HVAC Rated

1.5-ton central heat pump · 15 SEER2 HP

WeatherMaker PH5SAN519**AB

Below average cooling and heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.

Ranks #134 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $636 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.0 Heating efficiency over a season
Below average · beats 12%
EER2
12.5 Cooling efficiency on a 95°F day
Very good · beats 80%
Heat at 5°F
8,500 BTU/h43% of its 47°F output
Below average · beats 39%

A good fit if…

  • You want a choice of indoor units - 50 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications1.5 ton, R-454B
General
BrandWeatherMaker
Outdoor unit modelPH5SAN519**AB
Series15 SEER2 HP
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJuly 31, 2025
Last certifiedSeptember 22, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors12.5-13.0
Cooling capacity17,700-19,300 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.0
Capacity at 47°F18,400-19,500 BTU/h
Capacity at 17°F10,300-11,000 BTU/h
Capacity at 5°F7,900-8,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.00
ENERGY STAR cold climateNo
Heating output as it gets colder43% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CAA**2517AM at the standard test temperatures, in BTU/h:

Certified matchups50 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CAA**2517AMPG95MSUA48060B**16.012.58.08,400218754494
CAA**2517AMPG92MSAA48080B**16.013.08.08,300218754487
CAA**2517AMPG92MSAA42060B**16.013.08.08,400218754486
CAA**2517AMPG92MSAA36060A**16.013.08.08,300218754485
CAA**2517AMPG80VTLB48090B**16.013.08.08,400218754483
CAA**2517AMPG80VTLB48070B**16.013.08.08,400218754482
CAA**2517AMPG80VTLB36070A**16.013.08.08,400218754481
CAA**2517AMPG80VTLB36045A**16.013.08.08,400218754480
CAA**2517AMPG80MSUA48060B**16.013.08.08,400218754479
CAA**2517AMPG80MSUA36040B**16.013.08.08,300218754478
CAA**2517AMPG80MS(A,L)A42090B**16.013.08.08,300218754477
CAA**2517AMPG80MS(A,L)A48070B**16.013.08.08,400218754476
CAA**2517AMPG80MS(A,L)A36070B**16.013.08.08,400218754475
CAA**2517AMPG80MS(A,L)A36070A**16.013.08.08,300218754474
CAA**2517AMPG80MS(A,L)A36045A**16.013.08.08,400218754472
CAA**1917AMPG92MSAA48080B**16.013.08.08,300218754414
CAA**1917AMPG92MSAA42060B**16.013.08.08,400218754413
FM(C,U)5Z30**AL-16.013.08.08,100218754082
CAA**1917AMPG80MSUA48060B**16.013.07.88,300218754407
CAA**1917AMPG80MSUA36040B**16.013.07.88,300218754406
CAA**2517AMPG97VTAA48060B**15.513.08.08,400218754499
CAA**2517AMPG96VTAB48060B**15.513.08.08,400218754498
CAA**2517AMPG96VTAB36060A**15.513.08.08,400218754497
CAA**2517AMPG96MSAA48080B**15.513.08.08,500218754492
CAA**2517AMPG96MSAA36060A**15.513.08.08,400218754491
CAA**2517AMPG96MSAA30026A**15.513.08.08,400218754488
CAA**2517AMPG80MS(A,L)A42045B**15.513.08.08,400218754473
CAA**1917AMPG97VTAA48080B**15.513.08.08,300218754429
CAA**1917AMPG97VTAA48060B**15.513.08.08,400218754428
CAA**1917AMPG96VTAB48080B**15.513.08.08,300218754427
CAA**1917AMPG96VTAB48060B**15.513.08.08,400218754426
CAA**1917AMPG96MSAA48080B**15.513.08.08,400218754420
CAA**1917AMPG96MSAA36060A**15.513.08.08,400218754418
CAA**1917AMPG92MSAA36060A**15.513.08.08,300218754412
CAA**1917AMPG80VTLB48090B**15.513.08.08,300218754409
CAA**1917AMPG80VTLB48070B**15.513.08.08,400218754408
FM(C,U)5S24**AL-15.512.57.88,100218754758
FM(C,U)5S18**AL-15.512.57.88,100218754757
FJ5AN*B24L-15.513.07.88,000218754748
CAA**2517AMPG95MSUA36040B**15.512.57.88,400218754493
CAA**1917AMPG95MSUA48060B**15.512.57.88,400218754422
PF5TNXB24L-15.513.07.88,100218754087
FMA5X24**AL-15.513.07.87,900218754086
FMA5X18**AL-15.513.07.87,900218754085
FM(C,U)5Z24**AL-15.513.07.88,100218754081
FM(C,U)5Z18**AL-15.513.07.88,100218754080
PF5MN*B24L-15.513.07.88,000218754077
FJ5AN*A18L-15.212.57.88,100218754750
FMA5L18**AL-15.212.57.88,400218754083
PF5MN*A18L-15.212.57.88,100218754076
Yearly running cost in 10 large cities$561-$1,526

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the WeatherMaker PH5SAN519**AB?
The WeatherMaker PH5SAN519**AB is rated at up to 16.0 SEER2 and 12.5 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 50 certified matchups SEER2 ranges from 15.2-16.0.
Is the WeatherMaker PH5SAN519**AB good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
How much does the WeatherMaker PH5SAN519**AB cost to run per year?
At its rated efficiency it costs about $561-$1,526 a year in electricity in large U.S. cities, depending on climate and local rates - for example $695 in Phoenix and $1,277 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the WeatherMaker PH5SAN519**AB?
ENERGY STAR lists 50 certified combinations for this outdoor unit. The highest-rated ones use CAA**2517AM, CAA**1917AM, FM(C,U)5Z30**AL.
What refrigerant does the WeatherMaker PH5SAN519**AB use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $692/yrYou save $298/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump WeatherMaker PH5SAN519**AB
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$692
Current system, per year
$990
You save per year
$298
Payback
23.5 years
Net after 10 years
-$4,020

Cooling $420Heating $272Electricity used: 4,324 kWhSaved vs. a minimum-efficiency heat pump: $68

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 22, 2026. How we use the data.