HVAC Rated

24,000 BTU mini-split heat pump · Hi UNI

Hisense AUW-24U3TK1

Below average cooling efficiency and average heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #328 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $614 a year to run in a mixed climate like Atlanta.

SEER2
20.0 Cooling efficiency over a season
Below average · beats 18%
HSPF2
10.5 Heating efficiency over a season
Average · beats 61%
EER2
12.0 Cooling efficiency on a 95°F day
Below average · beats 25%
Heat at 5°F
24,000 BTU/h100% of its 47°F output
Average · beats 48%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 24,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.

Calculate my running cost

Details

Specifications24,000 BTU, R-454B
General
BrandHisense
Outdoor unit modelAUW-24U3TK1
SeriesHi UNI
TypeMini-split heat pump
Nominal size24,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 2, 2024
Last certifiedMarch 9, 2026
Cooling
SEER2Seasonal efficiency, higher is better20.0 (range 19.0-20.0)
EER2Efficiency at 95°F outdoors11.0-12.0
Cooling capacity18,000-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.5-10.5
Capacity at 47°F18,000-24,000 BTU/h
Capacity at 17°F18,000-19,100 BTU/h
Capacity at 5°F18,000-24,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-2.00
ENERGY STAR cold climateYes
Heating output as it gets colder100% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ACT-24UR3TJA1 at the standard test temperatures, in BTU/h:

Certified matchups6 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
ACT-24UR3TJA1 HISENSE · cold climate20.012.010.524,000216019253
AST-24UW3TKN**00 HISENSE · cold climate20.011.010.024,000217231620
AST-24UW3TKW**00 HISENSE · cold climate20.011.09.524,000217231612
AUH-24UX3TFH5 HISENSE · cold climate19.011.710.024,000217464060
AUH-18UX3TFH5 HISENSE · cold climate19.011.710.018,000217465404
ADT-24UX3TFM1 HISENSE · cold climate19.011.79.524,000216441750
Yearly running cost in 10 large cities$563-$1,456

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Hisense AUW-24U3TK1?
The Hisense AUW-24U3TK1 is rated at up to 20.0 SEER2 and 12.0 EER2 for cooling and up to 10.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 6 certified matchups SEER2 ranges from 19.0-20.0.
Is the Hisense AUW-24U3TK1 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 24,000 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Hisense AUW-24U3TK1 cost to run per year?
At its rated efficiency it costs about $563-$1,456 a year in electricity in large U.S. cities, depending on climate and local rates - for example $687 in Phoenix and $1,211 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Hisense AUW-24U3TK1?
ENERGY STAR lists 6 certified combinations for this outdoor unit. The highest-rated ones use HISENSE ACT-24UR3TJA1, HISENSE AST-24UW3TKN**00, HISENSE AST-24UW3TKW**00.
What refrigerant does the Hisense AUW-24U3TK1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $678/yrYou save $559/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Hisense AUW-24U3TK1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$678
Current system, per year
$1,238
You save per year
$559
Payback
16.1 years
Net after 10 years
-$3,409

Cooling $422Heating $256Electricity used: 4,240 kWhSaved vs. a minimum-efficiency heat pump: $271

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 24,000 BTU models

See all 430 24,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 9, 2026. How we use the data.