5-ton central heat pump · T32
Innovair TOV60H2XA
Very good cooling efficiency and average heating efficiency for a 5-ton central heat pump, and certified for cold climates.
Ranks #19 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,573 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.5 Cooling efficiency over a seasonVery good · beats 77%
- HSPF2
- 9.2 Heating efficiency over a seasonAverage · beats 61%
- EER2
- 11.5 Cooling efficiency on a 95°F dayBelow average · beats 31%
- Heat at 5°F
- 40,000 BTU/h72% of its 47°F outputVery good · beats 88%
A good fit if…
- You want low cooling bills - its SEER2 beats 77% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 40,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Innovair |
| Also sold as | Emeric |
| Outdoor unit model | TOV60H2XA |
| Series | T32 |
| Type | Central heat pump |
| Nominal size | 5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | September 29, 2026 |
| Last certified | September 30, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.5 (range 18.0-18.5) |
| EER2Efficiency at 95°F outdoors | 10.0-11.5 |
| Cooling capacity | 47,000-55,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.8-9.2 |
| Capacity at 47°F | 47,000-55,000 BTU/h |
| Capacity at 17°F | 30,400-35,000 BTU/h |
| Capacity at 5°F | 34,000-40,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.30 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TAV48X2A at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| TAV48X2A · cold climate | 18.5 | 11.5 | 9.2 | 34,000 | 217496786 |
| TAV60X2A · cold climate | 18.0 | 10.0 | 8.8 | 40,000 | 217496787 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the Innovair TOV60H2XA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Emeric ETD-H60DMR3
Yearly running cost in 10 large cities
- Phoenix, AZ$1,727/yr
- Miami, FL$1,398/yr
- Houston, TX$1,548/yr
- Atlanta, GA$1,573/yr
- Los Angeles, CA$1,533/yr
- New York, NY$3,768/yr
- Chicago, IL$3,061/yr
- Denver, CO$2,546/yr
- Seattle, WA$1,566/yr
- Minneapolis, MN$3,152/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Innovair TOV60H2XA?
- The Innovair TOV60H2XA is rated at up to 18.5 SEER2 and 11.5 EER2 for cooling and up to 9.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 2 certified matchups SEER2 ranges from 18.0-18.5.
- Is the Innovair TOV60H2XA good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 40,000 BTU/h at 5°F with a COP of 2.30, so it is still 2.3 times as efficient as electric resistance heat at that temperature.
- How much does the Innovair TOV60H2XA cost to run per year?
- At its rated efficiency it costs about $1,398-$3,768 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,727 in Phoenix and $3,152 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Innovair TOV60H2XA the same as the Emeric ETD-H60DMR3?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the Innovair TOV60H2XA?
- ENERGY STAR lists 2 certified combinations for this outdoor unit. The highest-rated ones use TAV48X2A, TAV60X2A.
- What refrigerant does the Innovair TOV60H2XA use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 5 ton models
- Friedrich RD17AZ60AJ3N · cold climate19.0 SEER2 · 8.1 HSPF2
- Airquest N5H9V60*K*AAA · cold climate17.5 SEER2 · 9.0 HSPF2
- GE NS22H60MA4-**A19.0 SEER2 · 8.7 HSPF2
- Bryant 249VAN060**AA · cold climate17.5 SEER2 · 9.0 HSPF2
- Armstrong Air 4SHP22LX160P-**A19.0 SEER2 · 8.7 HSPF2
- Carrier 27VPA960A*030 · cold climate17.5 SEER2 · 9.0 HSPF2
- Multi MFG MSD-60HD-B · cold climate19.0 SEER2 · 9.0 HSPF2
- Keeprite C5H0V60*K*AAA · cold climate19.0 SEER2 · 9.0 HSPF2
See all 100 5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.