HVAC Rated

5-ton central heat pump · Preferred 19 SEER2 VS HP

Bryant 249VAN060**AA

Average cooling and heating efficiency for a 5-ton central heat pump, and certified for cold climates.

Ranks #21 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,699 a year to run in a mixed climate like Atlanta.

SEER2
17.5 Cooling efficiency over a season
Average · beats 58%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
42,000 BTU/h71% of its 47°F output
Very good · beats 70%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 42,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 218 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications5 ton, R-454B
General
BrandBryant
Outdoor unit model249VAN060**AA
SeriesPreferred 19 SEER2 VS HP
TypeCentral heat pump
Nominal size5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 15, 2025
Last certifiedSeptember 30, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.5 (range 15.2-17.5)
EER2Efficiency at 95°F outdoors10.0-12.0
Cooling capacity54,000-57,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.0-9.0
Capacity at 47°F56,500-62,000 BTU/h
Capacity at 17°F48,000-50,500 BTU/h
Capacity at 5°F39,000-42,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.94-2.16
ENERGY STAR cold climateYes
Heating output as it gets colder71% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FT5BD6021X at the standard test temperatures, in BTU/h:

Certified matchups218 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 218 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FT5BD6021X · cold climate-17.512.08.140,000218695570
FT5ANBD60L · cold climate-17.012.09.041,000217918382
FG5ANBD60L · cold climate-17.012.09.041,000217918383
PF5TNBD60L · cold climate-17.012.09.041,000217918384
CAA**6124AM83*SB60080M21***16.511.08.540,500217932513
CAA**6124AM83*CB60080C21***16.511.08.540,500217932438
CAA**6124AM · cold climate88*TB60090C21***16.011.09.041,000217932558
CAA**6121AM · cold climate926TC60100V21***16.011.09.041,000217932363
CAA**6121AM · cold climate82*SB60090V21***16.011.09.041,000217932033
CAA**6024AM · cold climateOVLAAB06015416.011.09.041,000217931988
CAA**6121AM · cold climate82*SB66110V21***16.011.09.041,000217932048
CAA**6024AM · cold climate987TA66120C24***16.011.09.040,500217931853
CAA**6024AM · cold climate82*SB66110V21***16.011.09.040,500217931507
CAA**6124AM · cold climate926SB60100V21***16.011.09.041,000217932709
CAA**6124AM926SB66120V24***16.011.09.040,500217932724
CAA**6121AM · cold climate82*TB60090V21***16.011.09.041,000217932138
CAA**6121AM82*TB66110V21***16.011.09.040,500217932153
CAA**6121AM · cold climate88*TB60110C21***16.011.09.041,000217932123
CAA**6024AM926TC66100V21***16.011.09.040,000217931898
CAA**6124AM · cold climate986TD66100C21***16.011.09.041,000217932799
CAA**6124AM986TD66120C24***16.011.09.040,500217932814
CAA**6024AM82*SB66135V24***16.011.09.040,000217931522
CAA**6024AM · cold climate82*SB60090V21***16.011.09.040,500217931492
CAA**6024AM · cold climate82*TB66110V21***16.011.09.040,500217931627
CAA**6024AM927TA66100V21***16.011.09.040,000217931958
CAA**6124AM · cold climate88*TB60110C21***16.011.09.041,000217932573
CAA**6124AM · cold climate88*TB66135C24***16.011.09.041,000217932588
CAA**6124AM · cold climate82*TB60090V21***16.011.09.041,000217932603
CAA**6024AM · cold climate986TD66120C24***16.011.09.040,500217931808
CAA**6024AM88*TB60090C21***16.011.09.040,500217931567
CAA**6024AM88*TB60110C21***16.011.09.040,500217931582
F55AA*D60L-16.011.79.040,000217933355
CAA**6124AM82*TB66110V21***16.011.09.040,500217932618
CAA**6124AM82*TB66135V24***16.011.09.040,500217932633
CAA**6124AM · cold climate987MC66100C21***16.011.09.041,000217932664
CAA**6124AM987TA66120C24***16.011.09.040,500217932859
CAA**6124AM · cold climate987TA66100C21***16.011.09.041,000217932844
CAA**6024AM · cold climate82*TB60090V21***16.011.09.040,500217931612
CAA**6124AM · cold climate926TC60100V21***16.011.09.041,000217932889
CAA**6024AM88*TB66135C24***16.011.09.040,500217931597
CAA**6024AM82*TB66135V24***16.011.09.040,000217931642
CAA**6124AM · cold climate927TA60100V21***16.011.09.041,000217932949
CAA**6124AM926TC66100V21***16.011.09.040,500217932904
CAA**6124AM · cold climate926TC66120V24***16.011.09.041,000217932919
CAA**6124AM · cold climateOVLAAB06015416.011.09.041,000217932994
CAA**6124AM · cold climate82*SB60090V21***16.011.09.041,000217932468
CAA**6124AM82*SB66110V21***16.011.09.040,500217932483
CAA**6124AM82*SB66135V24***16.011.09.040,500217932498
CAA**6124AM927TA66100V21***16.011.09.040,500217932964
CAA**6124AM · cold climate927TA66120V24***16.011.09.041,000217932979
CAA**6024AM987MC66100C21***16.011.09.040,500217931688
CAA**6121AM · cold climate926TC66100V21***16.011.09.041,000217932378
CAA**6121AM · cold climate927TA60100V21***16.011.09.041,000217932408
CAA**6121AM · cold climate927TA66100V21***16.011.09.041,000217932423
CAA**6024AM · cold climate987MC66120C24***16.010.59.041,000217953370
CAA**6124AM · cold climate83*SB60100M21***16.011.08.541,000217932528
CAA**6124AM · cold climate88*TB60070C21***16.011.08.541,000217932543
CAA**6121AM · cold climate987TA66100C21***16.011.08.541,000217932333
CAA**6121AM · cold climate935SB66100M21***16.011.08.541,000217932273
CAA**6121AM83*SB60080M21***16.011.08.540,500217932078
Yearly running cost in 10 large cities$1,492-$4,083

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Bryant 249VAN060**AA?
The Bryant 249VAN060**AA is rated at up to 17.5 SEER2 and 12.0 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 218 certified matchups SEER2 ranges from 15.2-17.5.
Is the Bryant 249VAN060**AA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 42,000 BTU/h at 5°F with a COP of 2.16, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
How much does the Bryant 249VAN060**AA cost to run per year?
At its rated efficiency it costs about $1,492-$4,083 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,852 in Phoenix and $3,421 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Bryant 249VAN060**AA?
ENERGY STAR lists 218 certified combinations for this outdoor unit. The highest-rated ones use FT5BD6021X, FT5ANBD60L, FG5ANBD60L.
What refrigerant does the Bryant 249VAN060**AA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,844/yrYou save $1,066/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Bryant 249VAN060**AA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,844
Current system, per year
$2,911
You save per year
$1,066
Payback
19.7 years
Net after 10 years
-$10,335

Cooling $1,116Heating $728Electricity used: 11,527 kWhSaved vs. a minimum-efficiency heat pump: $395

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 5 ton models

See all 100 5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.