4-ton central heat pump · VANTIX
Friedrich RD16AY60AJVC
Below average cooling and heating efficiency for a 4-ton central heat pump, and certified for cold climates.
Ranks #231 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,619 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 8.5 Heating efficiency over a seasonBelow average · beats 38%
- EER2
- 10.0 Cooling efficiency on a 95°F dayBelow average · beats 10%
- Heat at 5°F
- 31,000 BTU/h53% of its 47°F outputVery good · beats 76%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 31,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 23 certified pairings.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
Details
Specifications
| General | |
|---|---|
| Brand | Friedrich |
| Also sold as | RUSSELL, Sure, Ruud, Rheem |
| Outdoor unit model | RD16AY60AJVC |
| Series | VANTIX |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | Yes |
| On the market since | June 6, 2025 |
| Last certified | September 15, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 9.0-10.0 |
| Cooling capacity | 51,000-56,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.1-8.5 |
| Capacity at 47°F | 51,000-55,500 BTU/h |
| Capacity at 17°F | 36,800-37,000 BTU/h |
| Capacity at 5°F | 29,200-31,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.20 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with SHMVY6024SEACN at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| SHMVY6024SEACN | - | 16.0 | 10.0 | 8.1 | 29,200 | 217495943 |
| SHMVY6024SEACN | - | 16.0 | 10.0 | 8.1 | 29,200 | 217495939 |
| FRHMVY6024SEACN | - | 16.0 | 10.0 | 8.1 | 29,200 | 217495935 |
| RHMVY6024SEACN | - | 16.0 | 10.0 | 8.1 | 29,200 | 217495931 |
| RHMVY6024SEACN | - | 16.0 | 10.0 | 8.1 | 29,200 | 217495927 |
| TCFY6021STAAM · cold climate | S972V1005A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719634 |
| TCFY6021STAAM · cold climate | S972V1005A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719633 |
| TCFY6021STAAM · cold climate | S972V0855A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719632 |
| TCFY6021STAAM · cold climate | S972V0855A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719631 |
| TCFY6021STAAM · cold climate | S972V0705A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719630 |
| TCFY6021STAAM · cold climate | S972V0705A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719629 |
| RCFY6021STAAM · cold climate | R972V1005A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719628 |
| RCFY6021STAAM · cold climate | R972V1005A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719627 |
| RCFY6021STAAM · cold climate | R972V0855A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719626 |
| RCFY6021STAAM · cold climate | R972V0855A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719625 |
| RCFY6021STAAM · cold climate | R972V0705A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719624 |
| RCFY6021STAAM · cold climate | R972V0705A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719623 |
| TCFY6021STAAM · cold climate | FR972V1005A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719622 |
| RCFY6021STAAM · cold climate | FR972V1005A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719621 |
| TCFY6021STAAM · cold climate | FR972V0855A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719620 |
| RCFY6021STAAM · cold climate | FR972V0855A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719619 |
| TCFY6021STAAM · cold climate | FR972V0705A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719618 |
| RCFY6021STAAM · cold climate | FR972V0705A21UPS | 15.2 | 9.0 | 8.5 | 31,000 | 218719617 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,820/yr
- Miami, FL$1,495/yr
- Houston, TX$1,631/yr
- Atlanta, GA$1,619/yr
- Los Angeles, CA$1,568/yr
- New York, NY$3,831/yr
- Chicago, IL$3,103/yr
- Denver, CO$2,574/yr
- Seattle, WA$1,577/yr
- Minneapolis, MN$3,183/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Friedrich RD16AY60AJVC?
- The Friedrich RD16AY60AJVC is rated at up to 16.0 SEER2 and 10.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 23 certified matchups SEER2 ranges from 15.2-16.0.
- Is the Friedrich RD16AY60AJVC good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 31,000 BTU/h at 5°F with a COP of 2.20, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
- How much does the Friedrich RD16AY60AJVC cost to run per year?
- At its rated efficiency it costs about $1,495-$3,831 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,820 in Phoenix and $3,183 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Friedrich RD16AY60AJVC?
- ENERGY STAR lists 23 certified combinations for this outdoor unit. The highest-rated ones use SHMVY6024SEACN, FRHMVY6024SEACN, RHMVY6024SEACN.
- What refrigerant does the Friedrich RD16AY60AJVC use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- Coleman XH660E2S1116.0 SEER2 · 8.5 HSPF2
- InfinityLiving EZ-48-EHPB · cold climate16.0 SEER2 · 8.5 HSPF2
- Blueridge BMSAHS4816C · cold climate16.0 SEER2 · 8.5 HSPF2
- KEEN Home KEENSTDHP48AA · cold climate16.0 SEER2 · 8.5 HSPF2
- AproDr AHU19-48HN1-C · cold climate16.0 SEER2 · 8.5 HSPF2
- York YH660E2S1116.0 SEER2 · 8.5 HSPF2
- ZERO ZSOVA-60HDMB-USHH · cold climate16.0 SEER2 · 9.0 HSPF2
- Blueridge BNG1A60SCN · cold climate16.0 SEER2 · 8.1 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 15, 2026. How we use the data.