HVAC Rated

4-ton central heat pump · 2-STAGE 18 SEER HP

Day & Night N5H8T48*K*AAA

Average cooling efficiency and below average heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #103 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,503 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
26,600 BTU/h50% of its 47°F output
Excellent · beats 90%

A good fit if…

  • You want a choice of indoor units - 3,888 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandDay & Night
Also sold asHeil, Airquest, Arcoaire, Comfortmaker, Keeprite, Tempstar, Kenmore, ACIQ, MARATHERM
Outdoor unit modelN5H8T48*K*AAA
Series2-STAGE 18 SEER HP
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 4, 2024
Last certifiedOctober 7, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 15.2-18.0)
EER2Efficiency at 95°F outdoors11.7-13.5
Cooling capacity45,500-50,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F48,500-52,500 BTU/h
Capacity at 17°F30,000-32,600 BTU/h
Capacity at 5°F23,800-26,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.06-2.32
ENERGY STAR cold climateNo
Heating output as it gets colder50% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with QFVA5D6021X at the standard test temperatures, in BTU/h:

Certified matchups3,888 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 3,888 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
QFVA5D6021X-18.013.08.525,800218695453
QFVA5D6021X-18.013.08.525,800218695452
QFVA5D6021X-18.013.08.525,800218695451
QFVA5D6021X-18.013.08.525,800218695450
QFVA5D6021X-18.013.08.525,800218695449
QFVA5D6021X-18.013.08.525,800218695448
QFVA5D6021X-18.013.08.525,800218695447
QFVA5D6021X-18.013.08.525,800218695446
QFVA5D6021X-18.013.08.525,800218822090
FTMA5B60L0D-18.013.58.124,600215560720
FTMA5B60L0D-18.013.58.124,600215560721
FTMA5B60L0D-18.013.58.124,600215560719
FTMA5B60L0D-18.013.58.124,600215560722
FTMA5B60L0D-18.013.58.124,600215560725
FTMA5B60L0D-18.013.58.124,600215560726
FTMA5B60L0D-18.013.58.124,600215560723
FTMA5B60L0D-18.013.58.124,600215560724
FTMA5B60L0D-18.013.58.124,600215560727
FTMA5B60L0D-18.013.58.124,600215561906
EVD5X61M21A*80VSL1102122B*17.512.58.524,800215625030
EVD5X61M21A*80VSL1102122B*17.512.58.524,800215625028
EVD5X61M21A*80VSL1102122B*17.512.58.524,800215625029
EVD5X61M21A*80VSL1102122B*17.512.58.524,800215625032
EVD5X61M21A*80VSL1102122B*17.512.58.524,800215625033
EVD5X61M21A*80VSL1102122B*17.512.58.524,800215625031
EVD5X61M21A*80VSL1102122B*17.512.58.524,800215625034
EVD5X61M21A*80VSL1102122B*17.512.58.524,800215625035
EVD5X61M21A*80MSU0802120A*17.513.08.524,400215625063
EVD5X61M21A*80MSU0802120A*17.513.08.524,400215625064
EVD5X61M21A*80MSU0802120A*17.513.08.524,400215625065
EVD5X61M21A*80MSU0802120A*17.513.08.524,400215625067
EVD5X61M21A*80MSU0802120A*17.513.08.524,400215625066
EVD5X61M21A*80MSU0802120A*17.513.08.524,400215625071
EVD5X61M21A*80MSU0802120A*17.513.08.524,400215625069
EVD5X61M21A*80MSU0802120A*17.513.08.524,400215625068
EVD5X61M21A*80MSU0802120A*17.513.08.524,400215625070
EVD5X61M21A*80MSU1002120A*17.512.58.525,000215625082
EVD5X61M21A*80MSU1002120A*17.512.58.525,000215625083
EVD5X61M21A*80MSU1002120A*17.512.58.525,000215625085
EVD5X61M21A*80MSU1002120A*17.512.58.525,000215625086
EVD5X61M21A*80MSU1002120A*17.512.58.525,000215625087
EVD5X61M21A*80MSU1002120A*17.512.58.525,000215625084
EVD5X61M21A*80MSU1002120A*17.512.58.525,000215625088
EVD5X61M21A*80MSU1002120A*17.512.58.525,000215625089
EVD5X61M21A*80MSU1002120A*17.512.58.525,000215625090
EVD5X61M21A*80CTL0902120B*17.512.08.525,200215625114
EVD5X61M21A*80CTL0902120B*17.512.08.525,200215625113
EVD5X61M21A*80CTL0902120B*17.512.08.525,200215625112
EVD5X61M21A*80CTL0902120B*17.512.08.525,200215625117
EVD5X61M21A*80CTL0902120B*17.512.08.525,200215625116
EVD5X61M21A*80CTL0902120B*17.512.08.525,200215625115
EVD5X61M21A*80CTL0902120B*17.512.08.525,200215625119
EVD5X61M21A*80CTL0902120B*17.512.08.525,200215625120
EVD5X61M21A*80CTL0902120B*17.512.08.525,200215625118
EVD5X61M21A*80CTL1102120B*17.512.58.525,000215625126
EVD5X61M21A*80CTL1102120B*17.512.58.525,000215625128
EVD5X61M21A*80CTL1102120B*17.512.58.525,000215625127
EVD5X61M21A*80CTL1102120B*17.512.58.525,000215625129
EVD5X61M21A*80CTL1102120B*17.512.58.525,000215625131
EVD5X61M21A*80CTL1102120B*17.512.58.525,000215625130
Yearly running cost in 10 large cities$1,270-$3,652

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Day & Night N5H8T48*K*AAA?
The Day & Night N5H8T48*K*AAA is rated at up to 18.0 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3888 certified matchups SEER2 ranges from 15.2-18.0.
Is the Day & Night N5H8T48*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the Day & Night N5H8T48*K*AAA cost to run per year?
At its rated efficiency it costs about $1,270-$3,652 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,601 in Phoenix and $3,079 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Day & Night N5H8T48*K*AAA?
ENERGY STAR lists 3888 certified combinations for this outdoor unit. The highest-rated ones use QFVA5D6021X, FTMA5B60L0D, EVD5X61M21A.
What refrigerant does the Day & Night N5H8T48*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,607/yrYou save $918/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Day & Night N5H8T48*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,607
Current system, per year
$2,525
You save per year
$918
Payback
19.6 years
Net after 10 years
-$8,819

Cooling $948Heating $659Electricity used: 10,045 kWhSaved vs. a minimum-efficiency heat pump: $333

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 7, 2026. How we use the data.