3-ton central heat pump · LEA Series
NOVAIR LEA36CEN36-O
Average cooling efficiency and excellent heating efficiency for a 3-ton central heat pump, and certified for cold climates.
Ranks #95 of 302 3 ton central heat pumps for cooling efficiency, and costs about $987 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.0 Cooling efficiency over a seasonAverage · beats 66%
- HSPF2
- 10.3 Heating efficiency over a seasonExcellent · beats 92%
- EER2
- 12.0 Cooling efficiency on a 95°F dayAverage · beats 64%
- Heat at 5°F
- 39,000 BTU/h101% of its 47°F outputBelow average · beats 20%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 39,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 92% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | NOVAIR |
| Outdoor unit model | LEA36CEN36-O |
| Series | LEA Series |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | July 18, 2025 |
| Last certified | September 30, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.0 (range 15.2-18.0) |
| EER2Efficiency at 95°F outdoors | 10.5-12.0 |
| Cooling capacity | 35,000-36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.8-10.3 |
| Capacity at 47°F | 36,000-38,000 BTU/h |
| Capacity at 17°F | 28,000-33,000 BTU/h |
| Capacity at 5°F | 33,000-39,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.75-1.90 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with LEA36HH-CEN-I at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| LEA36HH-CEN-I · cold climate | - | 18.0 | 12.0 | 10.0 | 37,400 | 218788026 |
| LEA36CEN36-I · cold climate | - | 17.4 | 11.7 | 10.3 | 39,000 | 217606256 |
| LEA-30/36ACOIL17.5*21*24 · cold climate | - | 15.8 | 10.7 | 9.4 | 36,000 | 217606326 |
| LEA-30/36ACOIL21*21*24 · cold climate | - | 15.8 | 10.7 | 9.4 | 36,000 | 217606327 |
| LEA-30/36ACOIL17.5*21*24 · cold climate | C60-2-V | 15.3 | 10.5 | 8.8 | 33,000 | 218799852 |
| LEA-30/36ACOIL21*21*24 · cold climate | C120-M-V | 15.2 | 10.6 | 9.3 | 34,000 | 218799854 |
| LEA-30/36ACOIL21*21*24 · cold climate | C105-M-V | 15.2 | 10.7 | 9.2 | 34,000 | 218799853 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,129/yr
- Miami, FL$937/yr
- Houston, TX$1,011/yr
- Atlanta, GA$987/yr
- Los Angeles, CA$953/yr
- New York, NY$2,316/yr
- Chicago, IL$1,872/yr
- Denver, CO$1,549/yr
- Seattle, WA$947/yr
- Minneapolis, MN$1,915/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the NOVAIR LEA36CEN36-O?
- The NOVAIR LEA36CEN36-O is rated at up to 18.0 SEER2 and 12.0 EER2 for cooling and up to 10.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 7 certified matchups SEER2 ranges from 15.2-18.0.
- Is the NOVAIR LEA36CEN36-O good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 39,000 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the NOVAIR LEA36CEN36-O cost to run per year?
- At its rated efficiency it costs about $937-$2,316 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,129 in Phoenix and $1,915 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the NOVAIR LEA36CEN36-O?
- ENERGY STAR lists 7 certified combinations for this outdoor unit. The highest-rated ones use LEA36HH-CEN-I, LEA36CEN36-I, LEA-30/36ACOIL17.5*21*24.
- What refrigerant does the NOVAIR LEA36CEN36-O use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- MOOVAIR MSHMB36R2AN1 · cold climate18.0 SEER2 · 10.3 HSPF2
- 1HVAC ACIQ-36-HP32 · cold climate18.0 SEER2 · 10.0 HSPF2
- Midea MO1SE-H36B-2A · cold climate18.0 SEER2 · 10.3 HSPF2
- Cooper&Hunter CH-PQ36X-230VO · cold climate18.0 SEER2 · 10.0 HSPF2
- MDV MOX630-36HFN10-M3X · cold climate18.0 SEER2 · 10.3 HSPF2
- MDV MOE30-36HFN10-M3X · cold climate18.0 SEER2 · 10.0 HSPF2
- Mainline ML36HP230LMNTH-O · cold climate18.0 SEER2 · 10.3 HSPF2
- MRCOOL UHP18036-O · cold climate18.0 SEER2 · 10.0 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.