HVAC Rated

4-ton central heat pump · 7HP14F Series

ALLIED 7HP14F48P-**A

Below average cooling and heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #279 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,547 a year to run in a mixed climate like Atlanta.

SEER2
15.5 Cooling efficiency over a season
Below average · beats 15%
HSPF2
8.2 Heating efficiency over a season
Below average · beats 28%
EER2
12.8 Cooling efficiency on a 95°F day
Very good · beats 85%
Heat at 5°F
24,600 BTU/h51% of its 47°F output
Very good · beats 76%

A good fit if…

  • You want a choice of indoor units - 68 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandALLIED
Also sold asDucane, Concord, Breeze33
Outdoor unit model7HP14F48P-**A
Series7HP14F Series
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 30, 2023
Last certifiedOctober 27, 2025
Cooling
SEER2Seasonal efficiency, higher is better15.5 (range 15.2-15.5)
EER2Efficiency at 95°F outdoors12.4-13.0
Cooling capacity48,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.2
Capacity at 47°F46,000-48,000 BTU/h
Capacity at 17°F29,600-30,600 BTU/h
Capacity at 5°F23,400-24,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.12-2.20
ENERGY STAR cold climateNo
Heating output as it gets colder51% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7AH2AV48PXC at the standard test temperatures, in BTU/h:

Certified matchups68 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 68 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
7AH2AV48PXC-15.512.88.224,200215746994
7AH2AV60PXC-15.513.08.223,400215746995
7AH2AV48PXC-15.512.88.224,200215747044
7AH2AV60PXC-15.513.08.223,400215747045
7AH2AV48PXC-15.512.88.224,200215746944
7AH2AV60PXC-15.513.08.223,400215746945
7AH2AV48PXC-15.512.88.224,200215792759
7AH2AV60PXC-15.513.08.223,400215792760
7AH2AE48PX--15.212.48.224,600215747042
7AH2AE48PX--15.212.48.224,600215746942
7AH2AE48PX--15.212.48.224,600215746992
7AH2AE48PX--15.212.48.224,600215792757
7E[C,U]60CX-**+TDR80G2UH110CE20*15.212.88.124,200215746974
7E[C,U]60CX-**+TDR80G2UH110CE20L*15.212.88.124,200215746975
7E[C,U]60CX-**+TDR80G2UH110CE20L*15.212.88.124,200215747075
7E[C,U]60CX-**+TDR80G2UH110CE20*15.212.88.124,200215747024
7E[C,U]60CX-**+TDR80G2UH110CE20L*15.212.88.124,200215747025
7E[C,U]60CX-**+TDR80G2UH110CE20*15.212.88.124,200215747074
7E[C,U]60CX-**+TDR80G2UH110CE20*15.212.88.124,200215792789
7E[C,U]60CX-**+TDR80G2UH110CE20L*15.212.88.124,200215792790
7E[C,U]60CX-**+TDR80G1UH090CE20*15.212.88.024,200215746977
7E[C,U]60CX-**+TDR80G1UH110CE20*15.212.88.024,000215746978
7E[C,U]60CX-**+TDR92G1UH090CE16*15.212.88.024,200215746980
7E[C,U]60CX-**+TDR92G1UH110CE16*15.212.88.023,800215746981
7E[C,U]60CX-**+TDR80G1UH090CE20*15.212.88.024,200215747027
7E[C,U]60CX-**+TDR80G1UH110CE20*15.212.88.024,000215747028
7E[C,U]60CX-**+TDR80G1UH110CE20L*15.212.88.024,000215747029
7E[C,U]60CX-**+TDR92G1UH090CE16*15.212.88.024,200215747030
7E[C,U]60CX-**+TDR92G1UH110CE16*15.212.88.023,800215747031
7E[C,U]60CX-**+TDR92G1UH110CE20*15.212.88.024,000215747032
7E[C,U]60CX-**+TDR80G2UH110CE16*15.213.08.023,800215747073
7E[C,U]60CX-**+TDR92G1UH110CE20*15.212.88.024,000215747082
7E[C,U]60CX-**+TDR96G1UH090CE16*15.212.88.024,200215747088
7E[C,U]60CX-**+TDR97G2UH090CE16*15.212.88.024,200215747037
7E[C,U]60CX-**+TDR80G2UH110CE16*15.213.08.023,800215746973
7E[C,U]60CX-**+TDR80G1UH110CE20*15.212.88.024,000215747078
7E[C,U]60CX-**+TDR80G1UH110CE20L*15.212.88.024,000215747079
7E[C,U]60CX-**+TDR92G1UH110CE16*15.212.88.023,800215747081
7E[C,U]60CX-**+TDR97G2UH090CE16*15.212.88.024,200215746987
7E[C,U]60CX-**+TDR96G1UH090CE16*15.212.88.024,200215746988
7E[C,U]60CX-**+TDR80G2UH110CE16*15.213.08.023,800215747023
7E[C,U]60CX-**+TDR97G2UH090CE16*15.212.88.024,200215747087
7E[C,U]60CX-**+TDR96G1UH090CE16*15.212.88.024,200215747038
7E[C,U]60CX-**+TDR80G1UH090CE20*15.212.88.024,200215747077
7E[C,U]60CX-**+TDR92G1UH090CE16*15.212.88.024,200215747080
7E[C,U]60CX-**+TDR80G1UH110CE20L*15.212.88.024,000215746979
7E[C,U]60CX-**+TDR92G1UH110CE20*15.212.88.024,000215746982
7E[C,U]60CX-**+TDR80G2UH110CE16*15.213.08.023,800215792788
7E[C,U]60CX-**+TDR80G1UH090CE20*15.212.88.024,200215792792
7E[C,U]60CX-**+TDR80G1UH110CE20*15.212.88.024,000215792793
7E[C,U]60CX-**+TDR80G1UH110CE20L*15.212.88.024,000215792794
7E[C,U]60CX-**+TDR92G1UH090CE16*15.212.88.024,200215792795
7E[C,U]60CX-**+TDR92G1UH110CE16*15.212.88.023,800215792796
7E[C,U]60CX-**+TDR92G1UH110CE20*15.212.88.024,000215792797
7E[C,U]60CX-**+TDR97G2UH090CE16*15.212.88.024,200215792802
7E[C,U]60CX-**+TDR96G1UH090CE16*15.212.88.024,200215792803
7E[C,U]60CX-**+TDR80G2UH110CV20*15.212.88.024,000216779531
7E[C,U]60CX-**+TDR80G2UH110CV20*15.212.88.024,000216779538
7E[C,U]60CX-**+TDR80G2UH110CV20*15.212.88.024,000216779545
7E[C,U]60CX-**+TDR80G2UH110CV20*15.212.88.024,000216779524
Yearly running cost in 10 large cities$1,451-$3,641

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the ALLIED 7HP14F48P-**A?
The ALLIED 7HP14F48P-**A is rated at up to 15.5 SEER2 and 12.8 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 68 certified matchups SEER2 ranges from 15.2-15.5.
Is the ALLIED 7HP14F48P-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the ALLIED 7HP14F48P-**A cost to run per year?
At its rated efficiency it costs about $1,451-$3,641 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,756 in Phoenix and $3,017 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the ALLIED 7HP14F48P-**A?
ENERGY STAR lists 68 certified combinations for this outdoor unit. The highest-rated ones use 7AH2AV48PXC, 7AH2AV60PXC, 7AH2AE48PX-.
What refrigerant does the ALLIED 7HP14F48P-**A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,725/yrYou save $725/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump ALLIED 7HP14F48P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,725
Current system, per year
$2,450
You save per year
$725
Payback
24.8 years
Net after 10 years
-$10,747

Cooling $1,090Heating $635Electricity used: 10,782 kWhSaved vs. a minimum-efficiency heat pump: $151

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.