4-ton central heat pump · 7SCP18V Series
Concord 7SCP18V60P-**A
Average cooling efficiency and very good heating efficiency for a 4-ton central heat pump, and certified for cold climates.
Ranks #87 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,324 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.0 Cooling efficiency over a seasonAverage · beats 66%
- HSPF2
- 9.6 Heating efficiency over a seasonVery good · beats 76%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 45,000 BTU/h88% of its 47°F outputBelow average · beats 27%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 45,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 76% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 573 certified pairings.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Concord |
| Also sold as | Ducane, ALLIED |
| Outdoor unit model | 7SCP18V60P-**A |
| Series | 7SCP18V Series |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 29, 2024 |
| Last certified | July 16, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.0 (range 15.2-18.0) |
| EER2Efficiency at 95°F outdoors | 9.6-11.7 |
| Cooling capacity | 42,500-55,500 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.1-9.6 |
| Capacity at 47°F | 47,000-56,500 BTU/h |
| Capacity at 17°F | 38,500-45,000 BTU/h |
| Capacity at 5°F | 39,000-45,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.75-1.95 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7AH1AV48PX- at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 573 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 7AH1AV48PX- · cold climate | - | 18.0 | 11.7 | 9.5 | 42,000 | 216013466 |
| 7AH1AV48PX- · cold climate | - | 18.0 | 11.7 | 9.5 | 42,000 | 216013470 |
| 7AH2AE48PX- · cold climate | - | 18.0 | 10.5 | 9.5 | 43,000 | 216705396 |
| 7AH2AE48PX- · cold climate | - | 18.0 | 10.5 | 9.5 | 43,000 | 216705403 |
| 7AH2AE48PX- · cold climate | - | 18.0 | 10.5 | 9.5 | 43,000 | 217509120 |
| 7AH1AV48PX- · cold climate | - | 18.0 | 11.7 | 9.5 | 42,000 | 217509073 |
| 7AH1RE42DX- · cold climate | - | 17.9 | 10.7 | 9.6 | 45,000 | 218636368 |
| 7AH1RE42DX- · cold climate | - | 17.9 | 10.7 | 9.6 | 45,000 | 218636359 |
| 7AH1RE42DX- · cold climate | - | 17.9 | 10.7 | 9.6 | 45,000 | 218636350 |
| 7AH1RE48DX- · cold climate | - | 17.9 | 10.8 | 9.4 | 44,500 | 218636369 |
| 7AH1RE48DX- · cold climate | - | 17.9 | 10.8 | 9.4 | 44,500 | 218636360 |
| 7AH1RE48DX- · cold climate | - | 17.9 | 10.8 | 9.4 | 44,500 | 218636351 |
| 7E[C,U]49CX-**+TDR · cold climate | 80G2UH110CV20* | 17.7 | 11.0 | 9.0 | 39,000 | 217189312 |
| 7E[C,U]49CX-**+TDR · cold climate | 80G2UH110CV20* | 17.7 | 11.0 | 9.0 | 39,000 | 217189572 |
| 7E[C,U]49CX-**+TDR · cold climate | 80G2UH110CV20* | 17.7 | 11.0 | 9.0 | 39,000 | 217509331 |
| 7AH1AE42PX- · cold climate | - | 17.6 | 10.5 | 9.0 | 43,000 | 216619128 |
| 7AH1AV42PX- · cold climate | - | 17.6 | 11.0 | 9.0 | 43,000 | 216619129 |
| 7AH1AV42PX- · cold climate | - | 17.6 | 11.0 | 9.0 | 43,000 | 216619080 |
| 7AH1AE42PX- · cold climate | - | 17.6 | 10.5 | 9.0 | 43,000 | 216619079 |
| 7AH1AE42PX- · cold climate | - | 17.6 | 10.5 | 9.0 | 43,000 | 217509087 |
| 7AH1AV42PX- · cold climate | - | 17.6 | 11.0 | 9.0 | 43,000 | 217509088 |
| 7E[C,U]49CX-**+TDR · cold climate | 92G1UH110CE16* | 17.6 | 11.0 | 9.0 | 39,000 | 217450695 |
| 7E[C,U]49CX-**+TDR · cold climate | 92G1UH110CE16* | 17.6 | 11.0 | 9.0 | 39,000 | 217450560 |
| 7E[C,U]49CX-**+TDR · cold climate | 92G1UH110CE16* | 17.6 | 11.0 | 9.0 | 39,000 | 217509501 |
| 7AH2AE42PX- · cold climate | - | 17.5 | 11.0 | 9.4 | 42,500 | 216705395 |
| 7AH2AE42PX- · cold climate | - | 17.5 | 11.0 | 9.4 | 42,500 | 216705402 |
| 7AH2AE42PX- · cold climate | - | 17.5 | 11.0 | 9.4 | 42,500 | 217509119 |
| 7AH1AE48PX- · cold climate | - | 17.5 | 11.0 | 9.0 | 43,000 | 216619130 |
| 7AH1AE48PX- · cold climate | - | 17.5 | 11.0 | 9.0 | 43,000 | 216619081 |
| 7AH1AE48PX- · cold climate | - | 17.5 | 11.0 | 9.0 | 43,000 | 217509089 |
| 7E[C,U]49CX-**+TDR · cold climate | 92G1UH090CE16* | 17.3 | 11.0 | 9.0 | 39,500 | 217450694 |
| 7E[C,U]49CX-**+TDR · cold climate | 92G1UH090CE16* | 17.3 | 11.0 | 9.0 | 39,500 | 217450559 |
| 7E[C,U]49CX-**+TDR · cold climate | 92G1UH090CE16* | 17.3 | 11.0 | 9.0 | 39,500 | 217509500 |
| 7ED48CX-**+TDR · cold climate | 96G1DF090CE16* | 17.3 | 10.0 | 9.0 | 39,000 | 217189602 |
| 7ED48CX-**+TDR · cold climate | 96G1DF090CE16* | 17.3 | 10.0 | 9.0 | 39,000 | 217189342 |
| 7ED48CX-**+TDR · cold climate | 92G1DF090CE16* | 17.3 | 10.0 | 9.0 | 39,000 | 217450582 |
| 7ED48CX-**+TDR · cold climate | 92G1DF090CE16* | 17.3 | 10.0 | 9.0 | 39,000 | 217450717 |
| 7ED48CX-**+TDR · cold climate | 92G1DF090CE16* | 17.3 | 10.0 | 9.0 | 39,000 | 217509523 |
| 7ED48CX-**+TDR · cold climate | 96G1DF090CE16* | 17.3 | 10.0 | 9.0 | 39,000 | 217509361 |
| 7E[C,U]49CX-**+TDR · cold climate | 97G2UH110CV20* | 17.2 | 10.0 | 9.0 | 39,500 | 216769774 |
| 7E[C,U]49CX-**+TDR · cold climate | 97G2UH110CV20* | 17.2 | 10.0 | 9.0 | 39,500 | 216769775 |
| 7E[C,U]49CX-**+TDR · cold climate | 80G1UH090CE20* | 17.2 | 11.0 | 9.0 | 39,500 | 217189316 |
| 7E[C,U]49CX-**+TDR · cold climate | 80G1UH110CE20* | 17.2 | 10.0 | 9.0 | 39,500 | 217189317 |
| 7E[C,U]49CX-**+TDR · cold climate | 80G1UH090CE20* | 17.2 | 11.0 | 9.0 | 39,500 | 217189576 |
| 7E[C,U]49CX-**+TDR · cold climate | 80G1UH110CE20* | 17.2 | 10.0 | 9.0 | 39,500 | 217189577 |
| 7E[C,U]49CX-**+TDR · cold climate | 97G2UH090CE16* | 17.2 | 11.0 | 9.0 | 39,000 | 217450693 |
| 7E[C,U]49CX-**+TDR · cold climate | 80G1UH110CE20L* | 17.2 | 10.0 | 9.0 | 39,500 | 217450696 |
| 7E[C,U]49CX-**+TDR · cold climate | 97G2UH090CE16* | 17.2 | 11.0 | 9.0 | 39,000 | 217450558 |
| 7E[C,U]49CX-**+TDR · cold climate | 80G1UH110CE20L* | 17.2 | 10.0 | 9.0 | 39,500 | 217450561 |
| 7E[C,U]49CX-**+TDR · cold climate | 97G2UH110CV20* | 17.2 | 10.0 | 9.0 | 39,500 | 217509142 |
| 7E[C,U]49CX-**+TDR · cold climate | 80G1UH110CE20L* | 17.2 | 10.0 | 9.0 | 39,500 | 217509502 |
| 7E[C,U]49CX-**+TDR · cold climate | 80G1UH090CE20* | 17.2 | 11.0 | 9.0 | 39,500 | 217509335 |
| 7E[C,U]49CX-**+TDR · cold climate | 80G1UH110CE20* | 17.2 | 10.0 | 9.0 | 39,500 | 217509336 |
| 7E[C,U]49CX-**+TDR · cold climate | 97G2UH090CE16* | 17.2 | 11.0 | 9.0 | 39,000 | 217509499 |
| 7ED48CX-**+TDR · cold climate | 80G1DF110CE20* | 17.2 | 11.0 | 9.0 | 39,000 | 217189603 |
| 7ED48CX-**+TDR · cold climate | 80G1DF110CE20* | 17.2 | 11.0 | 9.0 | 39,000 | 217189343 |
| 7ED48CX-**+TDR · cold climate | 80G1DF110CE20* | 17.2 | 11.0 | 9.0 | 39,000 | 217509362 |
| 7E[C,U]60CX-**+TDR · cold climate | 80G1UH090CE20* | 17.2 | 10.0 | 8.5 | 40,500 | 217189348 |
| 7E[C,U]60CX-**+TDR · cold climate | 80G1UH110CE20* | 17.2 | 10.0 | 8.5 | 40,500 | 217189349 |
| 7E[C,U]60CX-**+TDR · cold climate | 80G1UH090CE20* | 17.2 | 10.0 | 8.5 | 40,500 | 217189608 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,462/yr
- Miami, FL$1,188/yr
- Houston, TX$1,310/yr
- Atlanta, GA$1,324/yr
- Los Angeles, CA$1,288/yr
- New York, NY$3,162/yr
- Chicago, IL$2,567/yr
- Denver, CO$2,133/yr
- Seattle, WA$1,311/yr
- Minneapolis, MN$2,640/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Concord 7SCP18V60P-**A?
- The Concord 7SCP18V60P-**A is rated at up to 18.0 SEER2 and 11.7 EER2 for cooling and up to 9.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 573 certified matchups SEER2 ranges from 15.2-18.0.
- Is the Concord 7SCP18V60P-**A good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 45,000 BTU/h at 5°F with a COP of 1.95, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Concord 7SCP18V60P-**A cost to run per year?
- At its rated efficiency it costs about $1,188-$3,162 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,462 in Phoenix and $2,640 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Concord 7SCP18V60P-**A?
- ENERGY STAR lists 573 certified combinations for this outdoor unit. The highest-rated ones use 7AH1AV48PX-, 7AH2AE48PX-, 7AH1RE42DX-.
- What refrigerant does the Concord 7SCP18V60P-**A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- Trane 5TCV0X61A1 · cold climate18.0 SEER2 · 10.0 HSPF2
- Haier 1U60T3PE*HE · cold climate18.0 SEER2 · 9.5 HSPF2
- Sure RD18AY60AJVC · cold climate18.0 SEER2 · 10.0 HSPF2
- TCL H48SDH20XQC · cold climate18.0 SEER2 · 9.5 HSPF2
- Trane/American Standard 5HCL6048A1000A · cold climate18.1 SEER2 · 8.5 HSPF2
- Navien, Inc. NAZ17V6022A118.0 SEER2 · 9.3 HSPF2
- Trane 5TWV8X60A1 · cold climate18.1 SEER2 · 8.5 HSPF2
- Daikin DH7VSA6010A · cold climate18.0 SEER2 · 9.0 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.