36,000 BTU mini-split heat pump · BMS Series
Blueridge BMS36HHUYC
Below average cooling efficiency and very good heating efficiency for a 36,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #102 of 205 36,000 BTU mini-splits for cooling efficiency, and costs about $904 a year to run in a mixed climate like Atlanta.
- SEER2
- 21.2 Cooling efficiency over a seasonBelow average · beats 35%
- HSPF2
- 11.1 Heating efficiency over a seasonVery good · beats 78%
- EER2
- 12.0 Cooling efficiency on a 95°F dayBelow average · beats 25%
- Heat at 5°F
- 39,500 BTU/h100% of its 47°F outputAverage · beats 67%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 39,500 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 78% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
Details
Specifications
| General | |
|---|---|
| Brand | Blueridge |
| Also sold as | Innovair, TRUST AIR CONDITIONERS, SLIMAIR, DIRECT AIR, CanAir, Multi MFG |
| Outdoor unit model | BMS36HHUYC |
| Series | BMS Series |
| Type | Mini-split heat pump |
| Nominal size | 36,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 1, 2024 |
| Last certified | March 4, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 21.2 (range 17.7-21.2) |
| EER2Efficiency at 95°F outdoors | 12.0 |
| Cooling capacity | 36,000-36,600 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.6-11.1 |
| Capacity at 47°F | 37,000-42,000 BTU/h |
| Capacity at 17°F | 30,200-31,600 BTU/h |
| Capacity at 5°F | 37,000-39,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.95-2.10 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BMS36CC at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| BMS36CC BLUERIDGE · cold climate | 21.2 | 12.0 | 10.6 | 37,000 | 215853959 |
| BMS36FCC BLUERIDGE · cold climate | 20.0 | 12.0 | 10.8 | 39,500 | 215853964 |
| BMS36HCD BLUERIDGE · cold climate | 17.7 | 12.0 | 11.1 | 37,600 | 215853961 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the Blueridge BMS36HHUYC: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Blueridge BXL2A36UC0
- Innovair MOS36H2BH0A
- TRUST AIR CONDITIONERS OAH36H/O6S4P
- SLIMAIR SHC36AH2AG
- DIRECT AIR DIRM4-36LCHX-1Z
- CanAir 4C28LCH36H21
- Multi MFG MSH-36HD-B
Yearly running cost in 10 large cities
- Phoenix, AZ$995/yr
- Miami, FL$807/yr
- Houston, TX$892/yr
- Atlanta, GA$904/yr
- Los Angeles, CA$880/yr
- New York, NY$2,161/yr
- Chicago, IL$1,755/yr
- Denver, CO$1,459/yr
- Seattle, WA$897/yr
- Minneapolis, MN$1,806/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Blueridge BMS36HHUYC?
- The Blueridge BMS36HHUYC is rated at up to 21.2 SEER2 and 12.0 EER2 for cooling and up to 11.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 17.7-21.2.
- Is the Blueridge BMS36HHUYC good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 39,500 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
- How much does the Blueridge BMS36HHUYC cost to run per year?
- At its rated efficiency it costs about $807-$2,161 a year in electricity in large U.S. cities, depending on climate and local rates - for example $995 in Phoenix and $1,806 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Blueridge BMS36HHUYC the same as the Blueridge BXL2A36UC0?
- Yes, as far as the certified ratings go. ENERGY STAR lists 8 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the Blueridge BMS36HHUYC?
- ENERGY STAR lists 3 certified combinations for this outdoor unit. The highest-rated ones use BLUERIDGE BMS36CC, BLUERIDGE BMS36FCC, BLUERIDGE BMS36HCD.
- What refrigerant does the Blueridge BMS36HHUYC use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 36,000 BTU models
- 1HVAC ACIQ-36ZPL-HP230C · cold climate21.2 SEER2 · 11.1 HSPF2
- ECO-AIR EDSO-36H · cold climate21.2 SEER2 · 11.1 HSPF2
- Fujitsu AOUH36KUAS1 · cold climate21.3 SEER2 · 10.5 HSPF2
- Mainline ML36HP230LCMH-O · cold climate21.2 SEER2 · 11.1 HSPF2
- MDV MOX630-36HFN10-M2X · cold climate21.3 SEER2 · 11.1 HSPF2
- Midea MO1HU-H36B-2A · cold climate21.2 SEER2 · 11.1 HSPF2
- Carrier 37MBHAQ36AA3 · cold climate21.3 SEER2 · 11.1 HSPF2
- Sea Breeze CSZ36H525ZMO · cold climate21.2 SEER2 · 10.8 HSPF2
See all 205 36,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 4, 2025. How we use the data.