Ranks #216 of 331 2 ton central heat pumps for cooling efficiency, and costs about $699 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.0 Cooling efficiency over a seasonAverage · beats 49%
- HSPF2
- 10.2 Heating efficiency over a seasonExcellent · beats 91%
- EER2
- 10.5 Cooling efficiency on a 95°F dayBelow average · beats 17%
- Heat at 5°F
- 19,400 BTU/h75% of its 47°F outputExcellent · beats 91%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 19,400 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 91% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 15 certified pairings.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | PolarWave |
| Also sold as | STEALTH, DIYCOOL, ACIQ, 1HVAC |
| Outdoor unit model | ACIQ-24-EHPB |
| Series | ACIQ series |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | April 26, 2023 |
| Last certified | June 9, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.0 (range 15.7-17.0) |
| EER2Efficiency at 95°F outdoors | 10.0-10.5 |
| Cooling capacity | 24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.2-10.2 |
| Capacity at 47°F | 25,600-26,000 BTU/h |
| Capacity at 17°F | 19,500-22,000 BTU/h |
| Capacity at 5°F | 18,500-19,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.10-2.33 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ACIQ-24W-WM at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| ACIQ-24W-WM · cold climate | 17.0 | 10.5 | 10.2 | 19,400 | 213433264 |
| ACIQ-24W-WM · cold climate | 17.0 | 10.5 | 10.2 | 19,400 | 213433283 |
| ACIQ-24W-WM · cold climate | 17.0 | 10.5 | 10.2 | 19,400 | 213433302 |
| ACIQ-24W-WM · cold climate | 17.0 | 10.5 | 10.2 | 19,400 | 213433226 |
| ACIQ-24W-WM · cold climate | 17.0 | 10.5 | 10.2 | 19,400 | 213433245 |
| ACIQ-24-AHB · cold climate | 17.0 | 10.5 | 9.2 | 19,400 | 213433238 |
| ACIQ-24-AHB · cold climate | 17.0 | 10.5 | 9.2 | 19,400 | 213433219 |
| ACIQ-24-AHB · cold climate | 17.0 | 10.5 | 9.2 | 19,400 | 213433257 |
| ACIQ-24-AHB · cold climate | 17.0 | 10.5 | 9.2 | 19,400 | 213433276 |
| ACIQ-24-AHB · cold climate | 17.0 | 10.5 | 9.2 | 19,400 | 213433295 |
| ACIQ-24-ACL · cold climate | 15.7 | 10.0 | 9.8 | 18,500 | 212394339 |
| ACIQ-24-ACL · cold climate | 15.7 | 10.0 | 9.8 | 18,500 | 212394350 |
| ACIQ-24-ACL · cold climate | 15.7 | 10.0 | 9.8 | 18,500 | 212394328 |
| ACIQ-24-ACL · cold climate | 15.7 | 10.0 | 9.8 | 18,500 | 212394317 |
| ACIQ-24-ACL · cold climate | 15.7 | 10.0 | 9.8 | 18,500 | 212394306 |
Yearly running cost in 10 large cities
- Phoenix, AZ$798/yr
- Miami, FL$661/yr
- Houston, TX$714/yr
- Atlanta, GA$699/yr
- Los Angeles, CA$675/yr
- New York, NY$1,642/yr
- Chicago, IL$1,327/yr
- Denver, CO$1,099/yr
- Seattle, WA$672/yr
- Minneapolis, MN$1,358/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the PolarWave ACIQ-24-EHPB?
- The PolarWave ACIQ-24-EHPB is rated at up to 17.0 SEER2 and 10.5 EER2 for cooling and up to 10.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 15 certified matchups SEER2 ranges from 15.7-17.0.
- Is the PolarWave ACIQ-24-EHPB good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 19,400 BTU/h at 5°F with a COP of 2.33, so it is still 2.3 times as efficient as electric resistance heat at that temperature.
- How much does the PolarWave ACIQ-24-EHPB cost to run per year?
- At its rated efficiency it costs about $661-$1,642 a year in electricity in large U.S. cities, depending on climate and local rates - for example $798 in Phoenix and $1,358 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the PolarWave ACIQ-24-EHPB?
- ENERGY STAR lists 15 certified combinations for this outdoor unit. The highest-rated ones use ACIQ-24W-WM, ACIQ-24-AHB, ACIQ-24-ACL.
- What refrigerant does the PolarWave ACIQ-24-EHPB use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Multi MFG HES-24HD-A · cold climate17.0 SEER2 · 10.2 HSPF2
- Carrier 38MURAQ24AA3 · cold climate17.0 SEER2 · 9.8 HSPF2
- Innovair SEV24H2R19 · cold climate17.0 SEER2 · 10.2 HSPF2
- ComfortStar CPR24CD(O) · cold climate17.0 SEER2 · 9.8 HSPF2
- Trane 4TWV7X24A117.1 SEER2 · 8.5 HSPF2
- Midea DLCURAH24AAK · cold climate17.0 SEER2 · 9.8 HSPF2
- Trane 5TWR7024A1 · cold climate17.1 SEER2 · 11.0 HSPF2
- Panasonic CU-E24YAHK6 · cold climate17.0 SEER2 · 9.8 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 9, 2026. How we use the data.