HVAC Rated

2-ton central heat pump · MAINLINE 16 SEER2 HP

Tempstar T5H6S24*K*AAA

Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #262 of 331 2 ton central heat pumps for cooling efficiency, and costs about $723 a year to run in a mixed climate like Atlanta.

SEER2
16.5 Cooling efficiency over a season
Average · beats 40%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
11,900 BTU/h49% of its 47°F output
Very good · beats 83%

A good fit if…

  • You want a choice of indoor units - 193 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandTempstar
Also sold asKenmore
Outdoor unit modelT5H6S24*K*AAA
SeriesMAINLINE 16 SEER2 HP
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 1, 2024
Last certifiedJuly 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.5 (range 15.2-16.5)
EER2Efficiency at 95°F outdoors11.7-13.0
Cooling capacity22,200-24,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F21,600-24,000 BTU/h
Capacity at 17°F14,200-15,200 BTU/h
Capacity at 5°F10,800-11,900 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.98-2.26
ENERGY STAR cold climateNo
Heating output as it gets colder49% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FMA5X30**AL at the standard test temperatures, in BTU/h:

Certified matchups193 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 193 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FMA5X30**AL-16.513.08.511,600214424130
EA*5X37M21A*97VTN1002120A*16.012.58.011,500215802392
EA*5X37M21A*97VTN1002122A*16.013.08.011,400215802400
EVM5X31M17A*80MSU0601716A*16.012.07.811,200214161404
EVM5X32M17A*92MSN0801716A*16.012.07.811,200214161572
EVM5X32M17A*80MS(N,L)0901714A*16.012.07.811,200214161452
EVM5X32M17A*80VSL0901716B*16.012.07.811,400214161484
EVM5X32M17A*80MSU0601716A*16.012.57.811,300214161508
EVD5X31M17A*80MSU0601716A*16.012.57.811,200214161644
EVD5X37M21A*80MS(N,L)0902116A*16.012.07.811,200214161676
EA*5X25M17A*80MSU0401712A*16.012.57.811,300214160908
EA*5X25M17A*80MSU0601716A*16.012.07.811,200214160916
EA*5X25M17A*80CTL0701412B*16.012.57.811,400214160932
EVD5X38M17A*80VSL0701716B*16.012.07.811,300214161868
EVD5X38M17A*80VSL0901716B*16.012.57.811,400214161876
EVD5X38M17A*80MS(N,L)0701712A*16.012.57.811,400214161828
EVD5X38M17A*80MS(N,L)0701716A*16.012.07.811,400214161836
EVD5X38M17A*80MS(N,L)0901714A*16.012.57.811,200214161844
EA*5X37M21A*80CSU0401712A*16.012.57.811,200214160996
EA*5X37M21A*80CSU0802120A*16.012.57.811,300214161004
EVD5X31M17A*80VSL0901716B*16.012.07.811,300214159417
EA*5X37M21A*95CSU1002122B*16.012.57.811,600214161180
EA*5X37M21A*80CTL0902120B*16.012.57.811,500214161148
EA*5X37M21A*80VTL1102122B*16.012.07.811,500214161164
EA*5X37M21A*97CMN1002122A*16.012.57.811,200214161188
EA*5X37M21A*97CMN0802120B*16.012.57.811,500214161196
EA*5X37M21A*97CMN1002122B*16.012.57.811,500214161204
EA*5X37M21A*95MSU1002120A*16.012.07.811,500214161300
EA*5X37M21A*96CTN1002122A*16.012.57.811,200214161316
EA*5X37M21A*96CTN0802120B*16.012.57.811,500214161324
EA*5X37M21A*96CTN1002122B*16.012.57.811,500214161332
EVD5X38M17A*80MSU0601716A*16.012.57.811,300214161900
EVD5X38M17A*80VTL0701716B*16.012.07.811,400214161932
EVD5X38M17A*92MSN0601714A*16.012.07.811,400214161964
FM(C,U)5Z30**AL-16.012.57.811,100215829006
FM(C,U)5Z36**AL-16.012.57.811,100215829014
EA*5X37M21A*+WALLCON*80CTL0902120B*16.012.57.811,500217006699
EA*5X37M21A*+WALLCON*95CSU1002122B*16.012.57.811,600217006715
EA*5X25M17A*+WALLCON*80CTL0701412B*16.012.57.811,400217006683
EA*5X37M21A*+WALLCON*97CMN0802120B*16.012.57.811,500217006723
EA*5X37M21A*+WALLCON*97CMN1002122B*16.012.57.811,500217006731
EA*5X37M21A*+WALLCON*96CTN1002122B*16.012.57.811,500217006739
EA*5X37M21A*+WALLCON*96CTN0802120B*16.012.57.811,500215802328
FM(C,U)5Z24**AL-15.512.08.011,300215828998
FEVA0036**+NAVA53601CK-15.512.08.011,300217051558
EVM5X32M17A*80MS(N,L)0701712A*15.512.07.811,400214161436
EVM5X32M17A*80MS(N,L)0701716A*15.512.07.811,400214161444
EA*5X25M17A*97CMN0801714B*15.512.07.811,500214157472
EVM5X32M17A*80VTL0701716B*15.512.07.811,400214161540
EVM5X32M17A*95MSU0601716A*15.512.07.811,400214161580
EA*5X37M17A*97CMN0801714B*15.512.07.811,300214158176
EA*5X37M17A*95CSU0601716B*15.512.07.811,300214158144
EA*5X37M17A*97CMN0601714B*15.512.07.811,400214158168
EVM5X32M17A*80VSL0701716B*15.512.07.811,300214161476
EA*5X37M17A*80MSU0401712A*15.512.57.811,300214158056
EA*5X37M21A*96CTN0801714B*15.512.07.811,600214158856
EA*5X37M17A*80CTL0701412B*15.512.07.811,200214158080
EA*5X37M17A*80CTL0701716B*15.512.07.811,300214158088
EA*5X37M17A*80CTL0901716B*15.512.07.811,300214158096
EA*5X37M21AOLV112A16A15.512.07.811,500214158928
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Tempstar T5H6S24*K*AAA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$676-$1,705

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Tempstar T5H6S24*K*AAA?
The Tempstar T5H6S24*K*AAA is rated at up to 16.5 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 193 certified matchups SEER2 ranges from 15.2-16.5.
Is the Tempstar T5H6S24*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Tempstar T5H6S24*K*AAA cost to run per year?
At its rated efficiency it costs about $676-$1,705 a year in electricity in large U.S. cities, depending on climate and local rates - for example $819 in Phoenix and $1,413 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Tempstar T5H6S24*K*AAA the same as the Kenmore (C,H,T)5H6S24*K*AAA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Tempstar T5H6S24*K*AAA?
ENERGY STAR lists 193 certified combinations for this outdoor unit. The highest-rated ones use FMA5X30**AL, EA*5X37M21A, EVM5X31M17A.
What refrigerant does the Tempstar T5H6S24*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $806/yrYou save $402/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Tempstar T5H6S24*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$806
Current system, per year
$1,208
You save per year
$402
Payback
22.4 years
Net after 10 years
-$4,980

Cooling $508Heating $298Electricity used: 5,035 kWhSaved vs. a minimum-efficiency heat pump: $118

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.