2-ton central heat pump · MAINLINE 16 SEER2 HP
Tempstar T5H6S24*K*AAA
Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #262 of 331 2 ton central heat pumps for cooling efficiency, and costs about $723 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.5 Cooling efficiency over a seasonAverage · beats 40%
- HSPF2
- 8.5 Heating efficiency over a seasonBelow average · beats 38%
- EER2
- 13.0 Cooling efficiency on a 95°F dayVery good · beats 89%
- Heat at 5°F
- 11,900 BTU/h49% of its 47°F outputVery good · beats 83%
A good fit if…
- You want a choice of indoor units - 193 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Tempstar |
| Also sold as | Kenmore |
| Outdoor unit model | T5H6S24*K*AAA |
| Series | MAINLINE 16 SEER2 HP |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | January 1, 2024 |
| Last certified | July 16, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.5 (range 15.2-16.5) |
| EER2Efficiency at 95°F outdoors | 11.7-13.0 |
| Cooling capacity | 22,200-24,400 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.5 |
| Capacity at 47°F | 21,600-24,000 BTU/h |
| Capacity at 17°F | 14,200-15,200 BTU/h |
| Capacity at 5°F | 10,800-11,900 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.98-2.26 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FMA5X30**AL at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 193 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| FMA5X30**AL | - | 16.5 | 13.0 | 8.5 | 11,600 | 214424130 |
| EA*5X37M21A | *97VTN1002120A* | 16.0 | 12.5 | 8.0 | 11,500 | 215802392 |
| EA*5X37M21A | *97VTN1002122A* | 16.0 | 13.0 | 8.0 | 11,400 | 215802400 |
| EVM5X31M17A | *80MSU0601716A* | 16.0 | 12.0 | 7.8 | 11,200 | 214161404 |
| EVM5X32M17A | *92MSN0801716A* | 16.0 | 12.0 | 7.8 | 11,200 | 214161572 |
| EVM5X32M17A | *80MS(N,L)0901714A* | 16.0 | 12.0 | 7.8 | 11,200 | 214161452 |
| EVM5X32M17A | *80VSL0901716B* | 16.0 | 12.0 | 7.8 | 11,400 | 214161484 |
| EVM5X32M17A | *80MSU0601716A* | 16.0 | 12.5 | 7.8 | 11,300 | 214161508 |
| EVD5X31M17A | *80MSU0601716A* | 16.0 | 12.5 | 7.8 | 11,200 | 214161644 |
| EVD5X37M21A | *80MS(N,L)0902116A* | 16.0 | 12.0 | 7.8 | 11,200 | 214161676 |
| EA*5X25M17A | *80MSU0401712A* | 16.0 | 12.5 | 7.8 | 11,300 | 214160908 |
| EA*5X25M17A | *80MSU0601716A* | 16.0 | 12.0 | 7.8 | 11,200 | 214160916 |
| EA*5X25M17A | *80CTL0701412B* | 16.0 | 12.5 | 7.8 | 11,400 | 214160932 |
| EVD5X38M17A | *80VSL0701716B* | 16.0 | 12.0 | 7.8 | 11,300 | 214161868 |
| EVD5X38M17A | *80VSL0901716B* | 16.0 | 12.5 | 7.8 | 11,400 | 214161876 |
| EVD5X38M17A | *80MS(N,L)0701712A* | 16.0 | 12.5 | 7.8 | 11,400 | 214161828 |
| EVD5X38M17A | *80MS(N,L)0701716A* | 16.0 | 12.0 | 7.8 | 11,400 | 214161836 |
| EVD5X38M17A | *80MS(N,L)0901714A* | 16.0 | 12.5 | 7.8 | 11,200 | 214161844 |
| EA*5X37M21A | *80CSU0401712A* | 16.0 | 12.5 | 7.8 | 11,200 | 214160996 |
| EA*5X37M21A | *80CSU0802120A* | 16.0 | 12.5 | 7.8 | 11,300 | 214161004 |
| EVD5X31M17A | *80VSL0901716B* | 16.0 | 12.0 | 7.8 | 11,300 | 214159417 |
| EA*5X37M21A | *95CSU1002122B* | 16.0 | 12.5 | 7.8 | 11,600 | 214161180 |
| EA*5X37M21A | *80CTL0902120B* | 16.0 | 12.5 | 7.8 | 11,500 | 214161148 |
| EA*5X37M21A | *80VTL1102122B* | 16.0 | 12.0 | 7.8 | 11,500 | 214161164 |
| EA*5X37M21A | *97CMN1002122A* | 16.0 | 12.5 | 7.8 | 11,200 | 214161188 |
| EA*5X37M21A | *97CMN0802120B* | 16.0 | 12.5 | 7.8 | 11,500 | 214161196 |
| EA*5X37M21A | *97CMN1002122B* | 16.0 | 12.5 | 7.8 | 11,500 | 214161204 |
| EA*5X37M21A | *95MSU1002120A* | 16.0 | 12.0 | 7.8 | 11,500 | 214161300 |
| EA*5X37M21A | *96CTN1002122A* | 16.0 | 12.5 | 7.8 | 11,200 | 214161316 |
| EA*5X37M21A | *96CTN0802120B* | 16.0 | 12.5 | 7.8 | 11,500 | 214161324 |
| EA*5X37M21A | *96CTN1002122B* | 16.0 | 12.5 | 7.8 | 11,500 | 214161332 |
| EVD5X38M17A | *80MSU0601716A* | 16.0 | 12.5 | 7.8 | 11,300 | 214161900 |
| EVD5X38M17A | *80VTL0701716B* | 16.0 | 12.0 | 7.8 | 11,400 | 214161932 |
| EVD5X38M17A | *92MSN0601714A* | 16.0 | 12.0 | 7.8 | 11,400 | 214161964 |
| FM(C,U)5Z30**AL | - | 16.0 | 12.5 | 7.8 | 11,100 | 215829006 |
| FM(C,U)5Z36**AL | - | 16.0 | 12.5 | 7.8 | 11,100 | 215829014 |
| EA*5X37M21A*+WALLCON | *80CTL0902120B* | 16.0 | 12.5 | 7.8 | 11,500 | 217006699 |
| EA*5X37M21A*+WALLCON | *95CSU1002122B* | 16.0 | 12.5 | 7.8 | 11,600 | 217006715 |
| EA*5X25M17A*+WALLCON | *80CTL0701412B* | 16.0 | 12.5 | 7.8 | 11,400 | 217006683 |
| EA*5X37M21A*+WALLCON | *97CMN0802120B* | 16.0 | 12.5 | 7.8 | 11,500 | 217006723 |
| EA*5X37M21A*+WALLCON | *97CMN1002122B* | 16.0 | 12.5 | 7.8 | 11,500 | 217006731 |
| EA*5X37M21A*+WALLCON | *96CTN1002122B* | 16.0 | 12.5 | 7.8 | 11,500 | 217006739 |
| EA*5X37M21A*+WALLCON | *96CTN0802120B* | 16.0 | 12.5 | 7.8 | 11,500 | 215802328 |
| FM(C,U)5Z24**AL | - | 15.5 | 12.0 | 8.0 | 11,300 | 215828998 |
| FEVA0036**+NAVA53601CK | - | 15.5 | 12.0 | 8.0 | 11,300 | 217051558 |
| EVM5X32M17A | *80MS(N,L)0701712A* | 15.5 | 12.0 | 7.8 | 11,400 | 214161436 |
| EVM5X32M17A | *80MS(N,L)0701716A* | 15.5 | 12.0 | 7.8 | 11,400 | 214161444 |
| EA*5X25M17A | *97CMN0801714B* | 15.5 | 12.0 | 7.8 | 11,500 | 214157472 |
| EVM5X32M17A | *80VTL0701716B* | 15.5 | 12.0 | 7.8 | 11,400 | 214161540 |
| EVM5X32M17A | *95MSU0601716A* | 15.5 | 12.0 | 7.8 | 11,400 | 214161580 |
| EA*5X37M17A | *97CMN0801714B* | 15.5 | 12.0 | 7.8 | 11,300 | 214158176 |
| EA*5X37M17A | *95CSU0601716B* | 15.5 | 12.0 | 7.8 | 11,300 | 214158144 |
| EA*5X37M17A | *97CMN0601714B* | 15.5 | 12.0 | 7.8 | 11,400 | 214158168 |
| EVM5X32M17A | *80VSL0701716B* | 15.5 | 12.0 | 7.8 | 11,300 | 214161476 |
| EA*5X37M17A | *80MSU0401712A* | 15.5 | 12.5 | 7.8 | 11,300 | 214158056 |
| EA*5X37M21A | *96CTN0801714B* | 15.5 | 12.0 | 7.8 | 11,600 | 214158856 |
| EA*5X37M17A | *80CTL0701412B* | 15.5 | 12.0 | 7.8 | 11,200 | 214158080 |
| EA*5X37M17A | *80CTL0701716B* | 15.5 | 12.0 | 7.8 | 11,300 | 214158088 |
| EA*5X37M17A | *80CTL0901716B* | 15.5 | 12.0 | 7.8 | 11,300 | 214158096 |
| EA*5X37M21A | OLV112A16A | 15.5 | 12.0 | 7.8 | 11,500 | 214158928 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the Tempstar T5H6S24*K*AAA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Kenmore (C,H,T)5H6S24*K*AAA
Yearly running cost in 10 large cities
- Phoenix, AZ$819/yr
- Miami, FL$676/yr
- Houston, TX$734/yr
- Atlanta, GA$723/yr
- Los Angeles, CA$700/yr
- New York, NY$1,705/yr
- Chicago, IL$1,380/yr
- Denver, CO$1,143/yr
- Seattle, WA$700/yr
- Minneapolis, MN$1,413/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Tempstar T5H6S24*K*AAA?
- The Tempstar T5H6S24*K*AAA is rated at up to 16.5 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 193 certified matchups SEER2 ranges from 15.2-16.5.
- Is the Tempstar T5H6S24*K*AAA good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the Tempstar T5H6S24*K*AAA cost to run per year?
- At its rated efficiency it costs about $676-$1,705 a year in electricity in large U.S. cities, depending on climate and local rates - for example $819 in Phoenix and $1,413 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Tempstar T5H6S24*K*AAA the same as the Kenmore (C,H,T)5H6S24*K*AAA?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the Tempstar T5H6S24*K*AAA?
- ENERGY STAR lists 193 certified combinations for this outdoor unit. The highest-rated ones use FMA5X30**AL, EA*5X37M21A, EVM5X31M17A.
- What refrigerant does the Tempstar T5H6S24*K*AAA use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- WeatherMaker PH5SAN524**AB16.5 SEER2 · 8.5 HSPF2
- Heil H5H6S24*K*AAA16.5 SEER2 · 8.5 HSPF2
- Samsung AC024FCUDCG · cold climate16.5 SEER2 · 8.2 HSPF2
- Heil B5H6S24*K*AAA16.5 SEER2 · 8.5 HSPF2
- Grandaire W4H7T24*K*AAA16.5 SEER2 · 8.1 HSPF2
- Grandaire W5H5S24*K*AAA16.5 SEER2 · 8.5 HSPF2
- Samsung AC024BXUPCH · cold climate16.5 SEER2 · 8.1 HSPF2
- Carrier GH5SAN524**AA16.5 SEER2 · 8.5 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.