2.5-ton central heat pump · ACIQ series
ACIQ ACIQ-30-HPB
Very good cooling and heating efficiency for a 2.5-ton central heat pump, and certified for cold climates.
Ranks #33 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $887 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.2 Cooling efficiency over a seasonVery good · beats 73%
- HSPF2
- 9.7 Heating efficiency over a seasonVery good · beats 77%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 27,000 BTU/h87% of its 47°F outputBelow average · beats 12%
A good fit if…
- You want low cooling bills - its SEER2 beats 73% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 27,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 77% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | ACIQ |
| Also sold as | 1HVAC, DIYCOOL, PolarWave, STEALTH |
| Outdoor unit model | ACIQ-30-HPB |
| Series | ACIQ series |
| Type | Central heat pump |
| Nominal size | 2.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | October 1, 2022 |
| Last certified | June 9, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.2 (range 15.2-18.2) |
| EER2Efficiency at 95°F outdoors | 10.0-11.7 |
| Cooling capacity | 28,000-30,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.5-9.7 |
| Capacity at 47°F | 30,000-33,000 BTU/h |
| Capacity at 17°F | 19,600-22,600 BTU/h |
| Capacity at 5°F | 22,600-27,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-1.85 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ACIQ-30W-P at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| ACIQ-30W-P · cold climate | 18.2 | 11.7 | 8.8 | 26,000 | 213433254 |
| ACIQ-30W-P · cold climate | 18.2 | 11.7 | 8.8 | 26,000 | 213433273 |
| ACIQ-30W-P · cold climate | 18.2 | 11.7 | 8.8 | 26,000 | 213433292 |
| ACIQ-30W-P · cold climate | 18.2 | 11.7 | 8.8 | 26,000 | 213433311 |
| ACIQ-30W-P · cold climate | 18.2 | 11.7 | 8.8 | 26,000 | 213433235 |
| ACIQ-30W-WM · cold climate | 16.9 | 10.0 | 9.0 | 25,000 | 213433231 |
| ACIQ-30W-WM · cold climate | 16.9 | 10.0 | 9.0 | 25,000 | 213433250 |
| ACIQ-30W-WM · cold climate | 16.9 | 10.0 | 9.0 | 25,000 | 213433269 |
| ACIQ-30W-WM · cold climate | 16.9 | 10.0 | 9.0 | 25,000 | 213433288 |
| ACIQ-30W-WM · cold climate | 16.9 | 10.0 | 9.0 | 25,000 | 213433307 |
| ACIQ-30-AHB · cold climate | 16.2 | 10.0 | 8.9 | 24,000 | 215570365 |
| ACIQ-30-AHB · cold climate | 16.2 | 10.0 | 8.9 | 24,000 | 215570366 |
| ACIQ-30-AHB · cold climate | 16.2 | 10.0 | 8.9 | 24,000 | 215570367 |
| ACIQ-30-AHB · cold climate | 16.2 | 10.0 | 8.9 | 24,000 | 215570368 |
| ACIQ-30-AHB · cold climate | 16.2 | 10.0 | 8.9 | 24,000 | 215570369 |
| ACIQ-30-ACL · cold climate | 15.5 | 10.5 | 9.7 | 27,000 | 212394324 |
| ACIQ-30-ACL · cold climate | 15.5 | 10.5 | 9.7 | 27,000 | 212394313 |
| ACIQ-30-ACL · cold climate | 15.5 | 10.5 | 9.7 | 27,000 | 212394335 |
| ACIQ-30-ACL · cold climate | 15.5 | 10.5 | 9.7 | 27,000 | 212394346 |
| ACIQ-30-ACL · cold climate | 15.5 | 10.5 | 9.7 | 27,000 | 212394357 |
| ACIQ-36-ACL · cold climate | 15.5 | 10.5 | 9.7 | 27,000 | 213492124 |
| ACIQ-36-ACL · cold climate | 15.5 | 10.5 | 9.7 | 27,000 | 213492148 |
| ACIQ-36-ACL · cold climate | 15.5 | 10.5 | 9.7 | 27,000 | 213492158 |
| ACIQ-36-ACL · cold climate | 15.5 | 10.5 | 9.7 | 27,000 | 213492170 |
| ACIQ-36-ACL · cold climate | 15.5 | 10.5 | 9.7 | 27,000 | 213492136 |
| ACIQ-36-ACL-17 · cold climate | 15.2 | 10.0 | 8.5 | 22,600 | 213492126 |
| ACIQ-36-ACL-17 · cold climate | 15.2 | 10.0 | 8.5 | 22,600 | 213492138 |
| ACIQ-36-ACL-17 · cold climate | 15.2 | 10.0 | 8.5 | 22,600 | 213492149 |
| ACIQ-36-ACL-17 · cold climate | 15.2 | 10.0 | 8.5 | 22,600 | 213492159 |
| ACIQ-36-ACL-17 · cold climate | 15.2 | 10.0 | 8.5 | 22,600 | 213492171 |
Yearly running cost in 10 large cities
- Phoenix, AZ$964/yr
- Miami, FL$776/yr
- Houston, TX$865/yr
- Atlanta, GA$887/yr
- Los Angeles, CA$866/yr
- New York, NY$2,134/yr
- Chicago, IL$1,735/yr
- Denver, CO$1,445/yr
- Seattle, WA$890/yr
- Minneapolis, MN$1,789/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the ACIQ ACIQ-30-HPB?
- The ACIQ ACIQ-30-HPB is rated at up to 18.2 SEER2 and 11.7 EER2 for cooling and up to 9.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 30 certified matchups SEER2 ranges from 15.2-18.2.
- Is the ACIQ ACIQ-30-HPB good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 27,000 BTU/h at 5°F with a COP of 1.85, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the ACIQ ACIQ-30-HPB cost to run per year?
- At its rated efficiency it costs about $776-$2,134 a year in electricity in large U.S. cities, depending on climate and local rates - for example $964 in Phoenix and $1,789 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the ACIQ ACIQ-30-HPB?
- ENERGY STAR lists 30 certified combinations for this outdoor unit. The highest-rated ones use ACIQ-30W-P, ACIQ-30W-WM, ACIQ-30-AHB.
- What refrigerant does the ACIQ ACIQ-30-HPB use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2.5 ton models
- TOSOT TUD36-24W2/NHE-D(U) · cold climate18.2 SEER2 · 10.0 HSPF2
- Innovair SHV30H2R20 · cold climate18.2 SEER2 · 9.7 HSPF2
- GREE GUD36W2/NHE-D(U) · cold climate18.2 SEER2 · 10.0 HSPF2
- MDV MOD30U-30HFN1-MR0(X) · cold climate18.2 SEER2 · 9.7 HSPF2
- GREE FXU36HP230V1R32AO · cold climate18.2 SEER2 · 10.0 HSPF2
- Multi MFG HHS-30HD-A · cold climate18.2 SEER2 · 9.0 HSPF2
- AireForce UXH24-36MSK3IH · cold climate18.2 SEER2 · 10.0 HSPF2
- AC Pro AOD30U-30HFN1-MR0(X) · cold climate18.2 SEER2 · 8.8 HSPF2
See all 199 2.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 9, 2026. How we use the data.