HVAC Rated

3-ton central heat pump · VERSUS

Friedrich FWP15AY36AJ2N

Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #256 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,146 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
7.8 Heating efficiency over a season
Below average · beats 5%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
18,900 BTU/h54% of its 47°F output
Below average · beats 39%

A good fit if…

  • You want a choice of indoor units - 134 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandFriedrich
Outdoor unit modelFWP15AY36AJ2N
SeriesVERSUS
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceAugust 13, 2024
Last certifiedJanuary 31, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7
Cooling capacity34,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8
Capacity at 47°F33,200-34,200 BTU/h
Capacity at 17°F23,400-33,200 BTU/h
Capacity at 5°F17,300-18,900 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00
ENERGY STAR cold climateNo
Heating output as it gets colder54% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TCFY3621STANM at the standard test temperatures, in BTU/h:

Certified matchups134 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 134 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
TCFY3621STANMFR801V0755A21DZ16.011.77.818,300216545798
TCFY3621STANMFR801V0755A21UH16.011.77.818,400216545803
TCFY3621STANMFR801V1005A21DZ16.011.77.818,200216545808
TCFY3621STANMFR801V1004A17UH16.011.77.818,400216545801
TCFY3621STANMFR801V1005A21UHN16.011.77.818,300216545810
TCFY3621STANMFR801V1005A21UHS16.011.77.818,300216545822
RCFY3621STANMFR801V1005A21UHS16.011.77.818,300216545995
TCFY3621STANMFR951V0705A21UHU16.011.77.818,500216545902
TCFY3621STANMFR801V1005A21UHU16.011.77.818,400216545969
RCFY3621STANMFR801V1004A17UH16.011.77.818,400216545973
RCFY3621STANMFR801V0755A21UH16.011.77.818,400216545976
RCFY3621STANMFR801V0755A21DZ16.011.77.818,300216545971
RCFY3621STANMFR801V1005A21UHN16.011.77.818,300216545983
RCFY3621STANMFR801V1005A21DZ16.011.77.818,200216545981
TCFY3621STANMFR802V1004A17UH16.011.77.818,400216546530
TCFY3621STANMFR802V0755A21DZ16.011.77.818,300216546533
TCFY3621STANMFR802V0755A21UH16.011.77.818,400216546538
TCFY3621STANMFR802V1005A21DZ16.011.77.818,200216546562
TCFY3621STANMFR802V1005A21UH16.011.77.818,300216546564
RCFY3617STANMFR801V1004A17UH16.011.77.818,400216543298
RCFY3621STANMFR802V1004A17UH16.011.77.818,400216546569
RCFY3621STANMFR802V0755A21DZ16.011.77.818,300216546571
RCFY3621STANMFR802V0755A21UH16.011.77.818,400216546576
RCFY3621STANMFR802V1005A21DZ16.011.77.818,200216546599
RCFY3621STANMFR802V1005A21UH16.011.77.818,300216546602
RCFY3621STANMFR951V0705A21UHU16.011.77.818,500216546071
RCFY3621STANMFR801V1005A21UHU16.011.77.818,400216546137
RCFY3617STANMFR802V1004A17UH16.011.77.818,400216544897
FRH2TY3617STANN-15.211.77.817,300215415473
TCFY3617STANMFR801V0503A14DZ15.211.77.818,400215656626
TCFY3617STANMFR801V0754A17UH15.211.77.818,300215656639
TCFY3617STANMFR801V0754A17DZ15.211.77.818,600215656645
TCFY3617STANMFR801V0503A14UH15.211.77.818,600215656663
TCFY3617STANMFR801V0504A17UHN15.211.77.818,900215656711
TCFY3617STANMFR801V0704A17UH15.211.77.818,700215656719
TCFY3617STANMFR801V0504A17UHS15.211.77.818,900215656722
TCFY3617STANMFR801V1004A17UH15.211.77.818,400215656734
TCFY3617STANMFR802V0503A14DZ15.211.77.818,400215656749
TCFY3617STANMFR802V1004A17UH15.211.77.818,400215656756
TCFY3617STANMFR802V0754A17DZ15.211.77.818,600215656792
TCFY3617STANMFR802V0503A14UH15.211.77.818,600215656796
TCFY3617STANMFR802V0754A17UH15.211.77.818,300215656824
TCFY3617STANMFR951V0703A17M415.211.77.818,400215656861
TCFY3617STANMFR951V0603A17M415.211.77.818,600215656884
TCFY3617STANMFR921V0403A17M415.211.77.818,600215656955
TCFY3617STANMFR951V0403A17M415.211.77.818,600215656935
TCFY3617STANMFR921V0703A17M415.211.77.818,400215656948
TCFY3617STANMFR921V0603A17M415.211.77.818,600215657035
TCFY3617STANMFR962V0603A17M415.211.77.818,600215657053
TCFY3617STANMFR962V0703A17M415.211.77.818,400215657319
TCFY3617STANMFR962V0403A17M415.211.77.818,600215657347
TCFY3617STANMFR802V0504A17UH15.211.77.818,900215657431
TCFY3617STANMFR801V0504A17UHU15.211.77.818,700215657512
RCFY3617STANMFR951V0403A17M415.211.77.818,600216543759
TCFY3621STANMFR962V0603A17M415.211.77.818,600216546285
TCFY3621STANMFR962V1005A21M415.211.77.818,500216546287
TCFY3621STANMFR962V0403A17M415.211.77.818,600216546304
TCFY3621STANMFR962V0703A17M415.211.77.818,400216546306
TCFY3621STANMFR962V0705A21M415.211.77.818,500216546308
TCFY3621STANMFR962V0855A21M415.211.77.818,600216546311
Yearly running cost in 10 large cities$1,005-$2,754

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Friedrich FWP15AY36AJ2N?
The Friedrich FWP15AY36AJ2N is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 134 certified matchups SEER2 ranges from 15.2-16.0.
Is the Friedrich FWP15AY36AJ2N good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Friedrich FWP15AY36AJ2N cost to run per year?
At its rated efficiency it costs about $1,005-$2,754 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,248 in Phoenix and $2,307 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Friedrich FWP15AY36AJ2N?
ENERGY STAR lists 134 certified combinations for this outdoor unit. The highest-rated ones use TCFY3621STANM, RCFY3621STANM, RCFY3617STANM.
What refrigerant does the Friedrich FWP15AY36AJ2N use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,243/yrYou save $520/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Friedrich FWP15AY36AJ2N
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,243
Current system, per year
$1,763
You save per year
$520
Payback
25.0 years
Net after 10 years
-$7,800

Cooling $752Heating $491Electricity used: 7,772 kWhSaved vs. a minimum-efficiency heat pump: $109

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 31, 2025. How we use the data.