4-ton central heat pump · F Series
Napoleon WSEHV4860BA1-N
Very good cooling and heating efficiency for a 4-ton central heat pump, and certified for cold climates.
Ranks #57 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,478 a year to run in a mixed climate like Atlanta.
- SEER2
- 19.0 Cooling efficiency over a seasonVery good · beats 85%
- HSPF2
- 9.5 Heating efficiency over a seasonVery good · beats 70%
- EER2
- 11.5 Cooling efficiency on a 95°F dayBelow average · beats 31%
- Heat at 5°F
- 48,000 BTU/h84% of its 47°F outputBelow average · beats 12%
A good fit if…
- You want low cooling bills - its SEER2 beats 85% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 48,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Napoleon |
| Outdoor unit model | WSEHV4860BA1-N |
| Series | F Series |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 6, 2024 |
| Last certified | September 1, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 19.0 (range 16.0-19.0) |
| EER2Efficiency at 95°F outdoors | 10.0-11.5 |
| Cooling capacity | 47,000-54,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.5-9.5 |
| Capacity at 47°F | 48,000-54,000 BTU/h |
| Capacity at 17°F | 34,000-44,000 BTU/h |
| Capacity at 5°F | 40,500-48,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.75-1.85 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with WPFX48A-N at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| WPFX48A-N · cold climate | 19.0 | 11.5 | 9.5 | 40,500 | 216626013 |
| WPFX60A-N · cold climate | 18.5 | 10.5 | 9.5 | 43,000 | 216025739 |
| WPCC48ABA1-N · cold climate | 16.0 | 11.0 | 8.8 | 47,000 | 217463584 |
| WPCC48ABA1 · cold climate | 16.0 | 11.0 | 8.8 | 47,000 | 218700911 |
| WPCC60ABA1-N · cold climate | 16.0 | 10.0 | 8.5 | 48,000 | 217463582 |
| WPCC60ABA1 · cold climate | 16.0 | 10.0 | 8.5 | 48,000 | 218700912 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,604/yr
- Miami, FL$1,288/yr
- Houston, TX$1,438/yr
- Atlanta, GA$1,478/yr
- Los Angeles, CA$1,444/yr
- New York, NY$3,561/yr
- Chicago, IL$2,897/yr
- Denver, CO$2,413/yr
- Seattle, WA$1,486/yr
- Minneapolis, MN$2,988/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Napoleon WSEHV4860BA1-N?
- The Napoleon WSEHV4860BA1-N is rated at up to 19.0 SEER2 and 11.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 6 certified matchups SEER2 ranges from 16.0-19.0.
- Is the Napoleon WSEHV4860BA1-N good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 48,000 BTU/h at 5°F with a COP of 1.85, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the Napoleon WSEHV4860BA1-N cost to run per year?
- At its rated efficiency it costs about $1,288-$3,561 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,604 in Phoenix and $2,988 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Napoleon WSEHV4860BA1-N?
- ENERGY STAR lists 6 certified combinations for this outdoor unit. The highest-rated ones use WPFX48A-N, WPFX60A-N, WPCC48ABA1-N.
- What refrigerant does the Napoleon WSEHV4860BA1-N use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- GREE GUD60W2/NXF-D(U) · cold climate19.0 SEER2 · 9.5 HSPF2
- TOSOT TU60-32GDU19.0 SEER2 · 9.5 HSPF2
- GREE FXU60HP230V1R45AO · cold climate19.0 SEER2 · 9.5 HSPF2
- Trane 5HCL5060B1 · cold climate19.0 SEER2 · 9.5 HSPF2
- LG KUSXA482A · cold climate19.0 SEER2 · 9.6 HSPF2
- Trane 5TWV0X60A1 · cold climate19.0 SEER2 · 9.4 HSPF2
- Midea MDV-V60WMN10T(A) · cold climate19.0 SEER2 · 9.8 HSPF2
- American Standard 4A6L9048A119.0 SEER2 · 9.0 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 1, 2026. How we use the data.