HVAC Rated

3.5-ton central heat pump · F Series

Friedrich FWP14AY42AJ2N

Below average cooling and heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.

Ranks #129 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,366 a year to run in a mixed climate like Atlanta.

SEER2
15.2 Cooling efficiency over a season
Below average · beats 6%
HSPF2
7.8 Heating efficiency over a season
Below average · beats 5%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
- Not reported by the maker

A good fit if…

  • You want a certified 3.5-ton central heat pump at a typical efficiency level.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandFriedrich
Outdoor unit modelFWP14AY42AJ2N
SeriesF Series
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceApril 1, 2024
Last certifiedDecember 11, 2024
Cooling
SEER2Seasonal efficiency, higher is better15.2 (range 15.2)
EER2Efficiency at 95°F outdoors11.7
Cooling capacity40,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8
Capacity at 47°F40,000 BTU/h
Capacity at 17°F25,600 BTU/h
Capacity at 5°F-
COP at 5°F2.0 = twice as efficient as a space heater-
ENERGY STAR cold climateNo
Heating output as it gets colder

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TCFY4824STANM at the standard test temperatures, in BTU/h:

Certified matchups8 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
TCFY4824STANMFR802V1255A24DZ15.211.77.8-214592322
TCFY4824STANMFR951V1155A24M415.211.77.8-214592453
TCFY4824STANMFR921V1155A24M415.211.77.8-214592438
TCFY4824STANMFR801V1255A24DZ15.211.77.8-214592129
RCFY4824STANMFR801V1255A24DZ15.211.77.8-216541285
RCFY4824STANMFR921V1155A24M415.211.77.8-216541318
RCFY4824STANMFR951V1155A24M415.211.77.8-216541323
RCFY4824STANMFR802V1255A24DZ15.211.77.8-216543095
Yearly running cost in 10 large cities$1,236-$3,252

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Friedrich FWP14AY42AJ2N?
The Friedrich FWP14AY42AJ2N is rated at up to 15.2 SEER2 and 11.7 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Friedrich FWP14AY42AJ2N good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
How much does the Friedrich FWP14AY42AJ2N cost to run per year?
At its rated efficiency it costs about $1,236-$3,252 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,516 in Phoenix and $2,712 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Friedrich FWP14AY42AJ2N?
ENERGY STAR lists 8 certified combinations for this outdoor unit. The highest-rated ones use TCFY4824STANM, RCFY4824STANM.
What refrigerant does the Friedrich FWP14AY42AJ2N use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,501/yrYou save $562/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Friedrich FWP14AY42AJ2N
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,501
Current system, per year
$2,063
You save per year
$562
Payback
26.7 years
Net after 10 years
-$9,382

Cooling $926Heating $574Electricity used: 9,379 kWhSaved vs. a minimum-efficiency heat pump: $81

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of December 11, 2024. How we use the data.