HVAC Rated

5-ton central heat pump · ProComfort 20 VS HP

Keeprite C5H0V60*K*AAA

Very good cooling efficiency and average heating efficiency for a 5-ton central heat pump, and certified for cold climates.

Ranks #14 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,734 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Very good · beats 85%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
9.5 Cooling efficiency on a 95°F day
Below average · beats 5%
Heat at 5°F
46,000 BTU/h70% of its 47°F output
Average · beats 58%

A good fit if…

  • You want low cooling bills - its SEER2 beats 85% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 46,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 474 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications5 ton, R-454B
General
BrandKeeprite
Also sold asComfortmaker, Day & Night
Outdoor unit modelC5H0V60*K*AAA
SeriesProComfort 20 VS HP
TypeCentral heat pump
Nominal size5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 12, 2023
Last certifiedMay 1, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 16.5-19.0)
EER2Efficiency at 95°F outdoors8.0-9.8
Cooling capacity54,000-58,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-9.0
Capacity at 47°F59,000-63,500 BTU/h
Capacity at 17°F50,500-57,500 BTU/h
Capacity at 5°F41,000-46,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.86-2.10
ENERGY STAR cold climateYes
Heating output as it gets colder70% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EVM5X61M24A*+WALLCON at the standard test temperatures, in BTU/h:

Certified matchups474 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 474 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EVM5X61M24A*+WALLCON · cold climate*80CSU0802120A*19.09.59.044,500215677218
EVM5X61M24A*+WALLCON · cold climate*80CSU0802120A*19.09.59.044,500215677219
EVM5X61M24A*+WALLCON · cold climate*80CSU0802120A*19.09.59.044,500215677220
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.09.59.044,500215677239
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.09.59.044,500215677238
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.09.59.044,500215677240
EVM5X61M24A*+WALLCON · cold climate*96CTN1202422B*19.09.59.044,500215677308
EVM5X61M24A*+WALLCON · cold climate*96CTN1202422B*19.09.59.044,500215677309
EVM5X61M24A*+WALLCON · cold climate*96CTN1202422B*19.09.59.044,500215677310
EVD5X61M21A*+WALLCON · cold climate*80CTL0902120B*19.09.59.044,500215677589
EVD5X61M21A*+WALLCON · cold climate*80CTL0902120B*19.09.59.044,500215677588
EVD5X61M21A*+WALLCON · cold climate*80CTL0902120B*19.09.59.044,500215677590
EVD5X61M24A*+WALLCON · cold climate*80CSU0802120A*19.09.59.044,500215677638
EVD5X61M24A*+WALLCON · cold climate*80CSU0802120A*19.09.59.044,500215677639
EVD5X61M24A*+WALLCON · cold climate*80CSU0802120A*19.09.59.044,500215677640
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.09.59.044,500215677659
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.09.59.044,500215677660
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.09.59.044,500215677658
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.09.59.044,500215677669
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.09.59.044,500215677668
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.09.59.044,500215677670
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.09.09.041,500215677929
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.09.09.041,500215677928
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.09.09.041,500215677930
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.09.09.041,500215677939
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.09.09.041,500215677938
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.09.09.041,500215677940
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.09.09.041,500215677948
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.09.09.041,500215677950
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.09.09.041,500215677949
EVM5X61M24A*+WALLCON · cold climate*97CTN1202422A*19.09.59.044,500215682979
EVM5X61M24A*+WALLCON · cold climate*97CTN1202422A*19.09.59.044,500215682978
EVM5X61M24A*+WALLCON · cold climate*97CTN1202422A*19.09.59.044,500215682980
EVD5X61M24A*+WALLCON · cold climate*97CTN1202422A*19.09.89.044,500215683240
EVD5X61M24A*+WALLCON · cold climate*97CTN1202422A*19.09.89.044,500215683238
EVD5X61M24A*+WALLCON · cold climate*97CTN1202422A*19.09.89.044,500215683239
EVM5X60M24A*+WALLCON · cold climate*97CMN1002122B*18.59.09.044,500215677178
EVM5X60M24A*+WALLCON · cold climate*97CMN1002122B*18.59.09.044,500215677179
EVM5X60M24A*+WALLCON · cold climate*97CMN1002122B*18.59.09.044,500215677180
EVM5X60M24A*+WALLCON · cold climate*97CMN1202422B*18.59.09.044,500215677188
EVM5X60M24A*+WALLCON · cold climate*97CMN1202422B*18.59.09.044,500215677190
EVM5X60M24A*+WALLCON · cold climate*97CMN1202422B*18.59.09.044,500215677189
EVM5X60M24A*+WALLCON · cold climate*96CTN1002122B*18.59.09.044,500215677198
EVM5X60M24A*+WALLCON · cold climate*96CTN1002122B*18.59.09.044,500215677199
EVM5X60M24A*+WALLCON · cold climate*96CTN1002122B*18.59.09.044,500215677200
EVM5X60M21A*+WALLCON · cold climate*80CTL0902120B*18.59.59.044,500215677008
EVM5X60M21A*+WALLCON · cold climate*80CTL0902120B*18.59.59.044,500215677009
EVM5X60M21A*+WALLCON · cold climate*80CTL0902120B*18.59.59.044,500215677010
EVM5X60M21A*+WALLCON · cold climate*80CTL1102120B*18.59.59.044,500215677018
EVM5X60M21A*+WALLCON · cold climate*80CTL1102120B*18.59.59.044,500215677019
EVM5X60M21A*+WALLCON · cold climate*80CTL1102120B*18.59.59.044,500215677020
EVM5X60M24A*+WALLCON · cold climate*96CTN1202422B*18.59.09.044,500215677210
EVM5X60M24A*+WALLCON · cold climate*96CTN1202422B*18.59.09.044,500215677208
EVM5X60M24A*+WALLCON · cold climate*96CTN1202422B*18.59.09.044,500215677209
EVM5X61M24A*+WALLCON · cold climate*80CTL0702120B*18.59.09.045,000215677229
EVM5X61M24A*+WALLCON · cold climate*80CTL0702120B*18.59.09.045,000215677230
EVM5X61M24A*+WALLCON · cold climate*80CTL0702120B*18.59.09.045,000215677228
EVM5X61M24A*+WALLCON · cold climate*95CSU1002122B*18.59.59.044,500215677260
EVM5X61M24A*+WALLCON · cold climate*95CSU1002122B*18.59.59.044,500215677259
EVM5X61M24A*+WALLCON · cold climate*95CSU1002122B*18.59.59.044,500215677258
Yearly running cost in 10 large cities$1,405-$4,262

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Keeprite C5H0V60*K*AAA?
The Keeprite C5H0V60*K*AAA is rated at up to 19.0 SEER2 and 9.5 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 474 certified matchups SEER2 ranges from 16.5-19.0.
Is the Keeprite C5H0V60*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 46,000 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Keeprite C5H0V60*K*AAA cost to run per year?
At its rated efficiency it costs about $1,405-$4,262 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,802 in Phoenix and $3,614 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Keeprite C5H0V60*K*AAA?
ENERGY STAR lists 474 certified combinations for this outdoor unit. The highest-rated ones use EVM5X61M24A*+WALLCON, EVD5X61M21A*+WALLCON, EVD5X61M24A*+WALLCON.
What refrigerant does the Keeprite C5H0V60*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,825/yrYou save $1,187/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Keeprite C5H0V60*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,825
Current system, per year
$3,011
You save per year
$1,187
Payback
17.7 years
Net after 10 years
-$9,131

Cooling $1,047Heating $778Electricity used: 11,403 kWhSaved vs. a minimum-efficiency heat pump: $500

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 5 ton models

See all 100 5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 1, 2026. How we use the data.