HVAC Rated

36,000 BTU mini-split heat pump · C series

ComfortStar CHF36CD(O)

Below average cooling efficiency and very good heating efficiency for a 36,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #177 of 205 36,000 BTU mini-splits for cooling efficiency, and costs about $996 a year to run in a mixed climate like Atlanta.

SEER2
19.4 Cooling efficiency over a season
Below average · beats 11%
HSPF2
11.0 Heating efficiency over a season
Very good · beats 75%
EER2
9.5 Cooling efficiency on a 95°F day
Below average · beats 3%
Heat at 5°F
40,000 BTU/h100% of its 47°F output
Below average · beats 37%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 40,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 75% of mini-splits.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications36,000 BTU, R-410A
General
BrandComfortStar
Outdoor unit modelCHF36CD(O)
SeriesC series
TypeMini-split heat pump
Nominal size36,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceFebruary 2, 2020
Last certifiedMay 28, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.4 (range 16.5-19.4)
EER2Efficiency at 95°F outdoors8.8-9.5
Cooling capacity36,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.0-11.0
Capacity at 47°F39,000-42,000 BTU/h
Capacity at 17°F32,000-34,000 BTU/h
Capacity at 5°F36,000-40,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-1.98
ENERGY STAR cold climateYes
Heating output as it gets colder100% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TIP-36 at the standard test temperatures, in BTU/h:

Certified matchups4 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
TIP-36 COMFORTSTAR · cold climate19.49.510.540,000207658953
FPA-36DU COMFORTSTAR · cold climate17.68.810.036,600207658962
CPA-36C COMFORTSTAR · cold climate16.59.011.036,000207658941
CPA-36DUB COMFORTSTAR · cold climate16.59.011.036,000207765965
Yearly running cost in 10 large cities$873-$2,396

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the ComfortStar CHF36CD(O)?
The ComfortStar CHF36CD(O) is rated at up to 19.4 SEER2 and 9.5 EER2 for cooling and up to 11.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 16.5-19.4.
Is the ComfortStar CHF36CD(O) good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 40,000 BTU/h at 5°F with a COP of 1.98, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the ComfortStar CHF36CD(O) cost to run per year?
At its rated efficiency it costs about $873-$2,396 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,085 in Phoenix and $2,009 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the ComfortStar CHF36CD(O)?
ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use COMFORTSTAR TIP-36, COMFORTSTAR FPA-36DU, COMFORTSTAR CPA-36C.
What refrigerant does the ComfortStar CHF36CD(O) use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,081/yrYou save $874/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump ComfortStar CHF36CD(O)
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,081
Current system, per year
$1,954
You save per year
$874
Payback
15.5 years
Net after 10 years
-$4,764

Cooling $653Heating $428Electricity used: 6,755 kWhSaved vs. a minimum-efficiency heat pump: $433

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 36,000 BTU models

See all 205 36,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 28, 2026. How we use the data.