HVAC Rated

3-ton central heat pump · Dlseries

Midea DLCURAH36ABK

Below average cooling efficiency and very good heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #225 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,075 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
10.0 Cooling efficiency on a 95°F day
Below average · beats 10%
Heat at 5°F
34,400 BTU/h86% of its 47°F output
Below average · beats 39%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 34,400 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 48 certified pairings.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications3 ton, R-410A
General
BrandMidea
Also sold asArcoaire, Comfortmaker, Day & Night, Heil, Keeprite, Tempstar, Airquest, Kenmore, Smart Comfort, LPS Legacy, Viessmann, Carrier, Bryant
Outdoor unit modelDLCURAH36ABK
SeriesDlseries
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 1, 2022
Last certifiedJune 9, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors10.0
Cooling capacity35,000-36,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.6-10.0
Capacity at 47°F38,000-40,000 BTU/h
Capacity at 17°F27,400-33,000 BTU/h
Capacity at 5°F31,600-34,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.85-2.00
ENERGY STAR cold climateYes
Heating output as it gets colder86% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with DLFUAAH36XAK at the standard test temperatures, in BTU/h:

Certified matchups48 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
DLFUAAH36XAK · cold climate16.010.09.534,400209852043
DLFUAAH36XAK · cold climate16.010.09.534,400209852054
DLFUAAH36XAK · cold climate16.010.09.534,400209852065
DLFUAAH36XAK · cold climate16.010.09.534,400209852076
DLFUAAH36XAK · cold climate16.010.09.534,400209852087
DLFUAAH36XAK · cold climate16.010.09.534,400209852098
DLFUAAH36XAK · cold climate16.010.09.534,400209852109
DLFUAAH36XAK · cold climate16.010.09.534,400209852120
DLFUAAH36XAK · cold climate16.010.09.534,400209852142
DLFUAAH36XAK · cold climate16.010.09.534,400209852131
DLFUAAH36XAK · cold climate16.010.09.534,400211756649
DLFUAAH36XAK · cold climate16.010.09.534,400215569761
40MUAAQ36XA3 · cold climate16.010.09.534,400216620166
40MUAAQ36XA3 · cold climate16.010.09.534,400216620178
40MUAAQ36XA3 · cold climate16.010.09.534,400216620190
40MUAAQ36XA3 · cold climate16.010.09.534,400216620202
40MUAAQ36XA3 · cold climate16.010.09.534,400216620214
40MUAAQ36XA3 · cold climate16.010.09.534,400216620226
40MUAAQ36XA3 · cold climate16.010.09.534,400216620238
40MUAAQ36XA3 · cold climate16.010.09.534,400216620250
40MUAAQ36XA3 · cold climate16.010.09.534,400216620262
40MUAAQ36XA3 · cold climate16.010.09.534,400216620274
DLFULAH36XBX + CI · cold climate15.510.08.631,600213372120
DLFULAH36XBX + CI · cold climate15.510.08.631,600213372128
DLFULAH36XBX + CI · cold climate15.510.08.631,600213372136
DLFULAH36XBX + CI · cold climate15.510.08.631,600213372144
DLFULAH36XBX + CI · cold climate15.510.08.631,600213372168
DLFULAH36XBX + CI · cold climate15.510.08.631,600213372200
DLFULAH36XBX + CI · cold climate15.510.08.631,600213372152
DLFULAH36XBX + CI · cold climate15.510.08.631,600213372176
DLFULAH36XBX + CI · cold climate15.510.08.631,600213372160
DLFULAH36XBX + CI · cold climate15.510.08.631,600213372184
DLFULAH36XBX + CI · cold climate15.510.08.631,600213372192
DLFULAH36XBX + CI · cold climate15.510.08.631,600215569768
DLFULAH36XBX · cold climate15.510.08.631,600217154268
DLFULAH36XCX + CI · cold climate15.210.010.032,000213372121
DLFULAH36XCX + CI · cold climate15.210.010.032,000213372129
DLFULAH36XCX + CI · cold climate15.210.010.032,000213372137
DLFULAH36XCX + CI · cold climate15.210.010.032,000213372145
DLFULAH36XCX + CI · cold climate15.210.010.032,000213372169
DLFULAH36XCX + CI · cold climate15.210.010.032,000213372153
DLFULAH36XCX + CI · cold climate15.210.010.032,000213372177
DLFULAH36XCX + CI · cold climate15.210.010.032,000213372161
DLFULAH36XCX + CI · cold climate15.210.010.032,000213372185
DLFULAH36XCX + CI · cold climate15.210.010.032,000213372193
DLFULAH36XCX + CI · cold climate15.210.010.032,000213372201
DLFULAH36XCX + CI · cold climate15.210.010.032,000215569769
DLFULAH36XCX · cold climate15.210.010.032,000217154269
Yearly running cost in 10 large cities$1,024-$2,518

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Midea DLCURAH36ABK?
The Midea DLCURAH36ABK is rated at up to 16.0 SEER2 and 10.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 48 certified matchups SEER2 ranges from 15.2-16.0.
Is the Midea DLCURAH36ABK good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 34,400 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Midea DLCURAH36ABK cost to run per year?
At its rated efficiency it costs about $1,024-$2,518 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,232 in Phoenix and $2,080 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Midea DLCURAH36ABK?
ENERGY STAR lists 48 certified combinations for this outdoor unit. The highest-rated ones use DLFUAAH36XAK, 40MUAAQ36XA3, DLFULAH36XBX + CI.
What refrigerant does the Midea DLCURAH36ABK use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,207/yrYou save $663/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Midea DLCURAH36ABK
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,207
Current system, per year
$1,870
You save per year
$663
Payback
19.6 years
Net after 10 years
-$6,367

Cooling $770Heating $437Electricity used: 7,543 kWhSaved vs. a minimum-efficiency heat pump: $237

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 9, 2026. How we use the data.