4-ton central heat pump · NS16H Series
GE NS16H48SA5-**A
Below average cooling and heating efficiency for a 4-ton central heat pump, but not rated for cold climates.
Ranks #281 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,557 a year to run in a mixed climate like Atlanta.
- SEER2
- 15.5 Cooling efficiency over a seasonBelow average · beats 15%
- HSPF2
- 8.2 Heating efficiency over a seasonBelow average · beats 28%
- EER2
- 12.8 Cooling efficiency on a 95°F dayVery good · beats 85%
- Heat at 5°F
- 24,200 BTU/h51% of its 47°F outputVery good · beats 76%
A good fit if…
- You want a choice of indoor units - 10 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | GE |
| Outdoor unit model | NS16H48SA5-**A |
| Series | NS16H Series |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 1, 2024 |
| Last certified | April 22, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 15.5 (range 15.2-15.5) |
| EER2Efficiency at 95°F outdoors | 12.8-13.0 |
| Cooling capacity | 48,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.0-8.2 |
| Capacity at 47°F | 46,000-47,500 BTU/h |
| Capacity at 17°F | 29,600-30,200 BTU/h |
| Capacity at 5°F | 23,400-24,200 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.12-2.20 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NAM48V2TA5*- at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| NAM48V2TA5*- | - | 15.5 | 12.8 | 8.2 | 24,200 | 216497709 |
| NAM60V2TA5*- | - | 15.5 | 13.0 | 8.2 | 23,400 | 216497710 |
| NCU[C,U]60CT5*-**+TDR | NF80U110T5C* | 15.2 | 12.8 | 8.1 | 24,200 | 216497736 |
| NCU[C,U]60CT5*-**+TDR | NF80U090S5C* | 15.2 | 12.8 | 8.0 | 24,200 | 216497737 |
| NCU[C,U]60CT5*-**+TDR | NF80U110S5C* | 15.2 | 12.8 | 8.0 | 24,000 | 216497738 |
| NCU[C,U]60CT5*-**+TDR | NF80L110S5C* | 15.2 | 12.8 | 8.0 | 24,000 | 216497739 |
| NCU[C,U]60CT5*-**+TDR | NF96U090S4C* | 15.2 | 12.8 | 8.0 | 24,200 | 216497751 |
| NCU[C,U]60CT5*-**+TDR | NF80X100V5C* | 15.2 | 12.8 | 8.0 | 24,000 | 216497742 |
| NCU[C,U]60CT5*-**+TDR | NF80U110V5C* | 15.2 | 12.8 | 8.0 | 24,000 | 217052208 |
| NCU[C,U]60CT5*-**+TDR | NF97U090T4C* | 15.2 | 12.8 | 8.0 | 24,200 | 218159790 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,761/yr
- Miami, FL$1,452/yr
- Houston, TX$1,577/yr
- Atlanta, GA$1,557/yr
- Los Angeles, CA$1,506/yr
- New York, NY$3,672/yr
- Chicago, IL$2,972/yr
- Denver, CO$2,464/yr
- Seattle, WA$1,508/yr
- Minneapolis, MN$3,046/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the GE NS16H48SA5-**A?
- The GE NS16H48SA5-**A is rated at up to 15.5 SEER2 and 12.8 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 10 certified matchups SEER2 ranges from 15.2-15.5.
- Is the GE NS16H48SA5-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
- How much does the GE NS16H48SA5-**A cost to run per year?
- At its rated efficiency it costs about $1,452-$3,672 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,761 in Phoenix and $3,046 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the GE NS16H48SA5-**A?
- ENERGY STAR lists 10 certified combinations for this outdoor unit. The highest-rated ones use NAM48V2TA5*-, NAM60V2TA5*-, NCU[C,U]60CT5*-**+TDR.
- What refrigerant does the GE NS16H48SA5-**A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- Armstrong Air A7HP14F48P-**A15.5 SEER2 · 8.2 HSPF2
- Lennox EL16KP1-048-230A15.5 SEER2 · 8.2 HSPF2
- ALLIED 7HP14F48P-**A15.5 SEER2 · 8.2 HSPF2
- Bryant 37MURAQ48AA3+KSAIC0701230 · cold climate15.5 SEER2 · 8.1 HSPF2
- Tempstar D5CUHAH48AAK+KSAIC0701230 · cold climate15.5 SEER2 · 8.5 HSPF2
- Tempstar D5CURAH48AAK+KSAIC0701230 · cold climate15.5 SEER2 · 8.1 HSPF2
- Bryant 37MUHAQ48AA3+KSAIC0701230 · cold climate15.5 SEER2 · 8.5 HSPF2
- Bryant 235SAN048**AA15.5 SEER2 · 7.8 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of April 22, 2026. How we use the data.