24,000 BTU mini-split heat pump · H-Series
Fujitsu AOUH24LUAS1
Average cooling efficiency and very good heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #94 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $566 a year to run in a mixed climate like Atlanta.
- SEER2
- 23.0 Cooling efficiency over a seasonAverage · beats 62%
- HSPF2
- 11.0 Heating efficiency over a seasonVery good · beats 75%
- EER2
- 12.6 Cooling efficiency on a 95°F dayAverage · beats 52%
- Heat at 5°F
- 23,600 BTU/h98% of its 47°F outputVery good · beats 72%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 23,600 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 75% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Fujitsu |
| Outdoor unit model | AOUH24LUAS1 |
| Series | H-Series |
| Type | Mini-split heat pump |
| Nominal size | 24,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | March 1, 2023 |
| Last certified | June 5, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 23.0 (range 18.5-23.0) |
| EER2Efficiency at 95°F outdoors | 11.7-12.6 |
| Cooling capacity | 24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.0-11.0 |
| Capacity at 47°F | 24,000 BTU/h |
| Capacity at 17°F | 17,500-18,700 BTU/h |
| Capacity at 5°F | 23,000-23,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.94-2.12 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with AUUH24LUAS at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| AUUH24LUAS FUJITSU · cold climate | 23.0 | 12.6 | 11.0 | 23,600 | 211078831 |
| ABUH24LUAS FUJITSU · cold climate | 21.5 | 12.3 | 10.5 | 23,600 | 211078836 |
| AMUG24LMAS FUJITSU · cold climate | 18.8 | 11.7 | 10.0 | 23,000 | 211078835 |
| ARUH24LUAS FUJITSU · cold climate | 18.5 | 11.7 | 10.0 | 23,200 | 211078834 |
Yearly running cost in 10 large cities
- Phoenix, AZ$613/yr
- Miami, FL$491/yr
- Houston, TX$549/yr
- Atlanta, GA$566/yr
- Los Angeles, CA$553/yr
- New York, NY$1,365/yr
- Chicago, IL$1,111/yr
- Denver, CO$925/yr
- Seattle, WA$570/yr
- Minneapolis, MN$1,146/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Fujitsu AOUH24LUAS1?
- The Fujitsu AOUH24LUAS1 is rated at up to 23.0 SEER2 and 12.6 EER2 for cooling and up to 11.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 18.5-23.0.
- Is the Fujitsu AOUH24LUAS1 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 23,600 BTU/h at 5°F with a COP of 2.12, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
- How much does the Fujitsu AOUH24LUAS1 cost to run per year?
- At its rated efficiency it costs about $491-$1,365 a year in electricity in large U.S. cities, depending on climate and local rates - for example $613 in Phoenix and $1,146 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Fujitsu AOUH24LUAS1?
- ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use FUJITSU AUUH24LUAS, FUJITSU ABUH24LUAS, FUJITSU AMUG24LMAS.
- What refrigerant does the Fujitsu AOUH24LUAS1 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 24,000 BTU models
- Midea MOD30-24HFN10-M1P · cold climate23.0 SEER2 · 11.7 HSPF2
- Mitsubishi Electric MXZ-SM36NL- · cold climate23.0 SEER2 · 11.0 HSPF2
- Midea MOD-24HFN10AE · cold climate23.0 SEER2 · 11.7 HSPF2
- Continental CDHAMBB-27-O · cold climate23.0 SEER2 · 10.5 HSPF2
- Midea MO1ES-H24B-2A · cold climate23.0 SEER2 · 11.7 HSPF2
- Bosch BMS500-AAS024-1CSXRD · cold climate23.0 SEER2 · 11.7 HSPF2
- GE Appliances 3G24ED2BE · cold climate23.0 SEER2 · 10.5 HSPF2
- AC Pro MHPC-H-024BSB · cold climate23.0 SEER2 · 11.7 HSPF2
See all 430 24,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 5, 2026. How we use the data.