HVAC Rated

3-ton central heat pump · ELITE EL17XP1 Series

Lennox EL17XP1-036-230A

Average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #180 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,060 a year to run in a mixed climate like Atlanta.

SEER2
16.8 Cooling efficiency over a season
Average · beats 45%
HSPF2
8.7 Heating efficiency over a season
Average · beats 47%
EER2
13.5 Cooling efficiency on a 95°F day
Excellent · beats 95%
Heat at 5°F
19,300 BTU/h54% of its 47°F output
Excellent · beats 93%

A good fit if…

  • You want a choice of indoor units - 570 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3 ton, R-410A
General
BrandLennox
Outdoor unit modelEL17XP1-036-230A
SeriesELITE EL17XP1 Series
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 6, 2022
Last certifiedOctober 27, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.8 (range 15.2-16.8)
EER2Efficiency at 95°F outdoors12.2-13.5
Cooling capacity34,800-36,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.7
Capacity at 47°F32,400-36,000 BTU/h
Capacity at 17°F21,400-24,000 BTU/h
Capacity at 5°F16,800-19,300 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.06-2.36
ENERGY STAR cold climateNo
Heating output as it gets colder54% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CHX35-42C-**-*+TDR at the standard test temperatures, in BTU/h:

Certified matchups570 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 570 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CHX35-42C-**-*+TDREL280UH110E48C*16.813.58.017,600211001773
CK40HT-42C-0*+TDREL280UH110E48C*16.813.58.017,600214622448
CRX35-48C-**-*+TDRML180DF110E60C*16.613.08.718,800213257799
CK40DT-48C-0*+TDRML180DF110E60C*16.613.08.718,800214622593
CHX35-42C-**-*+TDRML180UH110V60C*16.613.58.118,200211001785
CHX35-42C-**-*+TDRML296UH110XV60C*16.613.58.118,100211001795
CHX35-42C-**-*+TDRSL280UH080NV60C*16.613.58.118,000211001796
CHX35-42C-**-*+TDRSL280UH100NV60C*16.613.58.118,400211001799
CHX35-42C-**-*+TDREL280UH110XE60C*16.613.58.118,100211001775
CHX35-42C-**-*+TDREL280UH110E60C*16.613.58.118,100211001774
CHX35-51/61C-**-*+TDREL280UH110E60C*16.613.58.117,500210293556
CHX35-51/61C-**-*+TDRSL280UH080NV60C*16.613.58.117,700210293578
CHX35-51/61C-**-*+TDRML180UH110V60C*16.613.58.117,700210293567
CHX35-51/61C-**-*+TDREL280UH110XE60C*16.613.58.117,500210293557
CK40HT-42C-0*+TDREL280UH110E60C*16.613.58.118,100214622449
CK40HT-42C-0*+TDREL280UH110XE60C*16.613.58.118,100214622450
CK40HT-42C-0*+TDRML180UH110V60C*16.613.58.118,200214622460
CK40HT-42C-0*+TDRML296UH110XV60C*16.613.58.118,100214622470
CK40HT-42C-0*+TDRSL280UH080NV60C*16.613.58.118,000214622471
CK40HT-42C-0*+TDRSL280UH100NV60C*16.613.58.118,400214622474
CK40HT-51/61C-0*+TDREL280UH110XE60C*16.613.58.117,500214622523
CK40HT-51/61C-0*+TDREL280UH110E60C*16.613.58.117,500214622522
CK40HT-51/61C-0*+TDRML180UH110V60C*16.613.58.117,700214622533
CK40HT-51/61C-0*+TDRSL280UH080NV60C*16.613.58.117,700214622544
CHX35-51/61C-**-*+TDRML180UH090E60C*16.613.58.017,400210293565
CHX35-51/61C-**-*+TDREL280UH110E48C*16.613.58.017,100210293555
CHX35-51/61C-**-*+TDRML296UH110XV60C*16.613.08.017,500210293577
CHX35-42C-**-*+TDREL196UH110XE60C*16.613.58.017,800211001772
CHX35-42C-**-*+TDRML193UH110XE48C*16.613.58.017,900211001788
CHX35-42C-**-*+TDRML196UH110XE60C*16.613.58.017,800211001793
CK40HT-42C-0*+TDREL196UH110XE60C*16.613.58.017,800214622447
CK40HT-42C-0*+TDRML193UH110XE48C*16.613.58.017,900214622463
CK40HT-42C-0*+TDRML196UH110XE60C*16.613.58.017,800214622468
CK40HT-51/61C-0*+TDREL280UH110E48C*16.613.58.017,100214622521
CK40HT-51/61C-0*+TDRML180UH090E60C*16.613.58.017,400214622531
CK40HT-51/61C-0*+TDRML296UH110XV60C*16.613.08.017,500214622543
CX35-36B+TDRML180UH090E48B*16.613.57.816,800210293654
C35-36B+TDR+TXVML180UH090E48B*16.613.57.816,800210293389
CK40CT-36B-0*+TDRML180UH090E48B*16.613.57.816,800214622636
CRX35-48C-**-*+TDRSL280DF110V60C*16.413.08.719,100213257806
CK40DT-48C-0*+TDRSL280DF110V60C*16.413.08.719,100214622600
CHX35-42C-**-*+TDRML180UH110E60C*16.413.58.118,000211001784
CHX35-42B-**-*+TDRML180UH090E48B*16.413.08.118,300211001752
CHX35-42B-**-*+TDRSL280UH080NV48B*16.413.58.118,400211001762
CHX35-51/61C-**-*+TDRML180UH110E60C*16.413.08.117,400210293566
CHX35-51/61C-**-*+TDRSL280UH100NV60C*16.413.08.117,800210293581
CK40HT-42B-0*+TDRML180UH090E48B*16.413.08.118,300214622426
CK40HT-42B-0*+TDRSL280UH080NV48B*16.413.58.118,400214622436
CK40HT-42C-0*+TDRML180UH110E60C*16.413.58.118,000214622459
CK40HT-51/61C-0*+TDRML180UH110E60C*16.413.08.117,400214622532
CK40HT-51/61C-0*+TDRSL280UH100NV60C*16.413.08.117,800214622547
C35-50/60C+TDR+TXVSL280UH080NV60C*16.413.08.017,200210293433
C35-50/60C+TDR+TXVML180UH110V60C*16.413.08.017,200210293422
C35-36B+TDR+TXVSL280UH080NV48B*16.413.08.017,000210293399
CX35-36B+TDRSL280UH080NV48B*16.413.08.017,000210293664
CX35-50/60C+TDRSL280UH080NV60C*16.413.08.017,200210293698
CHX35-51/61C-**-*+TDRML196UH110XE60C*16.413.08.017,500210293575
CHX35-51/61C-**-*+TDRML196UH090XE60C*16.413.08.017,300210293574
CX35-50/60C+TDRML180UH110V60C*16.413.08.017,200210293687
CHX35-51/61C-**-*+TDREL196UH110XE60C*16.413.08.017,500210293554
Yearly running cost in 10 large cities$1,004-$2,488

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Lennox EL17XP1-036-230A?
The Lennox EL17XP1-036-230A is rated at up to 16.8 SEER2 and 13.5 EER2 for cooling and up to 8.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 570 certified matchups SEER2 ranges from 15.2-16.8.
Is the Lennox EL17XP1-036-230A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Lennox EL17XP1-036-230A cost to run per year?
At its rated efficiency it costs about $1,004-$2,488 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,210 in Phoenix and $2,058 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Lennox EL17XP1-036-230A?
ENERGY STAR lists 570 certified combinations for this outdoor unit. The highest-rated ones use CHX35-42C-**-*+TDR, CK40HT-42C-0*+TDR, CRX35-48C-**-*+TDR.
What refrigerant does the Lennox EL17XP1-036-230A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,187/yrYou save $630/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Lennox EL17XP1-036-230A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,187
Current system, per year
$1,817
You save per year
$630
Payback
21.4 years
Net after 10 years
-$7,199

Cooling $754Heating $433Electricity used: 7,418 kWhSaved vs. a minimum-efficiency heat pump: $201

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.