HVAC Rated

3-ton central heat pump · QUIETCOMFORT DELUXE 20 VS HP

Heil B5H0V36*K*AAA

Excellent cooling efficiency and very good heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #39 of 302 3 ton central heat pumps for cooling efficiency, and costs about $961 a year to run in a mixed climate like Atlanta.

SEER2
19.5 Cooling efficiency over a season
Excellent · beats 91%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
11.5 Cooling efficiency on a 95°F day
Below average · beats 31%
Heat at 5°F
26,000 BTU/h72% of its 47°F output
Average · beats 48%

A good fit if…

  • You want low cooling bills - its SEER2 beats 91% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 26,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandHeil
Also sold asArcoaire, Airquest, Keeprite, Day & Night, Comfortmaker, Tempstar, Kenmore, ACIQ
Outdoor unit modelB5H0V36*K*AAA
SeriesQUIETCOMFORT DELUXE 20 VS HP
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 12, 2023
Last certifiedSeptember 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.5 (range 16.0-19.5)
EER2Efficiency at 95°F outdoors9.0-11.5
Cooling capacity32,600-35,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-9.5
Capacity at 47°F34,000-36,200 BTU/h
Capacity at 17°F29,400-31,800 BTU/h
Capacity at 5°F23,600-26,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.64-2.04
ENERGY STAR cold climateYes
Heating output as it gets colder72% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FCMA5B60L0D*+WALLCON at the standard test temperatures, in BTU/h:

Certified matchups2,465 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 2,465 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FCMA5B60L0D*+WALLCON · cold climate-19.511.59.524,400218162465
FCMA5B60L0D*+WALLCON · cold climate-19.511.59.524,400218162464
FCMA5B60L0D*+WALLCON · cold climate-19.511.59.524,400218162463
FCMA5B60L0D*+WALLCON · cold climate-19.511.59.524,400218164744
FCMA5B60L0D*+WALLCON · cold climate-19.511.59.524,400218168538
FCMA5B60L0D*+WALLCON · cold climate-19.511.59.524,400218171236
FCMA5B60L0D*+WALLCON · cold climate-19.511.59.524,400218171235
FCMA5B60L0D*+WALLCON · cold climate-19.511.59.524,400218171234
FCMA5B60L0D*+WALLCON · cold climate-19.511.59.524,400218356238
FCMA5B48L0C*+WALLCON · cold climate-19.011.09.024,600218161829
FCMA5B48L0C*+WALLCON · cold climate-19.011.09.024,600218161828
FCMA5B48L0C*+WALLCON · cold climate-19.011.09.024,600218161827
FCMA5B48L0C*+WALLCON · cold climate-19.011.09.024,600218168326
FCMA5B48L0C*+WALLCON · cold climate-19.011.09.024,600218164532
FCMA5B48L0C*+WALLCON · cold climate-19.011.09.024,600218170598
FCMA5B48L0C*+WALLCON · cold climate-19.011.09.024,600218170597
FCMA5B48L0C*+WALLCON · cold climate-19.011.09.024,600218170596
FCMA5B48L0C*+WALLCON · cold climate-19.011.09.024,600218356042
EVD5X61M24A*+WALLCON*80CTL1352422B*19.011.08.523,600218172169
EVD5X61M24A*+WALLCON*80CTL1352422B*19.011.08.523,600218172168
EVD5X61M24A*+WALLCON*80CTL1352422B*19.011.08.523,600218172167
EVD5X61M24A*+WALLCON*80CTL1102120B*19.011.08.523,600218172166
EVD5X61M24A*+WALLCON*80CTL1102120B*19.011.08.523,600218172165
EVD5X61M24A*+WALLCON*80CTL1102120B*19.011.08.523,600218172164
EVD5X61M24A*+WALLCON*80CTL0902120B*19.011.08.523,600218172163
EVD5X61M24A*+WALLCON*80CTL0902120B*19.011.08.523,600218172162
EVD5X61M24A*+WALLCON*80CTL0902120B*19.011.08.523,600218172161
EVD5X61M24A*+WALLCON*80CTL1352422B*19.011.08.523,600218165055
EVD5X61M24A*+WALLCON*80CTL1102120B*19.011.08.523,600218165054
EVD5X61M24A*+WALLCON*80CTL0902120B*19.011.08.523,600218165053
EVD5X61M24A*+WALLCON*80CTL1352422B*19.011.08.523,600218163400
EVD5X61M24A*+WALLCON*80CTL1352422B*19.011.08.523,600218163398
EVD5X61M24A*+WALLCON*80CTL1352422B*19.011.08.523,600218163396
EVD5X61M24A*+WALLCON*80CTL1102120B*19.011.08.523,600218163395
EVD5X61M24A*+WALLCON*80CTL1102120B*19.011.08.523,600218163394
EVD5X61M24A*+WALLCON*80CTL1102120B*19.011.08.523,600218163393
EVD5X61M24A*+WALLCON*80CTL0902120B*19.011.08.523,600218163392
EVD5X61M24A*+WALLCON*80CTL0902120B*19.011.08.523,600218163391
EVD5X61M24A*+WALLCON*80CTL0902120B*19.011.08.523,600218163390
EVM5X61M24A*+WALLCON*80CTL1352422B*19.011.08.523,600218171602
EVM5X61M24A*+WALLCON*80CTL1352422B*19.011.08.523,600218171601
EVM5X61M24A*+WALLCON*80CTL1352422B*19.011.08.523,600218171600
EVM5X61M24A*+WALLCON*80CTL1102120B*19.011.08.523,600218171599
EVM5X61M24A*+WALLCON*80CTL1102120B*19.011.08.523,600218171598
EVM5X61M24A*+WALLCON*80CTL1102120B*19.011.08.523,600218171597
EVM5X61M24A*+WALLCON*80CTL1352422B*19.011.08.523,600218164866
EVM5X61M24A*+WALLCON*80CTL1352422B*19.011.08.523,600218162831
EVM5X61M24A*+WALLCON*80CTL1352422B*19.011.08.523,600218162830
EVM5X61M24A*+WALLCON*80CTL1352422B*19.011.08.523,600218162829
EVM5X61M24A*+WALLCON*80CTL1102120B*19.011.08.523,600218162828
EVM5X61M24A*+WALLCON*80CTL1102120B*19.011.08.523,600218162827
EVM5X61M24A*+WALLCON*80CTL1102120B*19.011.08.523,600218162826
EVM5X61M24A*+WALLCON*80CTL0902120B*19.011.08.523,600218171596
EVM5X61M24A*+WALLCON*80CTL0902120B*19.011.08.523,600218171595
EVM5X61M24A*+WALLCON*80CTL0902120B*19.011.08.523,600218171594
EVM5X61M24A*+WALLCON*80CTL1102120B*19.011.08.523,600218164865
EVM5X61M24A*+WALLCON*80CTL0902120B*19.011.08.523,600218164864
EVM5X61M24A*+WALLCON*80CTL0902120B*19.011.08.523,600218162825
EVM5X61M24A*+WALLCON*80CTL0902120B*19.011.08.523,600218162824
EVM5X61M24A*+WALLCON*80CTL0902120B*19.011.08.523,600218162823
Yearly running cost in 10 large cities$826-$2,325

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Heil B5H0V36*K*AAA?
The Heil B5H0V36*K*AAA is rated at up to 19.5 SEER2 and 11.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 2465 certified matchups SEER2 ranges from 16.0-19.5.
Is the Heil B5H0V36*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 26,000 BTU/h at 5°F with a COP of 2.04, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Heil B5H0V36*K*AAA cost to run per year?
At its rated efficiency it costs about $826-$2,325 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,034 in Phoenix and $1,955 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Heil B5H0V36*K*AAA?
ENERGY STAR lists 2465 certified combinations for this outdoor unit. The highest-rated ones use FCMA5B60L0D*+WALLCON, FCMA5B48L0C*+WALLCON, EVD5X61M24A*+WALLCON.
What refrigerant does the Heil B5H0V36*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,035/yrYou save $748/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Heil B5H0V36*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,035
Current system, per year
$1,783
You save per year
$748
Payback
17.4 years
Net after 10 years
-$5,516

Cooling $617Heating $417Electricity used: 6,467 kWhSaved vs. a minimum-efficiency heat pump: $336

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.