5-ton central heat pump · W Series
WeatherKing WP15AY60AJ2N
Below average cooling and heating efficiency for a 5-ton central heat pump, but not rated for cold climates.
Ranks #97 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,914 a year to run in a mixed climate like Atlanta.
- SEER2
- 15.2 Cooling efficiency over a seasonBelow average · beats 6%
- HSPF2
- 7.8 Heating efficiency over a seasonBelow average · beats 5%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- - Not reported by the maker
A good fit if…
- You want a choice of indoor units - 35 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
Details
Specifications
| General | |
|---|---|
| Brand | WeatherKing |
| Also sold as | Rheem, Ruud, Fujitsu |
| Outdoor unit model | WP15AY60AJ2N |
| Series | W Series |
| Type | Central heat pump |
| Nominal size | 5 ton |
| CompressorVariable-speed units run longer at low power | Two-stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | August 6, 2024 |
| Last certified | December 11, 2024 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 15.2 (range 15.2) |
| EER2Efficiency at 95°F outdoors | 11.7 |
| Cooling capacity | 55,500-57,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8 |
| Capacity at 47°F | 55,000-56,000 BTU/h |
| Capacity at 17°F | 35,400-55,000 BTU/h |
| Capacity at 5°F | - |
| COP at 5°F2.0 = twice as efficient as a space heater | - |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FHRNTT6024S*YTNA at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| FHRNTT6024S*YTNA | - | 15.2 | 11.7 | 7.8 | - | 215415496 |
| WH2TY6024STANN | - | 15.2 | 11.7 | 7.8 | - | 215415471 |
| RH2TY6024STANN | - | 15.2 | 11.7 | 7.8 | - | 215415483 |
| RH2TY6024STANN | - | 15.2 | 11.7 | 7.8 | - | 215415484 |
| TCFY6021STAAM | W801W1005A21UHS | 15.2 | 11.7 | 7.8 | - | 215657521 |
| RCFY6021STAAM | R801V1005A21UHN | 15.2 | 11.7 | 7.8 | - | 215657522 |
| RCFY6021STAAM | W801W1005A21UHS | 15.2 | 11.7 | 7.8 | - | 215657526 |
| TCFY6021STAAM | W801W1005A21UHN | 15.2 | 11.7 | 7.8 | - | 215657531 |
| RCFY6021STAAM | W801W1005A21UHN | 15.2 | 11.7 | 7.8 | - | 215657544 |
| RCFY6021STAAM | R801V1005A21UHS | 15.2 | 11.7 | 7.8 | - | 215657550 |
| RCFY6021STAAM | R801V1005A21UHN | 15.2 | 11.7 | 7.8 | - | 215657558 |
| RCFY6021STAAM | R801V1005A21UHS | 15.2 | 11.7 | 7.8 | - | 215657567 |
| TCFY6021STAAM | W802W1005A21UH | 15.2 | 11.7 | 7.8 | - | 215657573 |
| RCFY6021STAAM | R802V1005A21UH | 15.2 | 11.7 | 7.8 | - | 215657578 |
| RCFY6021STAAM | W802W1005A21UH | 15.2 | 11.7 | 7.8 | - | 215657583 |
| RCFY6021STAAM | R802V1005A21UH | 15.2 | 11.7 | 7.8 | - | 215657595 |
| RCFY6024STANM | R801V1255A24UH | 15.2 | 11.7 | 7.8 | - | 215656233 |
| RCFY6024STANM | R802V1005A21UH | 15.2 | 11.7 | 7.8 | - | 215656239 |
| RCFY6024STANM | R801V1255A24UH | 15.2 | 11.7 | 7.8 | - | 215656245 |
| RCFY6024STANM | W801W1255A24UH | 15.2 | 11.7 | 7.8 | - | 215656250 |
| TCFY6024STANM | W801W1005A21UHS | 15.2 | 11.7 | 7.8 | - | 215656255 |
| RCFY6024STANM | R801V1005A21UHN | 15.2 | 11.7 | 7.8 | - | 215656259 |
| RCFY6024STANM | R801V1005A21UHS | 15.2 | 11.7 | 7.8 | - | 215656279 |
| RCFY6024STANM | R802V1255A24UH | 15.2 | 11.7 | 7.8 | - | 215656281 |
| RCFY6024STANM | R802V1005A21UH | 15.2 | 11.7 | 7.8 | - | 215656286 |
| TCFY6024STANM | W801W1255A24UH | 15.2 | 11.7 | 7.8 | - | 215656290 |
| RCFY6024STANM | R802V1255A24UH | 15.2 | 11.7 | 7.8 | - | 215656292 |
| TCFY6024STANM | W801W1005A21UHN | 15.2 | 11.7 | 7.8 | - | 215656295 |
| RCFY6024STANM | W802W1005A21UH | 15.2 | 11.7 | 7.8 | - | 215656296 |
| RCFY6024STANM | R801V1005A21UHN | 15.2 | 11.7 | 7.8 | - | 215656299 |
| RCFY6024STANM | W801W1005A21UHN | 15.2 | 11.7 | 7.8 | - | 215656313 |
| RCFY6024STANM | W801W1005A21UHS | 15.2 | 11.7 | 7.8 | - | 215656322 |
| TCFY6024STANM | W802W1005A21UH | 15.2 | 11.7 | 7.8 | - | 215656362 |
| RCFY6024STANM | R801V1005A21UHS | 15.2 | 11.7 | 7.8 | - | 215656363 |
| TCFY6024STANM | W802W1255A24UH | 15.2 | 11.7 | 7.8 | - | 216545077 |
Yearly running cost in 10 large cities
- Phoenix, AZ$2,146/yr
- Miami, FL$1,760/yr
- Houston, TX$1,922/yr
- Atlanta, GA$1,914/yr
- Los Angeles, CA$1,856/yr
- New York, NY$4,536/yr
- Chicago, IL$3,676/yr
- Denver, CO$3,050/yr
- Seattle, WA$1,869/yr
- Minneapolis, MN$3,772/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the WeatherKing WP15AY60AJ2N?
- The WeatherKing WP15AY60AJ2N is rated at up to 15.2 SEER2 and 11.7 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the WeatherKing WP15AY60AJ2N good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 5-ton model.
- How much does the WeatherKing WP15AY60AJ2N cost to run per year?
- At its rated efficiency it costs about $1,760-$4,536 a year in electricity in large U.S. cities, depending on climate and local rates - for example $2,146 in Phoenix and $3,772 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the WeatherKing WP15AY60AJ2N?
- ENERGY STAR lists 35 certified combinations for this outdoor unit. The highest-rated ones use FHRNTT6024S*YTNA, WH2TY6024STANN, RH2TY6024STANN.
- What refrigerant does the WeatherKing WP15AY60AJ2N use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 5 ton models
- WeatherMaker PH5SAN560**AB15.2 SEER2 · 7.8 HSPF2
- Tempstar T5H6S60*K*AAA15.2 SEER2 · 7.8 HSPF2
- Whirlpool WLP14AY60AJ2N15.2 SEER2 · 7.8 HSPF2
- Ruud RP14AY60AJ2N15.2 SEER2 · 7.8 HSPF2
- Whirlpool WLP15AY60AJ2N15.2 SEER2 · 7.8 HSPF2
- RUSSELL SP14AY60AJ2N15.2 SEER2 · 7.8 HSPF2
- Rheem RP15AY60AJ2N15.2 SEER2 · 7.8 HSPF2
- Midea MOVA-61HN10-M152L15.2 SEER2 · 7.8 HSPF2
See all 100 5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of December 11, 2024. How we use the data.