HVAC Rated

3.5-ton central heat pump · XD16H-LGWP

Midea MOVC-60HDN10-M16G

Average cooling efficiency and below average heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.

Ranks #37 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,429 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
39,500 BTU/h71% of its 47°F output
Below average · beats 20%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 39,500 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 21 certified pairings.

Think twice if…

  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandMidea
Outdoor unit modelMOVC-60HDN10-M16G
SeriesXD16H-LGWP
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableYes
On the market sinceSeptember 8, 2025
Last certifiedSeptember 22, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 16.0-17.0)
EER2Efficiency at 95°F outdoors10.0-11.7
Cooling capacity34,200-55,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5
Capacity at 47°F34,200-56,000 BTU/h
Capacity at 17°F33,000-40,000 BTU/h
Capacity at 5°F31,000-39,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-1.90
ENERGY STAR cold climateYes
Heating output as it gets colder71% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MVME48C2MN10TD at the standard test temperatures, in BTU/h:

Certified matchups21 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
MVME48C2MN10TD · cold climate-17.011.78.533,600217752267
MVME36B2MN10TD · cold climate-17.011.78.534,200217752268
MVME48C2MN10TB · cold climate-17.011.78.533,600217753640
MVME36B2MN10TB · cold climate-17.011.78.534,200217753641
MVME60C2MN10TD · cold climate-16.510.08.539,500217752321
MVME60C2MN10TB · cold climate-16.510.08.539,500217753645
MC**4248BN10TH · cold climateMGV97U080B3A16.010.58.531,000217752269
MC**4248CN10TH · cold climateMGV97U080C4A16.010.58.531,600217752270
MC**4248CN10TH · cold climateMGV97U100C5A16.010.58.533,000217752271
MC**4248DN10TH · cold climateMGV97U100D5A16.010.58.533,000217752272
MC**4248DN10TH · cold climateMGV97U120D5A16.010.58.533,000217752273
MC**4248CN10TH+MEME10C5B · cold climate-16.010.58.533,000217752504
MC**4248BN10TH+MEME05B4B · cold climate-16.010.58.531,000217752503
MC**4248DN10TH+MEME10D5B · cold climate-16.010.58.533,000217752505
MC**4248BN10TH · cold climateMGV96U080B3C16.010.58.531,000217752874
MC**4248CN10TH · cold climateMGV96U080C4C16.010.58.531,600217752875
MC**4248DN10TH · cold climateMGV96U100D5C16.010.58.533,000217752877
MC**4248CN10TH · cold climateMGV96U100C5C16.010.58.533,000217752876
MC**4248DN10TH · cold climateMGV96U120D5C16.010.58.533,000217752878
MC**4248CN10TH · cold climateY82E080C16LMPS116.010.58.532,200218743968
MC**4248CN10TH · cold climateBGK80A080C4A16.010.58.532,200218743963
Yearly running cost in 10 large cities$1,233-$3,454

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Midea MOVC-60HDN10-M16G?
The Midea MOVC-60HDN10-M16G is rated at up to 17.0 SEER2 and 11.7 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 21 certified matchups SEER2 ranges from 16.0-17.0.
Is the Midea MOVC-60HDN10-M16G good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 39,500 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
How much does the Midea MOVC-60HDN10-M16G cost to run per year?
At its rated efficiency it costs about $1,233-$3,454 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,541 in Phoenix and $2,902 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Midea MOVC-60HDN10-M16G?
ENERGY STAR lists 21 certified combinations for this outdoor unit. The highest-rated ones use MVME48C2MN10TD, MVME36B2MN10TD, MVME48C2MN10TB.
What refrigerant does the Midea MOVC-60HDN10-M16G use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,541/yrYou save $795/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Midea MOVC-60HDN10-M16G
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,541
Current system, per year
$2,335
You save per year
$795
Payback
20.8 years
Net after 10 years
-$8,553

Cooling $921Heating $619Electricity used: 9,629 kWhSaved vs. a minimum-efficiency heat pump: $257

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 22, 2026. How we use the data.