1.5-ton central heat pump · MAINLINE 16 SEER2 HP
Tempstar T5H6S19*K*AAA
Below average cooling and heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.
Ranks #133 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $636 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 8.0 Heating efficiency over a seasonBelow average · beats 12%
- EER2
- 13.0 Cooling efficiency on a 95°F dayVery good · beats 89%
- Heat at 5°F
- 8,500 BTU/h43% of its 47°F outputBelow average · beats 39%
A good fit if…
- You want a choice of indoor units - 76 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Tempstar |
| Also sold as | Kenmore |
| Outdoor unit model | T5H6S19*K*AAA |
| Series | MAINLINE 16 SEER2 HP |
| Type | Central heat pump |
| Nominal size | 1.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | July 31, 2025 |
| Last certified | July 17, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 12.5-13.0 |
| Cooling capacity | 17,700-19,300 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.0 |
| Capacity at 47°F | 18,400-19,500 BTU/h |
| Capacity at 17°F | 10,300-11,000 BTU/h |
| Capacity at 5°F | 7,900-8,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.90-2.00 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EA*5X25M17A at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 76 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| EA*5X25M17A | *80VSL0901716B* | 16.0 | 13.0 | 8.0 | 8,400 | 217722519 |
| EA*5X25M17A | *80MSU0401712A* | 16.0 | 13.0 | 8.0 | 8,300 | 217722527 |
| EA*5X25M17A | *80MSU0601716A* | 16.0 | 13.0 | 8.0 | 8,400 | 217722535 |
| EA*5X25M17A*+WALLCON | *80CTL0701412B* | 16.0 | 13.0 | 8.0 | 8,400 | 217722551 |
| EA*5X25M17A | *80VTL0451412B* | 16.0 | 13.0 | 8.0 | 8,400 | 217722575 |
| EA*5X25M17A | *80VTL0701716B* | 16.0 | 13.0 | 8.0 | 8,400 | 217722583 |
| EA*5X19M17A*+WALLCON | *96CTN0801714B* | 16.0 | 13.0 | 8.0 | 8,300 | 217721758 |
| EA*5X25M17A*+WALLCON | *96CTN0801714B* | 16.0 | 13.0 | 8.0 | 8,300 | 217722752 |
| FM(C,U)5Z30**AL | - | 16.0 | 13.0 | 8.0 | 8,100 | 217726362 |
| EA*5X19M17A | *92MSN0601714A* | 16.0 | 13.0 | 8.0 | 8,400 | 217721620 |
| EA*5X19M17A | *92MSN0801716A* | 16.0 | 13.0 | 8.0 | 8,300 | 217721628 |
| EA*5X25M17A | *80MS(N,L)0451412A* | 16.0 | 13.0 | 8.0 | 8,400 | 217722447 |
| EA*5X25M17A | *80MS(N,L)0701412A* | 16.0 | 13.0 | 8.0 | 8,300 | 217722463 |
| EA*5X25M17A | *80MS(N,L)0701712A* | 16.0 | 13.0 | 8.0 | 8,400 | 217722471 |
| EA*5X25M17A | *80MS(N,L)0701716A* | 16.0 | 13.0 | 8.0 | 8,400 | 217722479 |
| EA*5X25M17A | *80MS(N,L)0901714A* | 16.0 | 13.0 | 8.0 | 8,300 | 217722487 |
| EA*5X25M17A | *80VSL0451412B* | 16.0 | 13.0 | 8.0 | 8,400 | 217722495 |
| EA*5X25M17A | *80VSL0701412B* | 16.0 | 13.0 | 8.0 | 8,400 | 217722503 |
| EA*5X25M17A | *80VSL0701716B* | 16.0 | 13.0 | 8.0 | 8,400 | 217722511 |
| EA*5X25M17A*+WALLCON | *97CMN0801714B* | 16.0 | 13.0 | 8.0 | 8,400 | 217722607 |
| EA*5X25M17A | *92MSN0601412A* | 16.0 | 13.0 | 8.0 | 8,300 | 217722623 |
| EA*5X25M17A | *92MSN0601714A* | 16.0 | 13.0 | 8.0 | 8,400 | 217722631 |
| EA*5X25M17A | *92MSN0801716A* | 16.0 | 13.0 | 8.0 | 8,300 | 217722639 |
| EA*5X25M17A | *95MSU0601716A* | 16.0 | 12.5 | 8.0 | 8,400 | 217722728 |
| EA*5X25M17A*+WALLCON | *80CSU0401712B* | 16.0 | 13.0 | 7.8 | 8,300 | 217722431 |
| EA*5X25M17A*+WALLCON | *80CSU0601716B* | 16.0 | 13.0 | 7.8 | 8,300 | 217722439 |
| EA*5X19M17A*+WALLCON | *80CSU0401712B* | 16.0 | 13.0 | 7.8 | 8,300 | 217721532 |
| EA*5X19M17A*+WALLCON | *80CSU0601716B* | 16.0 | 13.0 | 7.8 | 8,300 | 217721540 |
| EA*5X19M17A | *80MSU0401712A* | 16.0 | 13.0 | 7.8 | 8,300 | 217721548 |
| EA*5X19M17A | *80MSU0601716A* | 16.0 | 13.0 | 7.8 | 8,300 | 217721556 |
| EA*5X25M17A*+WALLCON | *80CTL0451712B* | 15.5 | 13.0 | 8.0 | 8,400 | 217722543 |
| EA*5X25M17A*+WALLCON | *80CTL0701716B* | 15.5 | 13.0 | 8.0 | 8,400 | 217722559 |
| EA*5X25M17A*+WALLCON | *80CTL0901716B* | 15.5 | 13.0 | 8.0 | 8,400 | 217722567 |
| EA*5X19M17A*+WALLCON | *96CTN0601714B* | 15.5 | 13.0 | 8.0 | 8,400 | 217721750 |
| EA*5X19M17A*+WALLCON | *97CTN0801716A* | 15.5 | 13.0 | 8.0 | 8,400 | 217721774 |
| EA*5X25M17A*+WALLCON | *96CTN0601714B* | 15.5 | 13.0 | 8.0 | 8,400 | 217722744 |
| EA*5X25M17A*+WALLCON | *97CTN0601716A* | 15.5 | 13.0 | 8.0 | 8,400 | 217722760 |
| EA*5X25M17A*+WALLCON | *97CTN0801716A* | 15.5 | 13.0 | 8.0 | 8,400 | 217722768 |
| EA*5X25M17A | *96VTN0601412B* | 15.5 | 13.0 | 8.0 | 8,400 | 217722792 |
| EA*5X25M17A | *96VTN0601716B* | 15.5 | 13.0 | 8.0 | 8,400 | 217722800 |
| EA*5X25M17A | *97VTN0601716A* | 15.5 | 13.0 | 8.0 | 8,400 | 217722808 |
| EA*5X25M17A | OMV098J12* | 15.5 | 13.0 | 8.0 | 8,300 | 217722824 |
| EA*5X19M17A | *80VTL0701716B* | 15.5 | 13.0 | 8.0 | 8,400 | 217721564 |
| EA*5X19M17A*+WALLCON | *97CMN0601714B* | 15.5 | 13.0 | 8.0 | 8,400 | 217721580 |
| EA*5X19M17A*+WALLCON | *97CMN0801714B* | 15.5 | 13.0 | 8.0 | 8,300 | 217721588 |
| EA*5X19M17A | *92MSN0601412A* | 15.5 | 13.0 | 8.0 | 8,300 | 217721612 |
| EA*5X19M17A | *96MSN0801716A* | 15.5 | 13.0 | 8.0 | 8,400 | 217721678 |
| EA*5X19M17A | *96VSN0601716B* | 15.5 | 13.0 | 8.0 | 8,400 | 217721710 |
| EA*5X19M17A | *96VSN0801716B* | 15.5 | 13.0 | 8.0 | 8,300 | 217721718 |
| EA*5X25M17A | *80MS(N,L)0451714A* | 15.5 | 13.0 | 8.0 | 8,400 | 217722455 |
| EA*5X19M17A | *96MSN0601412A* | 15.5 | 13.0 | 8.0 | 8,400 | 217721661 |
| EA*5X19M17A | *96VTN0601716B* | 15.5 | 13.0 | 8.0 | 8,400 | 217721806 |
| EA*5X19M17A | *96VTN0801716B* | 15.5 | 13.0 | 8.0 | 8,300 | 217721814 |
| EA*5X19M17A | *97VTN0601716A* | 15.5 | 13.0 | 8.0 | 8,400 | 217721822 |
| EA*5X19M17A | *97VTN0801716A* | 15.5 | 13.0 | 8.0 | 8,300 | 217721830 |
| EA*5X25M17A*+WALLCON | *97CMN0601714B* | 15.5 | 13.0 | 8.0 | 8,400 | 217722599 |
| EA*5X25M17A | *96MSN0261410A* | 15.5 | 13.0 | 8.0 | 8,400 | 217722647 |
| EA*5X25M17A | *96MSN0601412A* | 15.5 | 13.0 | 8.0 | 8,400 | 217722672 |
| EA*5X25M17A | *96MSN0801716A* | 15.5 | 13.0 | 8.0 | 8,500 | 217722680 |
| EA*5X25M17A | *96VSN0601412B* | 15.5 | 13.0 | 8.0 | 8,400 | 217722704 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the Tempstar T5H6S19*K*AAA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Kenmore (C,H,T)5H6S19*K*AAA
Yearly running cost in 10 large cities
- Phoenix, AZ$695/yr
- Miami, FL$561/yr
- Houston, TX$623/yr
- Atlanta, GA$636/yr
- Los Angeles, CA$620/yr
- New York, NY$1,526/yr
- Chicago, IL$1,240/yr
- Denver, CO$1,032/yr
- Seattle, WA$635/yr
- Minneapolis, MN$1,277/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Tempstar T5H6S19*K*AAA?
- The Tempstar T5H6S19*K*AAA is rated at up to 16.0 SEER2 and 13.0 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 76 certified matchups SEER2 ranges from 15.2-16.0.
- Is the Tempstar T5H6S19*K*AAA good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
- How much does the Tempstar T5H6S19*K*AAA cost to run per year?
- At its rated efficiency it costs about $561-$1,526 a year in electricity in large U.S. cities, depending on climate and local rates - for example $695 in Phoenix and $1,277 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Tempstar T5H6S19*K*AAA the same as the Kenmore (C,H,T)5H6S19*K*AAA?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the Tempstar T5H6S19*K*AAA?
- ENERGY STAR lists 76 certified combinations for this outdoor unit. The highest-rated ones use EA*5X25M17A, EA*5X25M17A*+WALLCON, EA*5X19M17A*+WALLCON.
- What refrigerant does the Tempstar T5H6S19*K*AAA use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 1.5 ton models
- Luxaire XH618E2S1116.0 SEER2 · 8.0 HSPF2
- WeatherMaker PH5SAN519**AB16.0 SEER2 · 8.0 HSPF2
- Heil H5H6S19*K*AAA16.0 SEER2 · 8.0 HSPF2
- York YH618E2S1116.0 SEER2 · 8.0 HSPF2
- Heil B5H6S19*K*AAA16.0 SEER2 · 8.0 HSPF2
- Coleman XH518E2S1116.0 SEER2 · 7.8 HSPF2
- ECOTEMP W5H5S19*K*AAA16.0 SEER2 · 8.0 HSPF2
- Friedrich FWP15AY18AJ2N16.0 SEER2 · 7.8 HSPF2
See all 170 1.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 17, 2026. How we use the data.