1.5-ton central heat pump · BMS Series
Blueridge BMSAH18HHC
Very good cooling efficiency and excellent heating efficiency for a 1.5-ton central heat pump, and certified for cold climates.
Ranks #26 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $497 a year to run in a mixed climate like Atlanta.
- SEER2
- 19.0 Cooling efficiency over a seasonVery good · beats 85%
- HSPF2
- 10.1 Heating efficiency over a seasonExcellent · beats 90%
- EER2
- 12.5 Cooling efficiency on a 95°F dayVery good · beats 80%
- Heat at 5°F
- 18,600 BTU/h103% of its 47°F outputAverage · beats 65%
A good fit if…
- You want low cooling bills - its SEER2 beats 85% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 18,600 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 90% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Blueridge |
| Also sold as | Kaden |
| Outdoor unit model | BMSAH18HHC |
| Series | BMS Series |
| Type | Central heat pump |
| Nominal size | 1.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 1, 2024 |
| Last certified | March 13, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 19.0 (range 19.0) |
| EER2Efficiency at 95°F outdoors | 12.5 |
| Cooling capacity | 18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.7-10.1 |
| Capacity at 47°F | 18,000-19,000 BTU/h |
| Capacity at 17°F | 14,700-15,000 BTU/h |
| Capacity at 5°F | 18,000-18,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.12 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BMS3AH18I at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| BMS3AH18I · cold climate | 19.0 | 12.5 | 10.1 | 18,600 | 215853875 |
| BMS2AH18I · cold climate | 19.0 | 12.5 | 9.7 | 18,000 | 215853869 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the Blueridge BMSAH18HHC: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Kaden KOB-HH-UUX18HP-2AAMA
Yearly running cost in 10 large cities
- Phoenix, AZ$549/yr
- Miami, FL$445/yr
- Houston, TX$492/yr
- Atlanta, GA$497/yr
- Los Angeles, CA$484/yr
- New York, NY$1,189/yr
- Chicago, IL$965/yr
- Denver, CO$802/yr
- Seattle, WA$493/yr
- Minneapolis, MN$993/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Blueridge BMSAH18HHC?
- The Blueridge BMSAH18HHC is rated at up to 19.0 SEER2 and 12.5 EER2 for cooling and up to 10.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Blueridge BMSAH18HHC good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 18,600 BTU/h at 5°F with a COP of 2.12, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
- How much does the Blueridge BMSAH18HHC cost to run per year?
- At its rated efficiency it costs about $445-$1,189 a year in electricity in large U.S. cities, depending on climate and local rates - for example $549 in Phoenix and $993 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Blueridge BMSAH18HHC the same as the Kaden KOB-HH-UUX18HP-2AAMA?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the Blueridge BMSAH18HHC?
- ENERGY STAR lists 2 certified combinations for this outdoor unit. The highest-rated ones use BMS3AH18I, BMS2AH18I.
- What refrigerant does the Blueridge BMSAH18HHC use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 1.5 ton models
- TRUST AIR CONDITIONERS AA18H/O64P · cold climate19.0 SEER2 · 10.5 HSPF2
- KEEN Home KEENHYDHP18AA · cold climate19.0 SEER2 · 10.5 HSPF2
- DIRECT AIR DIRM4-18MAGICPRO20-OU · cold climate19.0 SEER2 · 10.1 HSPF2
- AproDr AHU3G-18HFN-B · cold climate19.0 SEER2 · 10.5 HSPF2
- ECO-AIR ECUO-18H · cold climate19.0 SEER2 · 10.1 HSPF2
- AC Pro SPHP-Z-V018BB · cold climate19.0 SEER2 · 10.5 HSPF2
- NOVAIR LEA18CEN36-O · cold climate19.0 SEER2 · 10.1 HSPF2
- HAVELLS GHO18H52ACXL05 · cold climate19.2 SEER2 · 9.0 HSPF2
See all 170 1.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 13, 2025. How we use the data.