HVAC Rated

12,000 BTU mini-split heat pump · M series

TGM MRSVHT12AS

Average cooling and heating efficiency for a 12,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #273 of 394 12,000 BTU mini-splits for cooling efficiency, and costs about $292 a year to run in a mixed climate like Atlanta.

SEER2
22.7 Cooling efficiency over a season
Average · beats 57%
HSPF2
10.3 Heating efficiency over a season
Average · beats 55%
EER2
14.0 Cooling efficiency on a 95°F day
Very good · beats 82%
Heat at 5°F
8,400 BTU/h67% of its 47°F output
Very good · beats 84%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 8,400 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications12,000 BTU, R-410A
General
BrandTGM
Also sold asCLASSIC
Outdoor unit modelMRSVHT12AS
SeriesM series
TypeMini-split heat pump
Nominal size12,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceAugust 18, 2022
Last certifiedMay 6, 2026
Cooling
SEER2Seasonal efficiency, higher is better22.7 (range 19.0-22.7)
EER2Efficiency at 95°F outdoors11.7-14.0
Cooling capacity11,500-12,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.0-10.3
Capacity at 47°F12,000 BTU/h
Capacity at 17°F8,900-9,300 BTU/h
Capacity at 5°F8,000-8,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.26-2.27
ENERGY STAR cold climateYes
Heating output as it gets colder67% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MC4VHT12S at the standard test temperatures, in BTU/h:

Certified matchups3 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
MC4VHT12S22.714.010.08,000209843012
MFCHT12S · cold climate19.011.710.38,400209843017
MFCHT12S · cold climate19.011.710.38,400209843017
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the TGM MRSVHT12AS: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$239-$717

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the TGM MRSVHT12AS?
The TGM MRSVHT12AS is rated at up to 22.7 SEER2 and 14.0 EER2 for cooling and up to 10.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 19.0-22.7.
Is the TGM MRSVHT12AS good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 8,400 BTU/h at 5°F with a COP of 2.27, so it is still 2.3 times as efficient as electric resistance heat at that temperature.
How much does the TGM MRSVHT12AS cost to run per year?
At its rated efficiency it costs about $239-$717 a year in electricity in large U.S. cities, depending on climate and local rates - for example $306 in Phoenix and $607 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the TGM MRSVHT12AS the same as the CLASSIC MRSVHC12AS?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the TGM MRSVHT12AS?
ENERGY STAR lists 3 certified combinations for this outdoor unit. The highest-rated ones use MC4VHT12S, MFCHT12S.
What refrigerant does the TGM MRSVHT12AS use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $309/yrYou save $292/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump TGM MRSVHT12AS
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$309
Current system, per year
$601
You save per year
$292
Payback
15.4 years
Net after 10 years
-$1,577

Cooling $178Heating $130Electricity used: 1,930 kWhSaved vs. a minimum-efficiency heat pump: $153

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 12,000 BTU models

See all 394 12,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 6, 2026. How we use the data.