4-ton central heat pump · MDV Series
Midea MDV-V60WMN10T(A)
Very good cooling and heating efficiency for a 4-ton central heat pump, and certified for cold climates.
Ranks #53 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,450 a year to run in a mixed climate like Atlanta.
- SEER2
- 19.0 Cooling efficiency over a seasonVery good · beats 85%
- HSPF2
- 9.8 Heating efficiency over a seasonVery good · beats 79%
- EER2
- 9.5 Cooling efficiency on a 95°F dayBelow average · beats 5%
- Heat at 5°F
- 42,000 BTU/h70% of its 47°F outputBelow average · beats 27%
A good fit if…
- You want low cooling bills - its SEER2 beats 85% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 42,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 79% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Midea |
| Outdoor unit model | MDV-V60WMN10T(A) |
| Series | MDV Series |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 6, 2025 |
| Last certified | April 27, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 19.0 (range 15.5-19.0) |
| EER2Efficiency at 95°F outdoors | 9.0-10.2 |
| Cooling capacity | 43,000-60,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.0-9.8 |
| Capacity at 47°F | 44,000-60,000 BTU/h |
| Capacity at 17°F | 36,000-42,000 BTU/h |
| Capacity at 5°F | 31,000-42,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-1.95 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| - MIDEA · cold climate | - | 19.0 | 9.5 | 9.8 | 42,000 | 217992176 |
| - MIDEA · cold climate | - | 17.8 | 9.3 | 9.4 | 42,000 | 217992177 |
| MIH48VMN10 · cold climate | - | 17.0 | 10.2 | 9.0 | 39,000 | 217992227 |
| - MIDEA · cold climate | - | 16.5 | 9.0 | 9.0 | 42,000 | 217992169 |
| MVME48C2MN10TB · cold climate | - | 16.5 | 10.0 | 9.0 | 39,000 | 217992225 |
| MVME48C2MN10TD · cold climate | - | 16.5 | 10.0 | 9.0 | 39,000 | 218159716 |
| MIH54VMN10 · cold climate | - | 16.5 | 9.5 | 8.5 | 42,000 | 217992249 |
| MCPM4860CN10TH · cold climate | MGV97U100C5A | 15.5 | 9.5 | 8.6 | 37,000 | 217992220 |
| MCPM4860DN10TH · cold climate | MGV97U100D5A | 15.5 | 9.5 | 8.6 | 40,000 | 217992221 |
| MCPM4860DN10TH · cold climate | MGV97U120D5A | 15.5 | 9.5 | 8.6 | 37,000 | 217992222 |
| MVME60C2MN10TB · cold climate | - | 15.5 | 9.5 | 8.5 | 42,000 | 217992226 |
| MVME60C2MN10TD · cold climate | - | 15.5 | 9.5 | 8.5 | 42,000 | 218159717 |
| MC**4248BN10TH · cold climate | MGV97U080B3A | 15.5 | 10.0 | 8.1 | 31,000 | 217992215 |
| MC**4248CN10TH · cold climate | MGV97U080C4A | 15.5 | 10.0 | 8.1 | 31,600 | 217992216 |
| MC**4248CN10TH · cold climate | MGV97U100C5A | 15.5 | 10.0 | 8.1 | 33,000 | 217992217 |
| MC**4248DN10TH · cold climate | MGV97U100D5A | 15.5 | 10.0 | 8.1 | 33,000 | 217992218 |
| MC**4248DN10TH · cold climate | MGV97U120D5A | 15.5 | 10.0 | 8.0 | 33,000 | 217992219 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,591/yr
- Miami, FL$1,287/yr
- Houston, TX$1,426/yr
- Atlanta, GA$1,450/yr
- Los Angeles, CA$1,412/yr
- New York, NY$3,473/yr
- Chicago, IL$2,821/yr
- Denver, CO$2,347/yr
- Seattle, WA$1,443/yr
- Minneapolis, MN$2,905/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Midea MDV-V60WMN10T(A)?
- The Midea MDV-V60WMN10T(A) is rated at up to 19.0 SEER2 and 9.5 EER2 for cooling and up to 9.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 17 certified matchups SEER2 ranges from 15.5-19.0.
- Is the Midea MDV-V60WMN10T(A) good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 42,000 BTU/h at 5°F with a COP of 1.95, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Midea MDV-V60WMN10T(A) cost to run per year?
- At its rated efficiency it costs about $1,287-$3,473 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,591 in Phoenix and $2,905 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Midea MDV-V60WMN10T(A)?
- ENERGY STAR lists 17 certified combinations for this outdoor unit. The highest-rated ones use MIH48VMN10, MVME48C2MN10TB, MVME48C2MN10TD.
- What refrigerant does the Midea MDV-V60WMN10T(A) use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- Bosch BOHA-60RTB-M18S · cold climate19.0 SEER2 · 9.8 HSPF2
- LG KUSXA482A · cold climate19.0 SEER2 · 9.6 HSPF2
- York YDC60E2D11 · cold climate19.0 SEER2 · 10.0 HSPF2
- GREE FXU60HP230V1R45AO · cold climate19.0 SEER2 · 9.5 HSPF2
- TOSOT TUD60-48W2/NHE-D(U) · cold climate19.0 SEER2 · 10.0 HSPF2
- GREE GUD60W2/NXF-D(U) · cold climate19.0 SEER2 · 9.5 HSPF2
- TOSOT TU60-48WEDU · cold climate19.0 SEER2 · 10.0 HSPF2
- Napoleon WSEHV4860BA1-N · cold climate19.0 SEER2 · 9.5 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of April 27, 2026. How we use the data.