1.5-ton central heat pump · HSA14 Series
Comfort-Aire HSA1418S1-**A
Average cooling efficiency and below average heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.
Ranks #92 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $592 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.5 Cooling efficiency over a seasonAverage · beats 40%
- HSPF2
- 7.8 Heating efficiency over a seasonBelow average · beats 5%
- EER2
- 14.0 Cooling efficiency on a 95°F dayExcellent · beats 98%
- Heat at 5°F
- 8,500 BTU/h46% of its 47°F outputBelow average · beats 39%
A good fit if…
- You want a choice of indoor units - 40 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Comfort-Aire |
| Also sold as | Century |
| Outdoor unit model | HSA1418S1-**A |
| Series | HSA14 Series |
| Type | Central heat pump |
| Nominal size | 1.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 1, 2024 |
| Last certified | September 30, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.5 (range 15.2-16.5) |
| EER2Efficiency at 95°F outdoors | 13.0-14.0 |
| Cooling capacity | 18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8 |
| Capacity at 47°F | 17,500-18,000 BTU/h |
| Capacity at 17°F | 10,500-11,200 BTU/h |
| Capacity at 5°F | 7,900-8,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.86-2.00 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7EH30AX-**+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 7EH30AX-**+TDR | GUH80C045A3MP* | 16.5 | 14.0 | 7.8 | 8,100 | 216372545 |
| 7EH30AX-**+TDR | GUH80C070A3MP* | 16.5 | 14.0 | 7.8 | 8,100 | 216372546 |
| 7EH30AX-**+TDR | GUH80C045A3MP* | 16.5 | 14.0 | 7.8 | 8,100 | 216372651 |
| 7EH30AX-**+TDR | GUH80C070A3MP* | 16.5 | 14.0 | 7.8 | 8,100 | 216372652 |
| HMA24VX1*- | - | 16.0 | 13.8 | 7.8 | 8,400 | 216372643 |
| 7EH24AX-**+TDR | GUH80C070A3MP* | 16.0 | 13.8 | 7.8 | 8,000 | 216372647 |
| 7EH24BX-**+TDR | GUH80C070B3MP* | 16.0 | 13.8 | 7.8 | 8,200 | 216372648 |
| 7EH24BX-**+TDR | GUH92C045B3MP* | 16.0 | 13.8 | 7.8 | 8,300 | 216372649 |
| 7EH24BX-**+TDR | GUH92C070B3MP* | 16.0 | 13.8 | 7.8 | 8,300 | 216372650 |
| HMA18VX1*- | - | 16.0 | 13.6 | 7.8 | 8,100 | 216372534 |
| HMA18VX1*- | - | 16.0 | 13.6 | 7.8 | 8,100 | 216372640 |
| 7EH24AX-**+TDR | GUH80C070A3MP* | 16.0 | 13.8 | 7.8 | 8,000 | 216372541 |
| 7EH24AX-**+TDR | GUH80C045A3MP* | 16.0 | 13.8 | 7.8 | 7,900 | 216372540 |
| 7EH24BX-**+TDR | GUH80C070B3MP* | 16.0 | 13.8 | 7.8 | 8,200 | 216372542 |
| 7EH24BX-**+TDR | GUH92C070B3MP* | 16.0 | 13.8 | 7.8 | 8,300 | 216372544 |
| 7EH24BX-**+TDR | GUH92C045B3MP* | 16.0 | 13.8 | 7.8 | 8,300 | 216372543 |
| 7EH24AX-**+TDR | GUH80C045A3MP* | 16.0 | 13.8 | 7.8 | 7,900 | 216372646 |
| HMA24VX1*- | - | 16.0 | 13.8 | 7.8 | 8,400 | 216372537 |
| 7EH24BX-**+TDR | GUH97T045B3MP* | 16.0 | 13.6 | 7.8 | 8,200 | 216498813 |
| 7EH24BX-**+TDR | GUH97T045B3MP* | 16.0 | 13.6 | 7.8 | 8,200 | 216498782 |
| 7EH24BX-**+TDR | GUH97T070B3MP | 16.0 | 13.8 | 7.8 | 8,200 | 216801497 |
| 7EH24BX-**+TDR | GUH97T070B3MP | 16.0 | 13.8 | 7.8 | 8,200 | 216801527 |
| HMA24CX1*- | - | 16.0 | 13.8 | 7.8 | 8,200 | 217662726 |
| HMA24CX1*- | - | 16.0 | 13.8 | 7.8 | 8,200 | 217662732 |
| 7EH24AX-**+TDR | GUH80X040A3MP* | 15.5 | 13.6 | 7.8 | 8,000 | 216372644 |
| 7ED30/36BX-**+TDR | GDD96C045B3MP* | 15.5 | 13.2 | 7.8 | 8,400 | 216372550 |
| 7EH24AX-**+TDR | GUH80X040A3MP* | 15.5 | 13.6 | 7.8 | 8,000 | 216372538 |
| 7EH24AX-**+TDR | GUH80X060A3MP* | 15.5 | 13.6 | 7.8 | 8,000 | 216372539 |
| 7ED30/36BX-**+TDR | GDD92C045B3MP* | 15.5 | 13.2 | 7.8 | 8,400 | 216372654 |
| 7ED30/36BX-**+TDR | GDD92C070B3MP* | 15.5 | 13.2 | 7.8 | 8,400 | 216372655 |
| 7ED30/36BX-**+TDR | GDD96C045B3MP* | 15.5 | 13.2 | 7.8 | 8,400 | 216372656 |
| 7EH24AX-**+TDR | GUH80X060A3MP* | 15.5 | 13.6 | 7.8 | 8,000 | 216372645 |
| 7ED30/36BX-**+TDR | GDD92C045B3MP* | 15.5 | 13.2 | 7.8 | 8,400 | 216372548 |
| 7ED30/36BX-**+TDR | GDD92C070B3MP* | 15.5 | 13.2 | 7.8 | 8,400 | 216372549 |
| 7ED30/36BX-**+TDR | GDD80C070B3MP* | 15.2 | 13.0 | 7.8 | 8,400 | 216372547 |
| HMA24PX1*- | - | 15.2 | 13.2 | 7.8 | 8,400 | 216372535 |
| HMA24PX1*- | - | 15.2 | 13.2 | 7.8 | 8,400 | 216372641 |
| 7ED30/36BX-**+TDR | GDD80C070B3MP* | 15.2 | 13.0 | 7.8 | 8,400 | 216372653 |
| 7ED30/36BX-**+TDR | GDD96C070B4MP* | 15.2 | 13.0 | 7.8 | 8,500 | 216372657 |
| 7ED30/36BX-**+TDR | GDD96C070B4MP* | 15.2 | 13.0 | 7.8 | 8,500 | 216372551 |
Yearly running cost in 10 large cities
- Phoenix, AZ$641/yr
- Miami, FL$514/yr
- Houston, TX$574/yr
- Atlanta, GA$592/yr
- Los Angeles, CA$578/yr
- New York, NY$1,428/yr
- Chicago, IL$1,162/yr
- Denver, CO$968/yr
- Seattle, WA$596/yr
- Minneapolis, MN$1,199/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Comfort-Aire HSA1418S1-**A?
- The Comfort-Aire HSA1418S1-**A is rated at up to 16.5 SEER2 and 14.0 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 40 certified matchups SEER2 ranges from 15.2-16.5.
- Is the Comfort-Aire HSA1418S1-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
- How much does the Comfort-Aire HSA1418S1-**A cost to run per year?
- At its rated efficiency it costs about $514-$1,428 a year in electricity in large U.S. cities, depending on climate and local rates - for example $641 in Phoenix and $1,199 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Comfort-Aire HSA1418S1-**A?
- ENERGY STAR lists 40 certified combinations for this outdoor unit. The highest-rated ones use 7EH30AX-**+TDR, HMA24VX1*-, 7EH24AX-**+TDR.
- What refrigerant does the Comfort-Aire HSA1418S1-**A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 1.5 ton models
- AIREASE A7HP14F18P-**A16.5 SEER2 · 7.8 HSPF2
- Concord 7HP14F18P-**A16.5 SEER2 · 7.8 HSPF2
- AC Pro BH714S18P-**A16.5 SEER2 · 7.8 HSPF2
- GE NS16H18SA5-**A16.5 SEER2 · 7.8 HSPF2
- Daikin DH6VSA181MA16.5 SEER2 · 8.5 HSPF2
- Lennox EL16KP1-018-230A16.5 SEER2 · 7.8 HSPF2
- MDV MOX330U-18HFN1-MR016.5 SEER2 · 8.6 HSPF2
- Lennox ML14KP1-018-230A16.5 SEER2 · 7.8 HSPF2
See all 170 1.5 ton central heat pumps, ranked