HVAC Rated

2.5-ton central heat pump · ELITE EL17XP1 Series

Lennox EL17XP1-030-230A

Below average cooling efficiency and average heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.

Ranks #119 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $895 a year to run in a mixed climate like Atlanta.

SEER2
16.2 Cooling efficiency over a season
Below average · beats 36%
HSPF2
8.6 Heating efficiency over a season
Average · beats 45%
EER2
13.5 Cooling efficiency on a 95°F day
Excellent · beats 95%
Heat at 5°F
15,400 BTU/h49% of its 47°F output
Excellent · beats 94%

A good fit if…

  • You want a choice of indoor units - 448 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2.5 ton, R-410A
General
BrandLennox
Outdoor unit modelEL17XP1-030-230A
SeriesELITE EL17XP1 Series
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 6, 2022
Last certifiedOctober 27, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.2 (range 15.2-16.2)
EER2Efficiency at 95°F outdoors12.2-13.5
Cooling capacity28,200-30,600 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.6
Capacity at 47°F26,600-30,000 BTU/h
Capacity at 17°F17,200-19,600 BTU/h
Capacity at 5°F13,200-15,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.96-2.38
ENERGY STAR cold climateNo
Heating output as it gets colder49% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CRX35-42B-**-*+TDR at the standard test temperatures, in BTU/h:

Certified matchups448 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 448 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CRX35-42B-**-*+TDRML180DF090E48B*16.213.58.614,800213257760
CK40DT-42B-0*+TDRML180DF090E48B*16.213.58.614,800214622305
CX35-36B+TDRML180UH070V48B*16.213.08.114,400210291921
C35-36B+TDR+TXVML180UH070V36B*16.213.08.114,500210291639
CX35-36B+TDRSL280UH080NV48B*16.213.08.114,500210291934
CX35-36B+TDREL280UH090E36B*16.213.08.114,300210291910
C35-36B+TDR+TXVML180UH090E48B*16.213.08.114,100210291641
C35-36B+TDR+TXVML180UH070V48B*16.213.08.114,400210291640
C35-36B+TDR+TXVSL280UH080NV48B*16.213.08.114,500210291652
CX35-36B+TDRSL280UH090V36B*16.213.08.114,500210291935
CX35-36A+TDRSL280UH060NV36A*16.213.08.114,500210291900
CX35-36B+TDREL280UH090XE48B*16.213.08.114,100210291913
C35-36A+TDR+TXVSL280UH060NV36A*16.213.08.114,500210291618
CX35-36B+TDRML180UH090E48B*16.213.08.114,100210291922
CX35-36B+TDREL280UH090E48B*16.213.08.114,100210291911
C35-36B+TDR+TXVEL280UH090E36B*16.213.08.114,300210291629
CX35-36B+TDRML180UH070V36B*16.213.08.114,500210291920
C35-36B+TDR+TXVEL280UH090E48B*16.213.08.114,100210291630
C35-36B+TDR+TXVEL280UH090XE48B*16.213.08.114,100210291631
C35-36B+TDR+TXVSL280UH090V36B*16.213.08.114,500210291653
CK40CT-36A-0*+TDRSL280UH060NV36A*16.213.08.114,500214622374
CK40CT-36B-0*+TDREL280UH090E48B*16.213.08.114,100214622385
CK40CT-36B-0*+TDREL280UH090E36B*16.213.08.114,300214622384
CK40CT-36B-0*+TDREL280UH090XE48B*16.213.08.114,100214622386
CK40CT-36B-0*+TDRML180UH070V36B*16.213.08.114,500214622392
CK40CT-36B-0*+TDRML180UH070V48B*16.213.08.114,400214622393
CK40CT-36B-0*+TDRML180UH090E48B*16.213.08.114,100214622394
CK40CT-36B-0*+TDRSL280UH080NV48B*16.213.08.114,500214622405
CK40CT-36B-0*+TDRSL280UH090V36B*16.213.08.114,500214622406
CHX35-30B-**-*+TDRML180UH070V36B*16.213.08.013,700212442671
CHX35-30B-**-*+TDREL280UH090E36B*16.213.08.013,500212442663
CHX35-30B-**-*+TDRML180UH070V48B*16.213.08.013,700212442672
CHX35-30B-**-*+TDRSL280UH080NV48B*16.213.08.013,800212442684
CHX35-30B-**-*+TDRSL280UH090V36B*16.213.08.013,800212442685
CK40HT-30B-0*+TDREL280UH090E36B*16.213.08.013,500214622228
CK40HT-30B-0*+TDRML180UH070V36B*16.213.08.013,700214622236
CK40HT-30B-0*+TDRML180UH070V48B*16.213.08.013,700214622237
CK40HT-30B-0*+TDRSL280UH080NV48B*16.213.08.013,800214622249
CK40HT-30B-0*+TDRSL280UH090V36B*16.213.08.013,800214622250
CHX35-30B-**-*+TDRML180UH070E36B*16.213.07.813,400212442670
CHX35-30B-**-*+TDREL280UH090XE48B*16.213.07.813,400212442665
CHX35-30B-**-*+TDREL280UH090E48B*16.213.07.813,400212442664
CHX35-30B-**-*+TDRML180UH090E48B*16.213.07.813,400212442673
CK40HT-30B-0*+TDREL280UH090XE48B*16.213.07.813,400214622230
CK40HT-30B-0*+TDREL280UH090E48B*16.213.07.813,400214622229
CK40HT-30B-0*+TDRML180UH070E36B*16.213.07.813,400214622235
CK40HT-30B-0*+TDRML180UH090E48B*16.213.07.813,400214622238
CBA38MV-030-230*+TDR-16.013.08.515,000210291661
CBK45UHET-036-230-0-16.012.58.513,200214861288
CX35-36B+TDRSLP99UH070XV36B*16.013.08.114,500210291939
CX35-36B+TDRML193UH070XE36B*16.013.08.114,400210291926
C35-36B+TDR+TXVSL297UH040NV36B*16.013.08.114,400210291656
CX35-36B+TDRSL297UH040NV36B*16.013.08.114,400210291937
C35-36B+TDR+TXVML193UH070XE36B*16.013.08.114,400210291645
C35-36B+TDR+TXVSLP99UH070XV36B*16.013.08.114,500210291658
C35-36B+TDR+TXVML180UH090V48B*16.013.08.114,500210291642
CX35-36A+TDRML180UH070E36A*16.013.08.114,400210291897
C35-36A+TDR+TXVEL280UH070E36A*16.013.08.114,300210291608
CX35-36B+TDRSL280UH090V48B*16.013.08.114,400210291936
C35-30A+TDR+TXVSL280UH060NV36A*16.013.08.114,300210291555
Yearly running cost in 10 large cities$850-$2,100

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Lennox EL17XP1-030-230A?
The Lennox EL17XP1-030-230A is rated at up to 16.2 SEER2 and 13.5 EER2 for cooling and up to 8.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 448 certified matchups SEER2 ranges from 15.2-16.2.
Is the Lennox EL17XP1-030-230A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
How much does the Lennox EL17XP1-030-230A cost to run per year?
At its rated efficiency it costs about $850-$2,100 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,024 in Phoenix and $1,736 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Lennox EL17XP1-030-230A?
ENERGY STAR lists 448 certified combinations for this outdoor unit. The highest-rated ones use CRX35-42B-**-*+TDR, CK40DT-42B-0*+TDR, CX35-36B+TDR.
What refrigerant does the Lennox EL17XP1-030-230A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,003/yrYou save $490/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Lennox EL17XP1-030-230A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,003
Current system, per year
$1,493
You save per year
$490
Payback
22.5 years
Net after 10 years
-$6,104

Cooling $639Heating $365Electricity used: 6,272 kWhSaved vs. a minimum-efficiency heat pump: $138

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.