| - Comfort Aire · cold climate | 22.0 | 12.5 | 9.8 | 19,700 | 217101841 |
| - COMFORT-AIRE · cold climate | 20.5 | 12.3 | 9.6 | 19,300 | 207657611 |
| - CENTURY · cold climate | 20.5 | 12.3 | 9.6 | 19,300 | 212940822 |
| - Comfort Aire · cold climate | 20.5 | 12.3 | 9.6 | 19,300 | 217101842 |
| - COMFORT-AIRE · cold climate | 19.0 | 12.0 | 9.3 | 19,000 | 207657609 |
| - CENTURY · cold climate | 19.0 | 12.0 | 9.3 | 19,000 | 212940820 |
| - Comfort Aire · cold climate | 19.0 | 12.0 | 9.3 | 19,000 | 217101840 |
Yearly running cost in 10 large cities
- Phoenix, AZ$525/yr
- Miami, FL$408/yr
- Houston, TX$472/yr
- Atlanta, GA$508/yr
- Los Angeles, CA$501/yr
- New York, NY$1,250/yr
- Chicago, IL$1,022/yr
- Denver, CO$855/yr
- Seattle, WA$530/yr
- Minneapolis, MN$1,061/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Comfort-Aire A-VMH18DV-1?
- The Comfort-Aire A-VMH18DV-1 is rated at up to 22.0 SEER2 and 12.5 EER2 for cooling and up to 9.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 9 certified matchups SEER2 ranges from 19.0-22.0.
- Is the Comfort-Aire A-VMH18DV-1 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 19,700 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the Comfort-Aire A-VMH18DV-1 cost to run per year?
- At its rated efficiency it costs about $408-$1,250 a year in electricity in large U.S. cities, depending on climate and local rates - for example $525 in Phoenix and $1,061 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- What refrigerant does the Comfort-Aire A-VMH18DV-1 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 18,000 BTU models
- C&H CH-HPR19M-230VO · cold climate22.0 SEER2 · 9.8 HSPF2
- EMI MHMZ218DA · cold climate22.0 SEER2 · 9.8 HSPF2
- Bosch BMS500-AAM018-1CSXHC · cold climate22.0 SEER2 · 9.8 HSPF2
- MDV M2OI-18HFN1-M · cold climate22.0 SEER2 · 9.8 HSPF2
- 1HVAC ACIQ-18Z-HH-M2B · cold climate22.0 SEER2 · 9.8 HSPF2
- MOOVAIR DMA18HOM25230X3 · cold climate22.0 SEER2 · 9.8 HSPF2
- Ruud FPHMR18A3D · cold climate22.0 SEER2 · 10.0 HSPF2
- NOVAIR LEA20MZ-2P-35SK-O · cold climate22.0 SEER2 · 9.8 HSPF2
See all 465 18,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 13, 2026. How we use the data.