1.5-ton central heat pump · 4SHP17LE SERIES
Armstrong Air 4SHP17LE118P-**A
Average cooling efficiency and below average heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.
Ranks #75 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $549 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.8 Cooling efficiency over a seasonAverage · beats 45%
- HSPF2
- 8.5 Heating efficiency over a seasonBelow average · beats 38%
- EER2
- 14.0 Cooling efficiency on a 95°F dayExcellent · beats 98%
- Heat at 5°F
- 9,700 BTU/h44% of its 47°F outputVery good · beats 70%
A good fit if…
- You want a choice of indoor units - 662 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Armstrong Air |
| Also sold as | AIREASE |
| Outdoor unit model | 4SHP17LE118P-**A |
| Series | 4SHP17LE SERIES |
| Type | Central heat pump |
| Nominal size | 1.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 5, 2022 |
| Last certified | May 27, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.8 (range 15.2-16.8) |
| EER2Efficiency at 95°F outdoors | 12.2-14.0 |
| Cooling capacity | 18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.5 |
| Capacity at 47°F | 16,000-18,000 BTU/h |
| Capacity at 17°F | 10,200-12,100 BTU/h |
| Capacity at 5°F | 7,500-9,700 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.90-2.16 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EA(C;U)1P30B+TDR+TXV at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 662 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| EA(C;U)1P30B+TDR+TXV | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 7,800 | 211662782 |
| EA(C;U)1P30B+TDR+TXV | A80US2V090B12 | 16.8 | 14.0 | 8.1 | 8,000 | 211662783 |
| EA(C;U)1P30A+TDR+TXV | A80US2V090B12 | 16.8 | 14.0 | 8.1 | 8,000 | 210329630 |
| EAC4X30B+TDR | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 7,800 | 211662341 |
| EAC4X30B+TDR | A80US2V090B12 | 16.8 | 14.0 | 8.1 | 8,000 | 211662342 |
| EA(C;U)1P30A+TDR+TXV | A80US2V090B12 | 16.8 | 14.0 | 8.1 | 8,000 | 210330240 |
| EAC4X30B+TDR | A80US2V090B12 | 16.8 | 14.0 | 8.1 | 8,000 | 211662860 |
| EAC4X30B+TDR | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 7,800 | 211662859 |
| EA(C;U)1P30A+TDR+TXV | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 7,800 | 210330239 |
| EA(C;U)1P30A+TDR+TXV | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 7,800 | 210329629 |
| EA(C;U)1P30B+TDR+TXV | A80US2V090B12 | 16.8 | 14.0 | 8.1 | 8,000 | 211662265 |
| EA(C;U)1P30B+TDR+TXV | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 7,800 | 211662264 |
| EAH1P24B*+TDR+TXV | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 8,400 | 211734623 |
| EAH1P24B*+TDR+TXV | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 8,400 | 211734624 |
| EAH1P24B*+TDR+TXV | A80US2V090B12 | 16.8 | 14.0 | 8.1 | 8,400 | 211734625 |
| EAH1P24B*+TDR+TXV | A80US2V090B12 | 16.8 | 14.0 | 8.1 | 8,400 | 211734627 |
| EAH1P30B*+TDR+TXV | A97US2V060B12X | 16.8 | 14.0 | 8.1 | 7,800 | 211734872 |
| EAH1P30B*+TDR+TXV | A97US2V060B12X | 16.8 | 14.0 | 8.1 | 7,800 | 211734874 |
| EAH1P24A*+TDR+TXV | A80US2V060A12X | 16.8 | 14.0 | 8.1 | 8,200 | 211734382 |
| EAH1P24A*+TDR+TXV | A80US2V060A12X | 16.8 | 14.0 | 8.1 | 8,200 | 211734383 |
| EAH1P30B*+TDR+TXV | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 8,000 | 211734849 |
| EAH1P30B*+TDR+TXV | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 8,000 | 211734847 |
| 7EH24BX-0*+TDR | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 8,400 | 214713673 |
| 7EH24BX-0*+TDR | A80US2V090B12 | 16.8 | 14.0 | 8.1 | 8,400 | 214713674 |
| 7EC30BX-0*+TDR | A80US2V090B12 | 16.8 | 14.0 | 8.1 | 8,000 | 214713775 |
| 7EC30BX-0*+TDR | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 7,800 | 214713774 |
| 7EH24AX-0*+TDR | A80US2V060A12X | 16.8 | 14.0 | 8.1 | 8,200 | 214713655 |
| 7EH30BX-0*+TDR | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 8,000 | 214713695 |
| 7EH30BX-0*+TDR | A97US2V060B12X | 16.8 | 14.0 | 8.1 | 7,800 | 214713699 |
| 7EH30BX-0*+TDR | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 8,000 | 214715188 |
| 7EH24AX-0*+TDR | A80US2V060A12X | 16.8 | 14.0 | 8.1 | 8,200 | 214715148 |
| 7EC30BX-0*+TDR | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 7,800 | 214715267 |
| 7EC30BX-0*+TDR | A80US2V090B12 | 16.8 | 14.0 | 8.1 | 8,000 | 214715268 |
| 7EH24BX-0*+TDR | A80US2V080B16X | 16.8 | 14.0 | 8.1 | 8,400 | 214715166 |
| 7EH24BX-0*+TDR | A80US2V090B12 | 16.8 | 14.0 | 8.1 | 8,400 | 214715167 |
| 7EH30BX-0*+TDR | A97US2V060B12X | 16.8 | 14.0 | 8.1 | 7,800 | 214715192 |
| EA(C;U)1P30A+TDR+TXV | A97US2V040B12X | 16.8 | 13.5 | 8.0 | 7,800 | 210329624 |
| EA(C;U)1P30A+TDR+TXV | A80UH2E090B12 | 16.8 | 14.0 | 8.0 | 7,600 | 210329619 |
| EA(C;U)1P30A+TDR+TXV | A80UH2E070A12 | 16.8 | 13.5 | 8.0 | 7,600 | 210330217 |
| EA(C;U)1P30B+TDR+TXV | A97USMV070B12 | 16.8 | 13.5 | 8.0 | 7,800 | 211662269 |
| EAC4X30A+TDR | A80US2V060A12X | 16.8 | 14.0 | 8.0 | 7,900 | 211662324 |
| EAC4X30B+TDR | A80UH2E090B12 | 16.8 | 14.0 | 8.0 | 7,600 | 211662327 |
| EA(C;U)1P30A+TDR+TXV | A80UH2E090B12 | 16.8 | 14.0 | 8.0 | 7,600 | 210330229 |
| EAC4X30A+TDR | A80UH2E070A12 | 16.8 | 13.5 | 8.0 | 7,600 | 211662839 |
| EAC4X30A+TDR | A80US2V060A12X | 16.8 | 14.0 | 8.0 | 7,900 | 211662842 |
| EAC4X30B+TDR | A80UH2E090B12 | 16.8 | 14.0 | 8.0 | 7,600 | 211662845 |
| EAC4X30B+TDR | A97USMV070B12 | 16.8 | 13.5 | 8.0 | 7,800 | 211662346 |
| EA(C;U)1P30B+TDR+TXV | A80UH2E090B12 | 16.8 | 14.0 | 8.0 | 7,600 | 211662768 |
| EA(C;U)1P30A+TDR+TXV | A80UH2E070A12 | 16.8 | 13.5 | 8.0 | 7,600 | 210329607 |
| EA(C;U)1P30A+TDR+TXV | A80US2V060A12X | 16.8 | 14.0 | 8.0 | 7,900 | 210330219 |
| EA(C;U)1P30B+TDR+TXV | A97US2V040B12X | 16.8 | 13.5 | 8.0 | 7,800 | 211662785 |
| EAC4X30B+TDR | A97US2V040B12X | 16.8 | 13.5 | 8.0 | 7,800 | 211662344 |
| EAC4X30B+TDR | A97US2V060B12X | 16.8 | 13.5 | 8.0 | 7,800 | 211662345 |
| EAC4X30A+TDR | A80UH2E070A12 | 16.8 | 13.5 | 8.0 | 7,600 | 211662321 |
| EA(C;U)1P30A+TDR+TXV | A97US2V040B12X | 16.8 | 13.5 | 8.0 | 7,800 | 210330234 |
| EA(C;U)1P30A+TDR+TXV | A80US2V060A12X | 16.8 | 14.0 | 8.0 | 7,900 | 210329609 |
| EA(C;U)1P30A+TDR+TXV | A97USMV070B12 | 16.8 | 13.5 | 8.0 | 7,800 | 210330236 |
| EAC4X30B+TDR | A97US2V040B12X | 16.8 | 13.5 | 8.0 | 7,800 | 211662862 |
| EA(C;U)1P30A+TDR+TXV | A97USMV070B12 | 16.8 | 13.5 | 8.0 | 7,800 | 210329626 |
| EA(C;U)1P30B+TDR+TXV | A97USMV070B12 | 16.8 | 13.5 | 8.0 | 7,800 | 211662787 |
Yearly running cost in 10 large cities
- Phoenix, AZ$614/yr
- Miami, FL$503/yr
- Houston, TX$550/yr
- Atlanta, GA$549/yr
- Los Angeles, CA$533/yr
- New York, NY$1,303/yr
- Chicago, IL$1,056/yr
- Denver, CO$877/yr
- Seattle, WA$538/yr
- Minneapolis, MN$1,084/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Armstrong Air 4SHP17LE118P-**A?
- The Armstrong Air 4SHP17LE118P-**A is rated at up to 16.8 SEER2 and 14.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 662 certified matchups SEER2 ranges from 15.2-16.8.
- Is the Armstrong Air 4SHP17LE118P-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
- How much does the Armstrong Air 4SHP17LE118P-**A cost to run per year?
- At its rated efficiency it costs about $503-$1,303 a year in electricity in large U.S. cities, depending on climate and local rates - for example $614 in Phoenix and $1,084 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Armstrong Air 4SHP17LE118P-**A?
- ENERGY STAR lists 662 certified combinations for this outdoor unit. The highest-rated ones use EA(C;U)1P30B+TDR+TXV, EA(C;U)1P30A+TDR+TXV, EAC4X30B+TDR.
- What refrigerant does the Armstrong Air 4SHP17LE118P-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 1.5 ton models
- Jetson HP-18ODU-001 · cold climate17.0 SEER2 · 9.3 HSPF2
- Comfort-Aire HRG1518S1R-**A16.8 SEER2 · 8.5 HSPF2
- TCL H18TDHXPC · cold climate17.0 SEER2 · 9.5 HSPF2
- Ducane 4HP17L18P-**A16.8 SEER2 · 8.5 HSPF2
- AC Pro AOX430U-18HFN1-M · cold climate17.0 SEER2 · 9.5 HSPF2
- GE NS17H18SA4-**A16.8 SEER2 · 8.5 HSPF2
- Lennox ML15KSPV-018-230A · cold climate17.2 SEER2 · 8.8 HSPF2
- Lennox EL17XP1-018-230A16.8 SEER2 · 8.5 HSPF2
See all 170 1.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 27, 2026. How we use the data.