HVAC Rated

2-ton central heat pump · A7CP21V SERIES

Armstrong Air A7CP21V24P-**A

Excellent cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #7 of 331 2 ton central heat pumps for cooling efficiency, and costs about $618 a year to run in a mixed climate like Atlanta.

SEER2
21.0 Cooling efficiency over a season
Excellent · beats 97%
HSPF2
10.2 Heating efficiency over a season
Excellent · beats 91%
EER2
13.5 Cooling efficiency on a 95°F day
Excellent · beats 95%
Heat at 5°F
18,600 BTU/h75% of its 47°F output
Very good · beats 88%

A good fit if…

  • You want low cooling bills - its SEER2 beats 97% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 18,600 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 91% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandArmstrong Air
Also sold asAIREASE, AC Pro
Outdoor unit modelA7CP21V24P-**A
SeriesA7CP21V SERIES
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceMarch 7, 2025
Last certifiedSeptember 30, 2026
Cooling
SEER2Seasonal efficiency, higher is better21.0 (range 15.2-21.0)
EER2Efficiency at 95°F outdoors11.2-13.5
Cooling capacity21,600-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-10.2
Capacity at 47°F23,600-27,400 BTU/h
Capacity at 17°F18,700-22,400 BTU/h
Capacity at 5°F13,900-18,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.70-2.30
ENERGY STAR cold climateYes
Heating output as it gets colder75% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7EH24BX-**+TDR at the standard test temperatures, in BTU/h:

Certified matchups391 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 391 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
7EH24BX-**+TDR · cold climateA97UH1E030B12*21.013.58.218,100218788059
7EH24BX-**+TDR · cold climateA97UH1E030B12*21.013.58.218,100218788051
7AH2AV30PXC · cold climate-20.512.010.017,900217117577
7AH2AV30PXC · cold climate-20.512.010.017,900217117581
7AH2AV24PXC · cold climate-20.513.010.018,600217120427
7AH2AV24PXC · cold climate-20.513.010.018,600217120501
7AH2AV30PXC · cold climate-20.512.010.017,900217465738
7AH2AV24PXC · cold climate-20.513.010.018,600217465740
7AH2AE30PX- · cold climate-20.513.09.817,900217122218
7AH2AE30PX- · cold climate-20.513.09.817,900217122117
7AH2AE24PX- · cold climate-20.513.09.818,600217122118
7AH2AE24PX- · cold climate-20.513.09.818,600217122219
7AH2AE30PX- · cold climate-20.513.09.817,900217465952
7AH2AE24PX- · cold climate-20.513.09.818,600217465953
7EH30AX-**+TDRA80UH2E045A12*20.512.59.016,700217446235
7EH30AX-**+TDRA80UH2E045A12*20.512.59.016,700217446466
7EH30AX-**+TDRA80UH2E045A12*20.512.59.016,700217466040
7AH1AV30PX- · cold climate-20.513.08.517,800217122217
7AH1AV30PX- · cold climate-20.513.08.517,800217122116
7AH1AV30PX- · cold climate-20.513.08.517,800217465951
7E[C,U]30BX-**+TDR · cold climateA97US2V040B12X*20.012.810.017,700217120435
7E[C,U]30BX-**+TDR · cold climateA97US2V040B12X*20.012.810.017,700217120509
7E[C,U]30BX-**+TDR · cold climateA97US2V040B12X*20.012.810.017,700217465748
7E[C,U]30AX-**+TDR · cold climateA80UH1E060A12X*20.012.69.817,600217122050
7E[C,U]30AX-**+TDR · cold climateA80UH1E040A12X*20.012.69.817,600217122049
7E[C,U]30AX-**+TDR · cold climateA80UH1E060A12X*20.012.69.817,600217122151
7E[C,U]30AX-**+TDR · cold climateA80UH1E040A12X*20.012.69.817,600217122150
7AH1AV24PX--20.013.09.817,300217446196
7AH1AV24PX--20.013.09.817,300217446427
7E[C,U]30AX-**+TDR · cold climateA80UH1E040A12X*20.012.69.817,600217465884
7E[C,U]30AX-**+TDR · cold climateA80UH1E060A12X*20.012.69.817,600217465885
7AH1AV24PX--20.013.09.817,300217466001
7EH30BX-**+TDR · cold climateA97US2V060B12X*20.013.09.417,100217446223
7EH30BX-**+TDR · cold climateA80US2V090B12*20.013.09.417,000217446451
7EH30BX-**+TDR · cold climateA98USMV070B12S*20.013.09.417,000217446224
7EH30BX-**+TDR · cold climateA80US2V090B12*20.013.09.417,000217446220
7EH30BX-**+TDR · cold climateA97US2V040B12X*20.013.09.417,100217446222
7EH30BX-**+TDRA97US2V070B12S*20.013.09.417,000217446229
7EH30BX-**+TDR · cold climateA97US2V040B12X*20.013.09.417,100217446453
7EH30BX-**+TDR · cold climateA97US2V060B12X*20.013.09.417,100217446454
7EH30BX-**+TDR · cold climateA98USMV070B12S*20.013.09.417,000217446455
7EH30BX-**+TDRA97US2V070B12S*20.013.09.417,000217446460
7EH30BX-**+TDR · cold climateA80US2V090B12*20.013.09.417,000217466025
7EH30BX-**+TDR · cold climateA97US2V040B12X*20.013.09.417,100217466027
7EH30BX-**+TDR · cold climateA97US2V060B12X*20.013.09.417,100217466028
7EH30BX-**+TDR · cold climateA98USMV070B12S*20.013.09.417,000217466029
7EH30BX-**+TDRA97US2V070B12S*20.013.09.417,000217466034
7EH30AX-**+TDRA80US2V060A12X*20.012.59.017,100217446238
7EH30AX-**+TDRA80US2V060A12X*20.012.59.017,100217446469
7EH30AX-**+TDRA80US2V060A12X*20.012.59.017,100217466043
7ED30/36BX-**+TDRA80DS2V090B16*20.012.58.516,300217446204
7ED30/36BX-**+TDRA97DS2V045B12S*20.012.58.516,200217446205
7ED30/36BX-**+TDRA80DS2V090B16*20.012.58.516,300217446435
7ED30/36BX-**+TDRA97DS2V045B12S*20.012.58.516,200217446436
7ED30/36BX-**+TDRA97DSMV070B12S*20.012.58.516,300217446437
7ED30/36BX-**+TDRA97DSMV070B12S*20.012.58.516,300217446206
7EH24AX-**+TDR · cold climateA80UH1E040A12X*20.013.08.517,500217446230
7EH24AX-**+TDR · cold climateA80UH1E060A12X*20.013.08.517,500217446231
7EH24AX-**+TDR · cold climateA80UH2E070A12*20.013.08.517,600217446232
7EH24AX-**+TDR · cold climateA80UH1E040A12X*20.013.08.517,500217446461
Yearly running cost in 10 large cities$525-$1,500

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Armstrong Air A7CP21V24P-**A?
The Armstrong Air A7CP21V24P-**A is rated at up to 21.0 SEER2 and 13.5 EER2 for cooling and up to 10.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 391 certified matchups SEER2 ranges from 15.2-21.0.
Is the Armstrong Air A7CP21V24P-**A good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 18,600 BTU/h at 5°F with a COP of 2.30, so it is still 2.3 times as efficient as electric resistance heat at that temperature.
How much does the Armstrong Air A7CP21V24P-**A cost to run per year?
At its rated efficiency it costs about $525-$1,500 a year in electricity in large U.S. cities, depending on climate and local rates - for example $661 in Phoenix and $1,263 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Armstrong Air A7CP21V24P-**A?
ENERGY STAR lists 391 certified combinations for this outdoor unit. The highest-rated ones use 7EH24BX-**+TDR, 7AH2AV30PXC, 7AH2AV24PXC.
What refrigerant does the Armstrong Air A7CP21V24P-**A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $662/yrYou save $564/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Armstrong Air A7CP21V24P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$662
Current system, per year
$1,226
You save per year
$564
Payback
16.0 years
Net after 10 years
-$3,361

Cooling $392Heating $270Electricity used: 4,140 kWhSaved vs. a minimum-efficiency heat pump: $281

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.