HVAC Rated

2-ton central heat pump · GZV9SA

Goodman GZV9SA241CA

Excellent cooling efficiency and very good heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #12 of 331 2 ton central heat pumps for cooling efficiency, and costs about $583 a year to run in a mixed climate like Atlanta.

SEER2
21.0 Cooling efficiency over a season
Excellent · beats 97%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
12.2 Cooling efficiency on a 95°F day
Very good · beats 75%
Heat at 5°F
24,000 BTU/h100% of its 47°F output
Excellent · beats 95%

A good fit if…

  • You want low cooling bills - its SEER2 beats 97% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 24,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-32
General
BrandGoodman
Outdoor unit modelGZV9SA241CA
SeriesGZV9SA
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableYes
On the market sinceNovember 10, 2025
Last certifiedJanuary 20, 2026
Cooling
SEER2Seasonal efficiency, higher is better21.0 (range 16.9-21.0)
EER2Efficiency at 95°F outdoors11.7-12.2
Cooling capacity23,000-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-10.0
Capacity at 47°F21,000-24,000 BTU/h
Capacity at 17°F21,000-24,000 BTU/h
Capacity at 5°F21,000-24,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.40
ENERGY STAR cold climateYes
Heating output as it gets colder100% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CAHEA3630C3A*+MBVK16CH*X00A at the standard test temperatures, in BTU/h:

Certified matchups43 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CAHEA3630C3A*+MBVK16CH*X00A · cold climate-21.012.210.024,000216699795
CA*EA4830*3A · cold climateG*VT960803BNA*19.211.79.222,000217970981
CA*EA4830*3A · cold climateG*VT960603BNA*19.211.79.222,000217970983
CA*EA4830*3A · cold climateG*VT800803B*A*19.211.79.222,000217970985
CA*EA4830*3A · cold climateG*VT800604B*A*19.211.79.222,000217970987
CA*EA4830*3A · cold climateG*VT800603B*A*19.211.79.222,000217970989
CA*EA4830*3A · cold climateG*VS960603BUA*19.211.79.222,000217970991
CA*EA4830*3A · cold climateG*VS800604BUA*19.211.79.222,000217970993
CA*EA4830*3A · cold climateG*VM970803BNA*19.211.79.222,000217970995
CA*EA4830*3A · cold climateG*VM970603BNA*19.211.79.222,000217970997
CA*EA4830*3A · cold climateG*VT960403BNA*19.211.79.222,000217971005
CA*EA4830*3A · cold climateG*VM970804CNA*19.211.79.222,000216699910
CA*EA4830*3A · cold climateG*VM971005CNA*19.211.79.222,000216699908
CA*EA4830*3A · cold climateG*VS800805CUA*19.211.79.222,000216699906
CA*EA4830*3A · cold climateG*VS960805CUA*19.211.79.222,000216699904
CA*EA4830*3A · cold climateG*VT800804C*A*19.211.79.222,000216699902
CA*EA4830*3A · cold climateG*VT800805C*A*19.211.79.222,000216699900
CA*EA4830*3A · cold climateG*VT801005C*A*19.211.79.222,000216699898
CA*EA4830*3A · cold climateG*VT960804CNA*19.211.79.222,000216699896
CA*EA4830*3A · cold climateG*VT961005CNA*19.211.79.222,000216699894
CA*EA4830*3A*+MBVK16CP1X00A · cold climate-19.211.79.222,000216699892
AHVE48CP0300A · cold climate-19.211.79.222,400216699890
AHVE48CP1300A · cold climate-19.211.79.222,400216699889
CHPEA4830*3A · cold climateG*VT960803BNA*18.211.79.021,000217970980
CHPEA4830*3A · cold climateG*VT960603BNA*18.211.79.021,000217970982
CHPEA4830*3A · cold climateG*VT800803B*A*18.211.79.021,000217970984
CHPEA4830*3A · cold climateG*VT800604B*A*18.211.79.021,000217970986
CHPEA4830*3A · cold climateG*VT800603B*A*18.211.79.021,000217970988
CHPEA4830*3A · cold climateG*VS800604BUA*18.211.79.021,000217970992
CHPEA4830*3A · cold climateG*VM970603BNA*18.211.79.021,000217970994
CHPEA4830*3A · cold climateG*VS960603BUA*18.211.79.021,000217970990
CHPEA4830*3A · cold climateG*VM970803BNA*18.211.79.021,000217970996
CHPEA4830*3A · cold climateG*VT960403BNA*18.211.79.021,000217970998
CHPEA4830*3A · cold climateG*VM970804CNA*18.211.79.021,000216699909
CHPEA4830*3A · cold climateG*VM971005CNA*18.211.79.021,000216699907
CHPEA4830*3A · cold climateG*VS800805CUA*18.211.79.021,000216699905
CHPEA4830*3A · cold climateG*VS960805CUA*18.211.79.021,000216699903
CHPEA4830*3A · cold climateG*VT800804C*A*18.211.79.021,000216699901
CHPEA4830*3A · cold climateG*VT800805C*A*18.211.79.021,000216699899
CHPEA4830*3A · cold climateG*VT801005C*A*18.211.79.021,000216699897
CHPEA4830*3A*+MBVK16CP1X00A · cold climate-18.211.79.021,000216699891
CHPEA4830*3A · cold climateG*VT961005CNA*18.211.78.521,000216699893
CHPEA4830*3A · cold climateG*VT960804CNA*16.911.79.021,000216699895
Yearly running cost in 10 large cities$523-$1,392

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Goodman GZV9SA241CA?
The Goodman GZV9SA241CA is rated at up to 21.0 SEER2 and 12.2 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 43 certified matchups SEER2 ranges from 16.9-21.0.
Is the Goodman GZV9SA241CA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 24,000 BTU/h at 5°F with a COP of 2.40, so it is still 2.4 times as efficient as electric resistance heat at that temperature.
How much does the Goodman GZV9SA241CA cost to run per year?
At its rated efficiency it costs about $523-$1,392 a year in electricity in large U.S. cities, depending on climate and local rates - for example $644 in Phoenix and $1,162 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Goodman GZV9SA241CA?
ENERGY STAR lists 43 certified combinations for this outdoor unit. The highest-rated ones use CAHEA3630C3A*+MBVK16CH*X00A, CA*EA4830*3A, CA*EA4830*3A*+MBVK16CP1X00A.
What refrigerant does the Goodman GZV9SA241CA use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $639/yrYou save $545/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Goodman GZV9SA241CA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$639
Current system, per year
$1,184
You save per year
$545
Payback
16.5 years
Net after 10 years
-$3,550

Cooling $392Heating $246Electricity used: 3,991 kWhSaved vs. a minimum-efficiency heat pump: $266

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 20, 2026. How we use the data.