HVAC Rated

5-ton central heat pump · Performance 19 SEER2 VS HP

Airquest N5H9V60*K*AAA

Average cooling and heating efficiency for a 5-ton central heat pump, and certified for cold climates.

Ranks #20 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,699 a year to run in a mixed climate like Atlanta.

SEER2
17.5 Cooling efficiency over a season
Average · beats 58%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
42,000 BTU/h71% of its 47°F output
Very good · beats 70%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 42,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 1,696 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications5 ton, R-454B
General
BrandAirquest
Also sold asKeeprite, Arcoaire, Comfortmaker, Day & Night, Heil, Tempstar, ACIQ
Outdoor unit modelN5H9V60*K*AAA
SeriesPerformance 19 SEER2 VS HP
TypeCentral heat pump
Nominal size5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 14, 2025
Last certifiedOctober 7, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.5 (range 15.2-17.5)
EER2Efficiency at 95°F outdoors10.0-12.0
Cooling capacity54,000-57,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.0-9.0
Capacity at 47°F56,500-62,000 BTU/h
Capacity at 17°F48,000-50,500 BTU/h
Capacity at 5°F39,000-42,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.94-2.16
ENERGY STAR cold climateYes
Heating output as it gets colder71% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with QFVA5D6021X at the standard test temperatures, in BTU/h:

Certified matchups1,696 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 1,696 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
QFVA5D6021X · cold climate-17.512.08.140,000218695583
QFVA5D6021X · cold climate-17.512.08.140,000218695581
QFVA5D6021X · cold climate-17.512.08.140,000218695579
QFVA5D6021X · cold climate-17.512.08.140,000218695577
QFVA5D6021X · cold climate-17.512.08.140,000218695575
QFVA5D6021X · cold climate-17.512.08.140,000218695573
QFVA5D6021X · cold climate-17.512.08.140,000218695571
QFVA5D6021X · cold climate-17.512.08.140,000218822098
FTMA5B60L0D · cold climate-17.012.09.041,000217918385
FTMA5B60L0D · cold climate-17.012.09.041,000217918386
FTMA5B60L0D · cold climate-17.012.09.041,000217918387
FTMA5B60L0D · cold climate-17.012.09.041,000217918388
FTMA5B60L0D · cold climate-17.012.09.041,000217918389
FTMA5B60L0D · cold climate-17.012.09.041,000217918390
FTMA5B60L0D · cold climate-17.012.09.041,000217918391
FTMA5B60L0D · cold climate-17.012.09.041,000218017577
EA*5X61M24A*80MSU0802120A*16.511.08.540,500217932514
EA*5X61M24A*80MSU0802120A*16.511.08.540,500217932515
EA*5X61M24A*80MSU0802120A*16.511.08.540,500217932516
EA*5X61M24A*80MSU0802120A*16.511.08.540,500217932517
EA*5X61M24A*80MSU0802120A*16.511.08.540,500217932518
EA*5X61M24A*80MSU0802120A*16.511.08.540,500217932519
EA*5X61M24A*80MSU0802120A*16.511.08.540,500217932520
EA*5X61M24A*80CSU0802120B*16.511.08.540,500217932443
EA*5X61M24A*80CSU0802120B*16.511.08.540,500217932439
EA*5X61M24A*80CSU0802120B*16.511.08.540,500217932440
EA*5X61M24A*80CSU0802120B*16.511.08.540,500217932441
EA*5X61M24A*80CSU0802120B*16.511.08.540,500217932442
EA*5X61M24A*80CSU0802120B*16.511.08.540,500217932444
EA*5X61M24A*80CSU0802120B*16.511.08.540,500217932445
EA*5X61M24A*80CSU0802120B*16.511.08.540,500218018622
EA*5X61M24A*80MSU0802120A*16.511.08.540,500218018650
EA*5X61M24A*80VSL1352422B*16.011.09.040,500217932504
EA*5X61M24A*80VSL1352422B*16.011.09.040,500217932505
EA*5X61M24A · cold climate*80CTL0902120B*16.011.09.041,000217932559
EA*5X61M21A · cold climate*96VTN1002120B*16.011.09.041,000217932364
EA*5X61M21A · cold climate*96VTN1002120B*16.011.09.041,000217932365
EA*5X61M21A · cold climate*96VTN1002120B*16.011.09.041,000217932366
EA*5X61M21A · cold climate*96VTN1002120B*16.011.09.041,000217932367
EA*5X61M21A · cold climate*80VSL0902120B*16.011.09.041,000217932035
EA*5X61M21A · cold climate*80VSL0902120B*16.011.09.041,000217932034
EA*5X61M21A · cold climate*80VSL0902120B*16.011.09.041,000217932036
EA*5X61M21A · cold climate*80VSL0902120B*16.011.09.041,000217932038
EA*5X61M21A · cold climate*80VSL0902120B*16.011.09.041,000217932039
EA*5X61M21A · cold climate*80VSL0902120B*16.011.09.041,000217932040
EA*5X61M21A · cold climate*80VSL0902120B*16.011.09.041,000217932037
EA*5X60M24A · cold climateOLV154F20A16.011.09.041,000217931989
EA*5X61M21A · cold climate*80VSL1102122B*16.011.09.041,000217932049
EA*5X61M21A · cold climate*80VSL1102122B*16.011.09.041,000217932050
EA*5X61M21A · cold climate*80VSL1102122B*16.011.09.041,000217932051
EA*5X61M21A · cold climate*80VSL1102122B*16.011.09.041,000217932052
EA*5X61M21A · cold climate*80VSL1102122B*16.011.09.041,000217932053
EA*5X60M24A · cold climate*97CTN1202422A*16.011.09.040,500217931854
EA*5X60M24A · cold climate*97CTN1202422A*16.011.09.040,500217931855
EA*5X60M24A · cold climate*97CTN1202422A*16.011.09.040,500217931856
EA*5X60M24A · cold climate*97CTN1202422A*16.011.09.040,500217931857
EA*5X60M24A · cold climate*97CTN1202422A*16.011.09.040,500217931858
EA*5X60M24A · cold climate*97CTN1202422A*16.011.09.040,500217931859
EA*5X60M24A · cold climate*97CTN1202422A*16.011.09.040,500217931860
EA*5X61M21A · cold climate*80VSL1102122B*16.011.09.041,000217932054
Yearly running cost in 10 large cities$1,492-$4,083

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Airquest N5H9V60*K*AAA?
The Airquest N5H9V60*K*AAA is rated at up to 17.5 SEER2 and 12.0 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 1696 certified matchups SEER2 ranges from 15.2-17.5.
Is the Airquest N5H9V60*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 42,000 BTU/h at 5°F with a COP of 2.16, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
How much does the Airquest N5H9V60*K*AAA cost to run per year?
At its rated efficiency it costs about $1,492-$4,083 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,852 in Phoenix and $3,421 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Airquest N5H9V60*K*AAA?
ENERGY STAR lists 1696 certified combinations for this outdoor unit. The highest-rated ones use QFVA5D6021X, FTMA5B60L0D, EA*5X61M24A.
What refrigerant does the Airquest N5H9V60*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,844/yrYou save $1,066/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Airquest N5H9V60*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,844
Current system, per year
$2,911
You save per year
$1,066
Payback
19.7 years
Net after 10 years
-$10,335

Cooling $1,116Heating $728Electricity used: 11,527 kWhSaved vs. a minimum-efficiency heat pump: $395

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 5 ton models

See all 100 5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 7, 2026. How we use the data.