2.5-ton central heat pump · A Series
KERR A-KXP30SA-1
Average cooling efficiency and very good heating efficiency for a 2.5-ton central heat pump, and certified for cold climates.
Ranks #97 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $835 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.8 Cooling efficiency over a seasonAverage · beats 45%
- HSPF2
- 10.0 Heating efficiency over a seasonVery good · beats 84%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 32,600 BTU/h96% of its 47°F outputBelow average · beats 29%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 32,600 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | KERR |
| Outdoor unit model | A-KXP30SA-1 |
| Series | A Series |
| Type | Central heat pump |
| Nominal size | 2.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | March 20, 2025 |
| Last certified | June 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.8 (range 15.3-16.8) |
| EER2Efficiency at 95°F outdoors | 10.0-11.7 |
| Cooling capacity | 29,000-30,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.3-10.0 |
| Capacity at 47°F | 30,000-34,000 BTU/h |
| Capacity at 17°F | 23,800-25,000 BTU/h |
| Capacity at 5°F | 30,400-32,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-1.96 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with B-KXP30SA-1 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| B-KXP30SA-1 · cold climate | 16.8 | 11.7 | 10.0 | 32,600 | 217169712 |
| KXP24/36B1A · cold climate | 16.0 | 11.0 | 9.6 | 32,000 | 217482397 |
| KXP24/36C1A · cold climate | 16.0 | 11.0 | 9.6 | 32,000 | 217482398 |
| MXP30/36B1A · cold climate | 16.0 | 11.0 | 9.6 | 32,000 | 217542262 |
| MXP30/36C1A · cold climate | 16.0 | 11.0 | 9.6 | 32,000 | 217542263 |
| KXP24/36A1A · cold climate | 15.3 | 10.0 | 9.3 | 30,400 | 217482396 |
| MXP30/36A1A · cold climate | 15.3 | 10.0 | 9.3 | 30,400 | 217542261 |
Yearly running cost in 10 large cities
- Phoenix, AZ$966/yr
- Miami, FL$808/yr
- Houston, TX$865/yr
- Atlanta, GA$835/yr
- Los Angeles, CA$804/yr
- New York, NY$1,948/yr
- Chicago, IL$1,572/yr
- Denver, CO$1,299/yr
- Seattle, WA$792/yr
- Minneapolis, MN$1,604/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the KERR A-KXP30SA-1?
- The KERR A-KXP30SA-1 is rated at up to 16.8 SEER2 and 11.7 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 7 certified matchups SEER2 ranges from 15.3-16.8.
- Is the KERR A-KXP30SA-1 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 32,600 BTU/h at 5°F with a COP of 1.96, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the KERR A-KXP30SA-1 cost to run per year?
- At its rated efficiency it costs about $792-$1,948 a year in electricity in large U.S. cities, depending on climate and local rates - for example $966 in Phoenix and $1,604 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the KERR A-KXP30SA-1?
- ENERGY STAR lists 7 certified combinations for this outdoor unit. The highest-rated ones use B-KXP30SA-1, KXP24/36B1A, KXP24/36C1A.
- What refrigerant does the KERR A-KXP30SA-1 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2.5 ton models
- Elios ESHMA30R2AN1 · cold climate16.8 SEER2 · 10.0 HSPF2
- Panasonic CU-HM30BAHU · cold climate16.8 SEER2 · 10.0 HSPF2
- ECO-AIR ECUO-30H · cold climate16.8 SEER2 · 10.0 HSPF2
- TRUST AIR CONDITIONERS AA30H/O64P · cold climate16.8 SEER2 · 10.0 HSPF2
- DIRECT AIR DIRM4-30MAGICPRO20-OU · cold climate16.8 SEER2 · 10.0 HSPF2
- ZERO ZSOVA-30HDMB-USHH · cold climate16.8 SEER2 · 10.0 HSPF2
- Custom Comfort CCOXHB24V30HP · cold climate16.8 SEER2 · 10.0 HSPF2
- Lennox ML15KSPV-030-230A16.7 SEER2 · 9.2 HSPF2
See all 199 2.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 27, 2025. How we use the data.