HVAC Rated

18,000 BTU mini-split heat pump · AURORA

Daikin RXT18AVJU

Below average cooling and heating efficiency for a 18,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #353 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $541 a year to run in a mixed climate like Atlanta.

SEER2
21.0 Cooling efficiency over a season
Below average · beats 30%
HSPF2
9.6 Heating efficiency over a season
Below average · beats 30%
EER2
12.0 Cooling efficiency on a 95°F day
Below average · beats 25%
Heat at 5°F
21,600 BTU/h100% of its 47°F output
Below average · beats 9%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 21,600 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You mainly need heat - its HSPF2 is below average for mini-splits.

Calculate my running cost

Details

Specifications18,000 BTU, R-32
General
BrandDaikin
Outdoor unit modelRXT18AVJU
SeriesAURORA
TypeMini-split heat pump
Nominal size18,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceSeptember 9, 2024
Last certifiedOctober 6, 2025
Cooling
SEER2Seasonal efficiency, higher is better21.0 (range 21.0)
EER2Efficiency at 95°F outdoors12.0
Cooling capacity18,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.6
Capacity at 47°F21,600 BTU/h
Capacity at 17°F15,200 BTU/h
Capacity at 5°F21,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80
ENERGY STAR cold climateYes
Heating output as it gets colder100% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FTXV18AVJU at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
FTXV18AVJU DAIKIN · cold climate21.012.09.621,600215389735
Yearly running cost in 10 large cities$407-$1,355

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Daikin RXT18AVJU?
The Daikin RXT18AVJU is rated at up to 21.0 SEER2 and 12.0 EER2 for cooling and up to 9.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Daikin RXT18AVJU good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 21,600 BTU/h at 5°F with a COP of 1.80, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the Daikin RXT18AVJU cost to run per year?
At its rated efficiency it costs about $407-$1,355 a year in electricity in large U.S. cities, depending on climate and local rates - for example $539 in Phoenix and $1,161 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Daikin RXT18AVJU?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses DAIKIN FTXV18AVJU.
What refrigerant does the Daikin RXT18AVJU use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $554/yrYou save $433/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Daikin RXT18AVJU
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$554
Current system, per year
$987
You save per year
$433
Payback
16.2 years
Net after 10 years
-$2,667

Cooling $302Heating $252Electricity used: 3,461 kWhSaved vs. a minimum-efficiency heat pump: $212

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 18,000 BTU models

See all 465 18,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 6, 2025. How we use the data.