HVAC Rated

48,000 BTU mini-split heat pump · ACIQ Series

1HVAC ACIQ-48ZPL-HP230C

Below average cooling efficiency and very good heating efficiency for a 48,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #117 of 146 48,000 BTU mini-splits for cooling efficiency, and costs about $1,306 a year to run in a mixed climate like Atlanta.

SEER2
18.5 Cooling efficiency over a season
Below average · beats 6%
HSPF2
10.8 Heating efficiency over a season
Very good · beats 71%
EER2
9.4 Cooling efficiency on a 95°F day
Below average · beats 2%
Heat at 5°F
47,500 BTU/h90% of its 47°F output
Average · beats 48%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 47,500 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 71% of mini-splits.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.

Calculate my running cost

Details

Specifications48,000 BTU, R-454B
General
Brand1HVAC
Also sold asACIQ
Outdoor unit modelACIQ-48ZPL-HP230C
SeriesACIQ Series
TypeMini-split heat pump
Nominal size48,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 15, 2024
Last certifiedMarch 4, 2025
Cooling
SEER2Seasonal efficiency, higher is better18.5 (range 16.7-18.5)
EER2Efficiency at 95°F outdoors9.4-10.4
Cooling capacity48,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.1-10.8
Capacity at 47°F52,000 BTU/h
Capacity at 17°F38,500-45,000 BTU/h
Capacity at 5°F47,000-47,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.83-2.00
ENERGY STAR cold climateYes
Heating output as it gets colder90% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ACIQ-48FM-HH-MD at the standard test temperatures, in BTU/h:

Certified matchups6 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
ACIQ-48FM-HH-MD · cold climate18.59.410.147,000216032290
ACIQ-48FM-HH-MD ACIQ · cold climate18.59.410.147,000216032356
ACIQ-48CC-HH-MC · cold climate16.710.410.847,500216032277
ACIQ-48CD-HH-MC · cold climate16.710.410.847,500216032283
ACIQ-48CC-HH-MC ACIQ · cold climate16.710.410.847,500216032343
ACIQ-48CD-HH-MC ACIQ · cold climate16.710.410.847,500216032349
Yearly running cost in 10 large cities$1,217-$3,083

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the 1HVAC ACIQ-48ZPL-HP230C?
The 1HVAC ACIQ-48ZPL-HP230C is rated at up to 18.5 SEER2 and 9.4 EER2 for cooling and up to 10.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 6 certified matchups SEER2 ranges from 16.7-18.5.
Is the 1HVAC ACIQ-48ZPL-HP230C good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 47,500 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the 1HVAC ACIQ-48ZPL-HP230C cost to run per year?
At its rated efficiency it costs about $1,217-$3,083 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,476 in Phoenix and $2,558 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the 1HVAC ACIQ-48ZPL-HP230C?
ENERGY STAR lists 6 certified combinations for this outdoor unit. The highest-rated ones use ACIQ-48FM-HH-MD, ACIQ ACIQ-48FM-HH-MD, ACIQ-48CC-HH-MC.
What refrigerant does the 1HVAC ACIQ-48ZPL-HP230C use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,453/yrYou save $1,088/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump 1HVAC ACIQ-48ZPL-HP230C
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,453
Current system, per year
$2,540
You save per year
$1,088
Payback
16.5 years
Net after 10 years
-$7,121

Cooling $913Heating $539Electricity used: 9,078 kWhSaved vs. a minimum-efficiency heat pump: $506

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 48,000 BTU models

See all 146 48,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 4, 2025. How we use the data.