3-ton central heat pump · BZ33 series
Breeze33 BZ33-INV36OUT2-J
Average cooling efficiency and very good heating efficiency for a 3-ton central heat pump, and certified for cold climates.
Ranks #123 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,020 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.6 Cooling efficiency over a seasonAverage · beats 62%
- HSPF2
- 10.0 Heating efficiency over a seasonVery good · beats 84%
- EER2
- 10.2 Cooling efficiency on a 95°F dayBelow average · beats 15%
- Heat at 5°F
- 33,400 BTU/h88% of its 47°F outputBelow average · beats 39%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 33,400 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Breeze33 |
| Outdoor unit model | BZ33-INV36OUT2-J |
| Series | BZ33 series |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | November 1, 2023 |
| Last certified | June 9, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.6 (range 15.2-17.6) |
| EER2Efficiency at 95°F outdoors | 10.0-10.2 |
| Cooling capacity | 35,000-36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.6-10.0 |
| Capacity at 47°F | 38,000-39,000 BTU/h |
| Capacity at 17°F | 27,400-33,000 BTU/h |
| Capacity at 5°F | 31,600-33,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.81-2.00 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BZ33-WMAHU36-J at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| BZ33-WMAHU36-J · cold climate | 17.6 | 10.2 | 9.2 | 33,400 | 214391156 |
| BZ33-MSC36B-J · cold climate | 15.5 | 10.0 | 8.6 | 31,600 | 213732641 |
| BZ33-MSC36C-J · cold climate | 15.2 | 10.0 | 10.0 | 32,000 | 213732642 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,140/yr
- Miami, FL$933/yr
- Houston, TX$1,021/yr
- Atlanta, GA$1,020/yr
- Los Angeles, CA$989/yr
- New York, NY$2,419/yr
- Chicago, IL$1,961/yr
- Denver, CO$1,627/yr
- Seattle, WA$998/yr
- Minneapolis, MN$2,013/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Breeze33 BZ33-INV36OUT2-J?
- The Breeze33 BZ33-INV36OUT2-J is rated at up to 17.6 SEER2 and 10.2 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 15.2-17.6.
- Is the Breeze33 BZ33-INV36OUT2-J good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 33,400 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Breeze33 BZ33-INV36OUT2-J cost to run per year?
- At its rated efficiency it costs about $933-$2,419 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,140 in Phoenix and $2,013 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Breeze33 BZ33-INV36OUT2-J?
- ENERGY STAR lists 3 certified combinations for this outdoor unit. The highest-rated ones use BZ33-WMAHU36-J, BZ33-MSC36B-J, BZ33-MSC36C-J.
- What refrigerant does the Breeze33 BZ33-INV36OUT2-J use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- Mitsutomo UHO36-NB-LD-Q · cold climate17.7 SEER2 · 10.0 HSPF2
- DIYCOOL ACIQ-36-HPB · cold climate17.6 SEER2 · 10.0 HSPF2
- Midea MO1HE-H36B-2A · cold climate17.7 SEER2 · 10.0 HSPF2
- Innovair SHV36H2R20 · cold climate17.6 SEER2 · 10.0 HSPF2
- MDV MOD30-36HFN10-M3X · cold climate17.7 SEER2 · 10.0 HSPF2
- MDV MOE31U-36HFN1-M · cold climate17.6 SEER2 · 10.0 HSPF2
- Mainline ML33HP230LMNTH-O · cold climate17.7 SEER2 · 10.0 HSPF2
- Multi MFG HHS-36HD-A · cold climate17.6 SEER2 · 9.9 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 9, 2026. How we use the data.