3-ton central heat pump · Platinum 19
American Standard 4A6L9036A1
Average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.
Ranks #113 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,042 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.0 Cooling efficiency over a seasonAverage · beats 66%
- HSPF2
- 8.7 Heating efficiency over a seasonAverage · beats 47%
- EER2
- 12.0 Cooling efficiency on a 95°F dayAverage · beats 64%
- Heat at 5°F
- - Not reported by the maker
A good fit if…
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 10 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | American Standard |
| Outdoor unit model | 4A6L9036A1 |
| Series | Platinum 19 |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 1, 2023 |
| Last certified | May 3, 2023 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.0 (range 17.5-18.0) |
| EER2Efficiency at 95°F outdoors | 11.7-12.0 |
| Cooling capacity | 37,400-38,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.5-8.7 |
| Capacity at 47°F | 33,000-33,600 BTU/h |
| Capacity at 17°F | 23,000-23,600 BTU/h |
| Capacity at 5°F | - |
| COP at 5°F2.0 = twice as efficient as a space heater | - |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 4TXCD010DS3 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 4TXCD010DS3 | S8V2D120M5PCA | 18.0 | 12.0 | 8.7 | - | 210691978 |
| 4PX*DU60BS3 | S8V2D120M5PCA | 18.0 | 12.0 | 8.7 | - | 210691964 |
| 4TXCC009DS3 | S8V2C100M5PCA | 17.5 | 11.7 | 8.7 | - | 210691976 |
| 4PX*CU60BS3 | S8V2C100M5PCA | 17.5 | 11.7 | 8.7 | - | 210691961 |
| 4PX*DU48BS3 | S8V2D120M5PCA | 17.5 | 11.7 | 8.7 | - | 210691963 |
| 4TXCD008DS3 | S8V2D120M5PCA | 17.5 | 11.7 | 8.7 | - | 210691977 |
| 4TXCC009DS3 | S8V2C080M5PCA | 17.5 | 11.7 | 8.7 | - | 210691975 |
| 4PX*CU60BS3 | S8V2C080M5PCA | 17.5 | 11.7 | 8.7 | - | 210691960 |
| 4PX*CD60BS3 | S8V2C100M5PCA | 17.5 | 11.7 | 8.5 | - | 210691953 |
| 4PX*CD60BS3 | S8V2C080M5PCA | 17.5 | 11.7 | 8.5 | - | 210691952 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,184/yr
- Miami, FL$979/yr
- Houston, TX$1,060/yr
- Atlanta, GA$1,042/yr
- Los Angeles, CA$1,007/yr
- New York, NY$2,452/yr
- Chicago, IL$1,983/yr
- Denver, CO$1,643/yr
- Seattle, WA$1,005/yr
- Minneapolis, MN$2,031/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the American Standard 4A6L9036A1?
- The American Standard 4A6L9036A1 is rated at up to 18.0 SEER2 and 12.0 EER2 for cooling and up to 8.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 10 certified matchups SEER2 ranges from 17.5-18.0.
- Is the American Standard 4A6L9036A1 good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
- How much does the American Standard 4A6L9036A1 cost to run per year?
- At its rated efficiency it costs about $979-$2,452 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,184 in Phoenix and $2,031 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the American Standard 4A6L9036A1?
- ENERGY STAR lists 10 certified combinations for this outdoor unit. The highest-rated ones use 4TXCD010DS3, 4PX*DU60BS3, 4TXCC009DS3.
- What refrigerant does the American Standard 4A6L9036A1 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- VillaTherm VHPSD-UCHA-36HDCSN4 · cold climate18.0 SEER2 · 9.0 HSPF2
- Trane 4TWL9036A118.0 SEER2 · 8.7 HSPF2
- VillaTherm VHPSD-UCHA-36HDCSN · cold climate18.0 SEER2 · 9.0 HSPF2
- UTL UCHA-36HDCSN4 · cold climate18.0 SEER2 · 9.0 HSPF2
- Trane 4TWV8X36A118.0 SEER2 · 8.5 HSPF2
- UTL UCHA-36HDCSN2 · cold climate18.0 SEER2 · 9.0 HSPF2
- ApooDr AHU3G-36HFN-B · cold climate17.7 SEER2 · 10.0 HSPF2
- Tempstar Q5H9V36*K*AAA · cold climate18.0 SEER2 · 9.0 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 3, 2023. How we use the data.