3-ton central heat pump · SmartSense 23 VS HP

Tempstar B5H3V36*K*AAA

Excellent cooling efficiency and very good heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #6 of 302 3 ton central heat pumps for cooling efficiency, and costs about $956 a year to run in a mixed climate like Atlanta.

SEER2
22.5 Cooling efficiency over a season
Excellent · beats 99%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
12.5 Cooling efficiency on a 95°F day
Very good · beats 80%
Heat at 5°F
29,600 BTU/h75% of its 47°F output
Average · beats 58%

A good fit if…

  • You want low cooling bills - its SEER2 beats 99% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 29,600 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandTempstar
Also sold asKenmore, Keeprite, Day & Night, Comfortmaker, Arcoaire, Airquest, Heil, ACIQ
Outdoor unit modelB5H3V36*K*AAA
SeriesSmartSense 23 VS HP
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedAugust 5, 2026
Cooling
SEER2Seasonal efficiency, higher is better22.5 (range 18.0-22.5)
EER2Efficiency at 95°F outdoors10.0-12.5
Cooling capacity32,000-36,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-9.5
Capacity at 47°F33,400-39,500 BTU/h
Capacity at 17°F29,200-34,800 BTU/h
Capacity at 5°F25,200-29,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.92-2.10
ENERGY STAR cold climateYes
Heating output as it gets colder75% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EVM5X61M24A*+WALLCON at the standard test temperatures, in BTU/h:

Certified matchups4,626 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 4,626 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*22.512.58.528,200218411807
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*22.512.58.528,200218411806
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*22.512.58.528,200218411805
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*22.512.58.528,200218411804
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*22.512.58.528,200218411803
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*22.512.58.528,200218411802
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*22.512.58.528,200218411801
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*22.512.58.528,200218411800
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218411799
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218411798
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218411797
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218411796
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218411795
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218411794
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218411793
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218411792
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218411791
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218411790
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218411789
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218411788
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218411787
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218411786
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218411785
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218411784
EVD5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200218413151
EVD5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200218413150
EVD5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200218413149
EVD5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200218413148
EVD5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200218413147
EVD5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200218413146
EVD5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200218413145
EVD5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200218413144
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218413143
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218413142
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218413141
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218413140
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218413139
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218413138
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218413137
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218413136
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218413135
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218413134
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218413133
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218413132
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218413131
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218413130
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218413129
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218413128
EVD5X61M24A*+WALLCON · cold climate*95CSU1002122B*22.512.58.528,200218629661
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218629660
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218629659
EVM5X61M24A*+WALLCON · cold climate*80CTL1352422B*22.512.58.528,200218629494
EVM5X61M24A*+WALLCON · cold climate*80CTL1102120B*22.512.58.528,200218629493
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*22.512.58.528,200218629492
FCMA5B60L0D*+WALLCON · cold climate-22.012.59.525,200218405887
FCMA5B60L0D*+WALLCON · cold climate-22.012.59.525,200218405886
FCMA5B60L0D*+WALLCON · cold climate-22.012.59.525,200218405885
FCMA5B60L0D*+WALLCON · cold climate-22.012.59.525,200218405884
FCMA5B60L0D*+WALLCON · cold climate-22.012.59.525,200218405883
FCMA5B60L0D*+WALLCON · cold climate-22.012.59.525,200218405882
Yearly running cost in 10 large cities$726-$2,389

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Tempstar B5H3V36*K*AAA?
The Tempstar B5H3V36*K*AAA is rated at up to 22.5 SEER2 and 12.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4626 certified matchups SEER2 ranges from 18.0-22.5.
Is the Tempstar B5H3V36*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 29,600 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Tempstar B5H3V36*K*AAA cost to run per year?
At its rated efficiency it costs about $726-$2,389 a year in electricity in large U.S. cities, depending on climate and local rates - for example $957 in Phoenix and $2,044 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Tempstar B5H3V36*K*AAA?
ENERGY STAR lists 4626 certified combinations for this outdoor unit. The highest-rated ones use EVM5X61M24A*+WALLCON, EVD5X61M24A*+WALLCON, FCMA5B60L0D*+WALLCON.
What refrigerant does the Tempstar B5H3V36*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $981/yrYou save $845/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Tempstar B5H3V36*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$981
Current system, per year
$1,826
You save per year
$845
Payback
15.4 years
Net after 10 years
-$4,553

Cooling $538Heating $443Electricity used: 6,134 kWhSaved vs. a minimum-efficiency heat pump: $427

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 5, 2026. How we use the data.