HVAC Rated

48,000 BTU mini-split heat pump · Standard Multi

Daikin 5MXM48AVJU

Below average cooling and heating efficiency for a 48,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #83 of 146 48,000 BTU mini-splits for cooling efficiency, and costs about $1,297 a year to run in a mixed climate like Atlanta.

SEER2
20.0 Cooling efficiency over a season
Below average · beats 18%
HSPF2
9.5 Heating efficiency over a season
Below average · beats 24%
EER2
10.0 Cooling efficiency on a 95°F day
Below average · beats 5%
Heat at 5°F
34,000 BTU/h70% of its 47°F output
Below average · beats 27%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 34,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You mainly need heat - its HSPF2 is below average for mini-splits.

Calculate my running cost

Details

Specifications48,000 BTU, R-32
General
BrandDaikin
Outdoor unit model5MXM48AVJU
SeriesStandard Multi
TypeMini-split heat pump
Nominal size48,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceOctober 20, 2025
Last certifiedJanuary 14, 2026
Cooling
SEER2Seasonal efficiency, higher is better20.0 (range 17.3-20.0)
EER2Efficiency at 95°F outdoors9.1-10.0
Cooling capacity46,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.9-9.5
Capacity at 47°F47,000-48,500 BTU/h
Capacity at 17°F27,400-28,200 BTU/h
Capacity at 5°F33,000-34,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.82-1.90
ENERGY STAR cold climateYes
Heating output as it gets colder70% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:

Certified matchups2 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
- DAIKIN · cold climate20.010.09.534,000217747237
- DAIKIN · cold climate17.39.18.933,000218000907
Yearly running cost in 10 large cities$1,085-$3,161

At each state's average electricity price and the city's typical heating and cooling hours.

Questions4
What is the SEER2 rating of the Daikin 5MXM48AVJU?
The Daikin 5MXM48AVJU is rated at up to 20.0 SEER2 and 10.0 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 2 certified matchups SEER2 ranges from 17.3-20.0.
Is the Daikin 5MXM48AVJU good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 34,000 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
How much does the Daikin 5MXM48AVJU cost to run per year?
At its rated efficiency it costs about $1,085-$3,161 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,373 in Phoenix and $2,668 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
What refrigerant does the Daikin 5MXM48AVJU use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,381/yrYou save $1,031/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Daikin 5MXM48AVJU
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,381
Current system, per year
$2,413
You save per year
$1,031
Payback
17.0 years
Net after 10 years
-$7,186

Cooling $810Heating $572Electricity used: 8,634 kWhSaved vs. a minimum-efficiency heat pump: $475

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 48,000 BTU models

See all 146 48,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 14, 2026. How we use the data.