HVAC Rated

24,000 BTU mini-split heat pump · AURORA Multi

Daikin 3MXTH24AVJU

Below average cooling and heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #383 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $666 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Below average · beats 9%
HSPF2
9.5 Heating efficiency over a season
Below average · beats 24%
EER2
12.5 Cooling efficiency on a 95°F day
Average · beats 44%
Heat at 5°F
24,000 BTU/h100% of its 47°F output
Below average · beats 9%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 24,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You mainly need heat - its HSPF2 is below average for mini-splits.

Calculate my running cost

Details

Specifications24,000 BTU, R-32
General
BrandDaikin
Outdoor unit model3MXTH24AVJU
SeriesAURORA Multi
TypeMini-split heat pump
Nominal size24,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceOctober 20, 2025
Last certifiedJanuary 14, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 16.0-19.0)
EER2Efficiency at 95°F outdoors11.0-12.5
Cooling capacity24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.3-9.5
Capacity at 47°F24,000 BTU/h
Capacity at 17°F14,000 BTU/h
Capacity at 5°F24,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80
ENERGY STAR cold climateYes
Heating output as it gets colder100% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:

Certified matchups3 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
- DAIKIN · cold climate19.012.59.524,000217747239
- DAIKIN · cold climate17.511.88.924,000218043338
- DAIKIN · cold climate16.011.08.324,000218043337
Yearly running cost in 10 large cities$594-$1,594

At each state's average electricity price and the city's typical heating and cooling hours.

Questions4
What is the SEER2 rating of the Daikin 3MXTH24AVJU?
The Daikin 3MXTH24AVJU is rated at up to 19.0 SEER2 and 12.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 16.0-19.0.
Is the Daikin 3MXTH24AVJU good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 24,000 BTU/h at 5°F with a COP of 1.80, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the Daikin 3MXTH24AVJU cost to run per year?
At its rated efficiency it costs about $594-$1,594 a year in electricity in large U.S. cities, depending on climate and local rates - for example $733 in Phoenix and $1,333 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
What refrigerant does the Daikin 3MXTH24AVJU use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $728/yrYou save $510/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Daikin 3MXTH24AVJU
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$728
Current system, per year
$1,238
You save per year
$510
Payback
17.6 years
Net after 10 years
-$3,901

Cooling $445Heating $283Electricity used: 4,547 kWhSaved vs. a minimum-efficiency heat pump: $222

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 24,000 BTU models

See all 430 24,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 14, 2026. How we use the data.